Objective and subjective image quality with prospectively gated versus ECG-controlled tube current modulation using 256-slice computed tomographic angiography
Introduction: Radiation exposure is one of the major limitations of computed tomographic coronary angiography (CTA). The purpose of this study was to compare the objective and subjective image quality and radiation dose using prospective ECG gating (PGA) versus ECG-controlled tube current modulation...
Main Authors: | , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Saudi Heart Association
2015-10-01
|
Series: | Journal of the Saudi Heart Association |
Subjects: | |
Online Access: | http://www.sciencedirect.com/science/article/pii/S1016731515000317 |
id |
doaj-4994623e0baa48b3a4d601e8b430e694 |
---|---|
record_format |
Article |
spelling |
doaj-4994623e0baa48b3a4d601e8b430e6942020-11-25T02:53:10ZengSaudi Heart AssociationJournal of the Saudi Heart Association1016-73152015-10-0127425626310.1016/j.jsha.2015.03.009Objective and subjective image quality with prospectively gated versus ECG-controlled tube current modulation using 256-slice computed tomographic angiographyRami Abazid0Osama Smettei1Sawsan Sayed2Fahad Al Harby3Abdullah Al Habeeb4Hanaa Al Saqqa5Salma Mergania6Joseph B. Selvanayagam7Prince Sultan Cardiac Center, Qassim, PSCCQ, BuraydahPrince Sultan Cardiac Center, Qassim, PSCCQ, BuraydahPrince Sultan Cardiac Center, Qassim, PSCCQ, BuraydahKing Fahad Specialist Hospital, Qassim, BuraydahKing Fahad Specialist Hospital, Qassim, BuraydahKing Fahad Specialist Hospital, Qassim, BuraydahKing Fahad Specialist Hospital, Qassim, BuraydahDepartment of Cardiovascular Medicine, Flinders Medical Centre, Flinders University of South Australia, Flinders Drive, Bedford Park, Adelaide 5042, AustraliaIntroduction: Radiation exposure is one of the major limitations of computed tomographic coronary angiography (CTA). The purpose of this study was to compare the objective and subjective image quality and radiation dose using prospective ECG gating (PGA) versus ECG-controlled tube current modulation (ECTCM) scanning techniques. Methods: A prospective, single-center study was performed at Prince Sultan Cardiac Centre, Qassim, Saudi Arabia. A total of 104 patients with low-to- intermediate probability of coronary artery disease (CAD) underwent CTA with either PGA or ECTCM acquisition. PGA was performed during the study period and compared with the last 50 CTAs previously done using ECTCM. A 4-point scale was used to assess the image quality subjectively. Objective image quality was assessed using image signal, noise, and signal-to-noise ratio (SNR). Results: Patient‘s Baseline characteristics were not different between the two scanning protocols. The 4-point score of subjective image quality showed no significant differences between the PGA and ECTCM scans (2.9 ± 0.7, 2.96 ± 0.7, respectively; p = 0.87). The objective image quality showed significantly higher noise and lower SNR with PGA compared with ECTCM (31 ± 9, 27 ± 9, respectively; p < 0.001 for noise) and (15 ± 5, 17 ± 7, respectively; p < 0.001 for SNR), with no statistical difference in the image signal (434 ± 123, 425 ± 103 HU, respectively, p = 0.7). Radiation exposure was significantly lower with PGA than with ECTCM. The dose-length product (DLP) for PGA was 334 ± 130 mGy, compared with 822 ± 286 mGy for the ECTCM. This corresponds to a 59% reduction in radiation exposure (p < 0.0001). Conclusions: Although prospective ECG-triggered axial scanning increased image noise, it maintained subjective image quality and was associated with a 59% reduction in radiation exposure when compared with ECTCM.http://www.sciencedirect.com/science/article/pii/S1016731515000317Image noiseRadiation exposureCoronary angiography |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Rami Abazid Osama Smettei Sawsan Sayed Fahad Al Harby Abdullah Al Habeeb Hanaa Al Saqqa Salma Mergania Joseph B. Selvanayagam |
spellingShingle |
Rami Abazid Osama Smettei Sawsan Sayed Fahad Al Harby Abdullah Al Habeeb Hanaa Al Saqqa Salma Mergania Joseph B. Selvanayagam Objective and subjective image quality with prospectively gated versus ECG-controlled tube current modulation using 256-slice computed tomographic angiography Journal of the Saudi Heart Association Image noise Radiation exposure Coronary angiography |
author_facet |
Rami Abazid Osama Smettei Sawsan Sayed Fahad Al Harby Abdullah Al Habeeb Hanaa Al Saqqa Salma Mergania Joseph B. Selvanayagam |
author_sort |
Rami Abazid |
title |
Objective and subjective image quality with prospectively gated versus ECG-controlled tube current modulation using 256-slice computed tomographic angiography |
title_short |
Objective and subjective image quality with prospectively gated versus ECG-controlled tube current modulation using 256-slice computed tomographic angiography |
title_full |
Objective and subjective image quality with prospectively gated versus ECG-controlled tube current modulation using 256-slice computed tomographic angiography |
title_fullStr |
Objective and subjective image quality with prospectively gated versus ECG-controlled tube current modulation using 256-slice computed tomographic angiography |
title_full_unstemmed |
Objective and subjective image quality with prospectively gated versus ECG-controlled tube current modulation using 256-slice computed tomographic angiography |
title_sort |
objective and subjective image quality with prospectively gated versus ecg-controlled tube current modulation using 256-slice computed tomographic angiography |
publisher |
Saudi Heart Association |
series |
Journal of the Saudi Heart Association |
issn |
1016-7315 |
publishDate |
2015-10-01 |
description |
Introduction: Radiation exposure is one of the major limitations of computed tomographic coronary angiography (CTA). The purpose of this study was to compare the objective and subjective image quality and radiation dose using prospective ECG gating (PGA) versus ECG-controlled tube current modulation (ECTCM) scanning techniques.
Methods: A prospective, single-center study was performed at Prince Sultan Cardiac Centre, Qassim, Saudi Arabia. A total of 104 patients with low-to- intermediate probability of coronary artery disease (CAD) underwent CTA with either PGA or ECTCM acquisition. PGA was performed during the study period and compared with the last 50 CTAs previously done using ECTCM. A 4-point scale was used to assess the image quality subjectively. Objective image quality was assessed using image signal, noise, and signal-to-noise ratio (SNR).
Results: Patient‘s Baseline characteristics were not different between the two scanning protocols. The 4-point score of subjective image quality showed no significant differences between the PGA and ECTCM scans (2.9 ± 0.7, 2.96 ± 0.7, respectively; p = 0.87). The objective image quality showed significantly higher noise and lower SNR with PGA compared with ECTCM (31 ± 9, 27 ± 9, respectively; p < 0.001 for noise) and (15 ± 5, 17 ± 7, respectively; p < 0.001 for SNR), with no statistical difference in the image signal (434 ± 123, 425 ± 103 HU, respectively, p = 0.7).
Radiation exposure was significantly lower with PGA than with ECTCM. The dose-length product (DLP) for PGA was 334 ± 130 mGy, compared with 822 ± 286 mGy for the ECTCM. This corresponds to a 59% reduction in radiation exposure (p < 0.0001).
Conclusions: Although prospective ECG-triggered axial scanning increased image noise, it maintained subjective image quality and was associated with a 59% reduction in radiation exposure when compared with ECTCM. |
topic |
Image noise Radiation exposure Coronary angiography |
url |
http://www.sciencedirect.com/science/article/pii/S1016731515000317 |
work_keys_str_mv |
AT ramiabazid objectiveandsubjectiveimagequalitywithprospectivelygatedversusecgcontrolledtubecurrentmodulationusing256slicecomputedtomographicangiography AT osamasmettei objectiveandsubjectiveimagequalitywithprospectivelygatedversusecgcontrolledtubecurrentmodulationusing256slicecomputedtomographicangiography AT sawsansayed objectiveandsubjectiveimagequalitywithprospectivelygatedversusecgcontrolledtubecurrentmodulationusing256slicecomputedtomographicangiography AT fahadalharby objectiveandsubjectiveimagequalitywithprospectivelygatedversusecgcontrolledtubecurrentmodulationusing256slicecomputedtomographicangiography AT abdullahalhabeeb objectiveandsubjectiveimagequalitywithprospectivelygatedversusecgcontrolledtubecurrentmodulationusing256slicecomputedtomographicangiography AT hanaaalsaqqa objectiveandsubjectiveimagequalitywithprospectivelygatedversusecgcontrolledtubecurrentmodulationusing256slicecomputedtomographicangiography AT salmamergania objectiveandsubjectiveimagequalitywithprospectivelygatedversusecgcontrolledtubecurrentmodulationusing256slicecomputedtomographicangiography AT josephbselvanayagam objectiveandsubjectiveimagequalitywithprospectivelygatedversusecgcontrolledtubecurrentmodulationusing256slicecomputedtomographicangiography |