A method for verification of treatment times for high-dose-rate intraluminal brachytherapy treatment

<p>Purpose: This study was aimed to increase the quality of high dose rate (HDR) intraluminal brachytherapy treatment. For this purpose, an easy, fast and accurate patient-specific quality assurance (QA) tool has been developed. This tool has been implemented at Bahawalpur Institute of Nuclear...

Full description

Bibliographic Details
Main Authors: Muhammad Asghar Gadhi, Shahab Fatmi, Muhammad Shakil, Saeed Ahmad Buzdar
Format: Article
Language:English
Published: IJCTO 2016-06-01
Series:International Journal of Cancer Therapy and Oncology
Subjects:
Online Access:http://ijcto.org/index.php/IJCTO/article/view/462
id doaj-4969ea32e3a54497a77ac58376f5b2c1
record_format Article
spelling doaj-4969ea32e3a54497a77ac58376f5b2c12020-11-24T23:01:08ZengIJCTOInternational Journal of Cancer Therapy and Oncology 2330-40492016-06-014210.14319/ijcto.42.3259A method for verification of treatment times for high-dose-rate intraluminal brachytherapy treatmentMuhammad Asghar Gadhi0Shahab Fatmi1Muhammad Shakil2Saeed Ahmad Buzdar3Department of Medical Physics, Bahawalpur Institute of Nuclear Medicine and Oncology (BINO), BahawalpurDepartment of Nuclear Medicine, Bahawalpur Institute of Nuclear Medicine and Oncology (BINO), BahawalpurDepartment of Physics, University of Gujrat, GujratMedical Physics Research Group, Department of Physics, The Islamia University of Bahawalpur, Bahawalpur<p>Purpose: This study was aimed to increase the quality of high dose rate (HDR) intraluminal brachytherapy treatment. For this purpose, an easy, fast and accurate patient-specific quality assurance (QA) tool has been developed. This tool has been implemented at Bahawalpur Institute of Nuclear Medicine and Oncology (BINO), Bahawalpur, Pakistan.</p><p>Methods: ABACUS 3.1 Treatment planning system (TPS) has been used for treatment planning and calculation of total dwell time and then results were compared with the time calculated using the proposed method. This method has been used to verify the total dwell time for different rectum applicators for relevant treatment lengths (2-7 cm) and depths (1.5-2.5 cm), different oesophagus applicators of relevant treatment lengths (6-10 cm) and depths (0.9 &amp; 1.0 cm), and a bronchus applicator for relevant treatment lengths (4-7.5 cm) and depth (0.5 cm).</p><p>Results: The average percentage differences between treatment time T<sub>M </sub>with manual calculation and as calculated by the TPS is 0.32% (standard deviation 1.32%) for rectum, 0.24% (standard deviation 2.36%) for oesophagus and 1.96% (standard deviation 0.55%) for bronchus, respectively. These results advocate that the proposed method is valuable for independent verification of patient-specific treatment planning QA.</p><p>Conclusion: The technique illustrated in the current study is an easy, simple, quick and useful for independent verification of the total dwell time for HDR intraluminal brachytherapy. Our method is able to identify human error-related planning mistakes and to evaluate the quality of treatment planning. It enhances the quality of brachytherapy treatment and reliability of the system.</p>http://ijcto.org/index.php/IJCTO/article/view/462Intraluminal, Brachytherapy, Independent Method, High Dose Rate
collection DOAJ
language English
format Article
sources DOAJ
author Muhammad Asghar Gadhi
Shahab Fatmi
Muhammad Shakil
Saeed Ahmad Buzdar
spellingShingle Muhammad Asghar Gadhi
Shahab Fatmi
Muhammad Shakil
Saeed Ahmad Buzdar
A method for verification of treatment times for high-dose-rate intraluminal brachytherapy treatment
International Journal of Cancer Therapy and Oncology
Intraluminal, Brachytherapy, Independent Method, High Dose Rate
author_facet Muhammad Asghar Gadhi
Shahab Fatmi
Muhammad Shakil
Saeed Ahmad Buzdar
author_sort Muhammad Asghar Gadhi
title A method for verification of treatment times for high-dose-rate intraluminal brachytherapy treatment
title_short A method for verification of treatment times for high-dose-rate intraluminal brachytherapy treatment
title_full A method for verification of treatment times for high-dose-rate intraluminal brachytherapy treatment
title_fullStr A method for verification of treatment times for high-dose-rate intraluminal brachytherapy treatment
title_full_unstemmed A method for verification of treatment times for high-dose-rate intraluminal brachytherapy treatment
title_sort method for verification of treatment times for high-dose-rate intraluminal brachytherapy treatment
publisher IJCTO
series International Journal of Cancer Therapy and Oncology
issn 2330-4049
publishDate 2016-06-01
description <p>Purpose: This study was aimed to increase the quality of high dose rate (HDR) intraluminal brachytherapy treatment. For this purpose, an easy, fast and accurate patient-specific quality assurance (QA) tool has been developed. This tool has been implemented at Bahawalpur Institute of Nuclear Medicine and Oncology (BINO), Bahawalpur, Pakistan.</p><p>Methods: ABACUS 3.1 Treatment planning system (TPS) has been used for treatment planning and calculation of total dwell time and then results were compared with the time calculated using the proposed method. This method has been used to verify the total dwell time for different rectum applicators for relevant treatment lengths (2-7 cm) and depths (1.5-2.5 cm), different oesophagus applicators of relevant treatment lengths (6-10 cm) and depths (0.9 &amp; 1.0 cm), and a bronchus applicator for relevant treatment lengths (4-7.5 cm) and depth (0.5 cm).</p><p>Results: The average percentage differences between treatment time T<sub>M </sub>with manual calculation and as calculated by the TPS is 0.32% (standard deviation 1.32%) for rectum, 0.24% (standard deviation 2.36%) for oesophagus and 1.96% (standard deviation 0.55%) for bronchus, respectively. These results advocate that the proposed method is valuable for independent verification of patient-specific treatment planning QA.</p><p>Conclusion: The technique illustrated in the current study is an easy, simple, quick and useful for independent verification of the total dwell time for HDR intraluminal brachytherapy. Our method is able to identify human error-related planning mistakes and to evaluate the quality of treatment planning. It enhances the quality of brachytherapy treatment and reliability of the system.</p>
topic Intraluminal, Brachytherapy, Independent Method, High Dose Rate
url http://ijcto.org/index.php/IJCTO/article/view/462
work_keys_str_mv AT muhammadasghargadhi amethodforverificationoftreatmenttimesforhighdoserateintraluminalbrachytherapytreatment
AT shahabfatmi amethodforverificationoftreatmenttimesforhighdoserateintraluminalbrachytherapytreatment
AT muhammadshakil amethodforverificationoftreatmenttimesforhighdoserateintraluminalbrachytherapytreatment
AT saeedahmadbuzdar amethodforverificationoftreatmenttimesforhighdoserateintraluminalbrachytherapytreatment
AT muhammadasghargadhi methodforverificationoftreatmenttimesforhighdoserateintraluminalbrachytherapytreatment
AT shahabfatmi methodforverificationoftreatmenttimesforhighdoserateintraluminalbrachytherapytreatment
AT muhammadshakil methodforverificationoftreatmenttimesforhighdoserateintraluminalbrachytherapytreatment
AT saeedahmadbuzdar methodforverificationoftreatmenttimesforhighdoserateintraluminalbrachytherapytreatment
_version_ 1725640560185704448