Transient Study of Flow and Cavitation Inside a Bileaflet Mechanical Heart Valve
A mechanical heart valve (MHV) is an effective device to cure heart disease, which has the advantage of long life and high reliability. Due to the hemodynamic characteristics of blood, mechanical heart valves can lead to potential complications such as hemolysis, which have damage to the blood eleme...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2020-04-01
|
Series: | Applied Sciences |
Subjects: | |
Online Access: | https://www.mdpi.com/2076-3417/10/7/2548 |
id |
doaj-48eb6e3754084771be03471614c5260d |
---|---|
record_format |
Article |
spelling |
doaj-48eb6e3754084771be03471614c5260d2020-11-25T02:27:11ZengMDPI AGApplied Sciences2076-34172020-04-01102548254810.3390/app10072548Transient Study of Flow and Cavitation Inside a Bileaflet Mechanical Heart ValveWen-qing Li0Zhi-xin Gao1Zhi-jiang Jin2Jin-yuan Qian3Institute of Process Equipment, College of Energy Engineering, Zhejiang University, Hangzhou 310027, ChinaInstitute of Process Equipment, College of Energy Engineering, Zhejiang University, Hangzhou 310027, ChinaInstitute of Process Equipment, College of Energy Engineering, Zhejiang University, Hangzhou 310027, ChinaInstitute of Process Equipment, College of Energy Engineering, Zhejiang University, Hangzhou 310027, ChinaA mechanical heart valve (MHV) is an effective device to cure heart disease, which has the advantage of long life and high reliability. Due to the hemodynamic characteristics of blood, mechanical heart valves can lead to potential complications such as hemolysis, which have damage to the blood elements and thrombosis. In this paper, flowing features of the blood in the valve are analyzed and the cavitation mechanism in bileaflet mechanical heart valve (BMHV) is studied. Results show that the water hammer effect and the high-speed leakage flow effect are the primary causes of the cavitation in the valve. Compared with the high-speed leakage flow effect, the water hammer has a greater effect on the cavitation strength. The valve goes through four kinds of working condition within one heart beating period, including, fully opening stage, closing stage and fully closing stage. These four stages, respectively, make up 8.5%, 16.1%, 4.7% and 70.7% of the total period. The cavitation occurs on the fully closing stage. When the valve is in closing stage, the high pressure downstream of the valve lasts for about 20 ms and the high-speed leakage flow lasts for about 200 ms. This study systematically analyzes the causes of cavitation emerged in the process of periodic motion, which proposes the method for characterizing the intensity of the cavitation, and can be referred to for the cavitation suppression of the BHMV and similar valves.https://www.mdpi.com/2076-3417/10/7/2548cavitationbileaflet mechanical heart valveleakage flowwater hammer |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Wen-qing Li Zhi-xin Gao Zhi-jiang Jin Jin-yuan Qian |
spellingShingle |
Wen-qing Li Zhi-xin Gao Zhi-jiang Jin Jin-yuan Qian Transient Study of Flow and Cavitation Inside a Bileaflet Mechanical Heart Valve Applied Sciences cavitation bileaflet mechanical heart valve leakage flow water hammer |
author_facet |
Wen-qing Li Zhi-xin Gao Zhi-jiang Jin Jin-yuan Qian |
author_sort |
Wen-qing Li |
title |
Transient Study of Flow and Cavitation Inside a Bileaflet Mechanical Heart Valve |
title_short |
Transient Study of Flow and Cavitation Inside a Bileaflet Mechanical Heart Valve |
title_full |
Transient Study of Flow and Cavitation Inside a Bileaflet Mechanical Heart Valve |
title_fullStr |
Transient Study of Flow and Cavitation Inside a Bileaflet Mechanical Heart Valve |
title_full_unstemmed |
Transient Study of Flow and Cavitation Inside a Bileaflet Mechanical Heart Valve |
title_sort |
transient study of flow and cavitation inside a bileaflet mechanical heart valve |
publisher |
MDPI AG |
series |
Applied Sciences |
issn |
2076-3417 |
publishDate |
2020-04-01 |
description |
A mechanical heart valve (MHV) is an effective device to cure heart disease, which has the advantage of long life and high reliability. Due to the hemodynamic characteristics of blood, mechanical heart valves can lead to potential complications such as hemolysis, which have damage to the blood elements and thrombosis. In this paper, flowing features of the blood in the valve are analyzed and the cavitation mechanism in bileaflet mechanical heart valve (BMHV) is studied. Results show that the water hammer effect and the high-speed leakage flow effect are the primary causes of the cavitation in the valve. Compared with the high-speed leakage flow effect, the water hammer has a greater effect on the cavitation strength. The valve goes through four kinds of working condition within one heart beating period, including, fully opening stage, closing stage and fully closing stage. These four stages, respectively, make up 8.5%, 16.1%, 4.7% and 70.7% of the total period. The cavitation occurs on the fully closing stage. When the valve is in closing stage, the high pressure downstream of the valve lasts for about 20 ms and the high-speed leakage flow lasts for about 200 ms. This study systematically analyzes the causes of cavitation emerged in the process of periodic motion, which proposes the method for characterizing the intensity of the cavitation, and can be referred to for the cavitation suppression of the BHMV and similar valves. |
topic |
cavitation bileaflet mechanical heart valve leakage flow water hammer |
url |
https://www.mdpi.com/2076-3417/10/7/2548 |
work_keys_str_mv |
AT wenqingli transientstudyofflowandcavitationinsideabileafletmechanicalheartvalve AT zhixingao transientstudyofflowandcavitationinsideabileafletmechanicalheartvalve AT zhijiangjin transientstudyofflowandcavitationinsideabileafletmechanicalheartvalve AT jinyuanqian transientstudyofflowandcavitationinsideabileafletmechanicalheartvalve |
_version_ |
1724843777827274752 |