Design and evaluation of a hybrid radiofrequency applicator for magnetic resonance imaging and RF induced hyperthermia: electromagnetic field simulations up to 14.0 Tesla and proof-of-concept at 7.0 Tesla.

This work demonstrates the feasibility of a hybrid radiofrequency (RF) applicator that supports magnetic resonance (MR) imaging and MR controlled targeted RF heating at ultrahigh magnetic fields (B0≥7.0T). For this purpose a virtual and an experimental configuration of an 8-channel transmit/receive...

Full description

Bibliographic Details
Main Authors: Lukas Winter, Celal Özerdem, Werner Hoffmann, Davide Santoro, Alexander Müller, Helmar Waiczies, Reiner Seemann, Andreas Graessl, Peter Wust, Thoralf Niendorf
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2013-01-01
Series:PLoS ONE
Online Access:http://europepmc.org/articles/PMC3632575?pdf=render
id doaj-4b738d1b06174222832b473efca8e8ed
record_format Article
spelling doaj-4b738d1b06174222832b473efca8e8ed2020-11-25T02:15:31ZengPublic Library of Science (PLoS)PLoS ONE1932-62032013-01-0184e6166110.1371/journal.pone.0061661Design and evaluation of a hybrid radiofrequency applicator for magnetic resonance imaging and RF induced hyperthermia: electromagnetic field simulations up to 14.0 Tesla and proof-of-concept at 7.0 Tesla.Lukas WinterCelal ÖzerdemWerner HoffmannDavide SantoroAlexander MüllerHelmar WaicziesReiner SeemannAndreas GraesslPeter WustThoralf NiendorfThis work demonstrates the feasibility of a hybrid radiofrequency (RF) applicator that supports magnetic resonance (MR) imaging and MR controlled targeted RF heating at ultrahigh magnetic fields (B0≥7.0T). For this purpose a virtual and an experimental configuration of an 8-channel transmit/receive (TX/RX) hybrid RF applicator was designed. For TX/RX bow tie antenna electric dipoles were employed. Electromagnetic field simulations (EMF) were performed to study RF heating versus RF wavelength (frequency range: 64 MHz (1.5T) to 600 MHz (14.0T)). The experimental version of the applicator was implemented at B0 = 7.0T. The applicators feasibility for targeted RF heating was evaluated in EMF simulations and in phantom studies. Temperature co-simulations were conducted in phantoms and in a human voxel model. Our results demonstrate that higher frequencies afford a reduction in the size of specific absorption rate (SAR) hotspots. At 7T (298 MHz) the hybrid applicator yielded a 50% iso-contour SAR (iso-SAR-50%) hotspot with a diameter of 43 mm. At 600 MHz an iso-SAR-50% hotspot of 26 mm in diameter was observed. RF power deposition per RF input power was found to increase with B0 which makes targeted RF heating more efficient at higher frequencies. The applicator was capable of generating deep-seated temperature hotspots in phantoms. The feasibility of 2D steering of a SAR/temperature hotspot to a target location was demonstrated by the induction of a focal temperature increase (ΔT = 8.1 K) in an off-center region of the phantom. Temperature simulations in the human brain performed at 298 MHz showed a maximum temperature increase to 48.6C for a deep-seated hotspot in the brain with a size of (19×23×32)mm(3) iso-temperature-90%. The hybrid applicator provided imaging capabilities that facilitate high spatial resolution brain MRI. To conclude, this study outlines the technical underpinnings and demonstrates the basic feasibility of an 8-channel hybrid TX/RX applicator that supports MR imaging, MR thermometry and targeted RF heating in one device.http://europepmc.org/articles/PMC3632575?pdf=render
collection DOAJ
language English
format Article
sources DOAJ
author Lukas Winter
Celal Özerdem
Werner Hoffmann
Davide Santoro
Alexander Müller
Helmar Waiczies
Reiner Seemann
Andreas Graessl
Peter Wust
Thoralf Niendorf
spellingShingle Lukas Winter
Celal Özerdem
Werner Hoffmann
Davide Santoro
Alexander Müller
Helmar Waiczies
Reiner Seemann
Andreas Graessl
Peter Wust
Thoralf Niendorf
Design and evaluation of a hybrid radiofrequency applicator for magnetic resonance imaging and RF induced hyperthermia: electromagnetic field simulations up to 14.0 Tesla and proof-of-concept at 7.0 Tesla.
PLoS ONE
author_facet Lukas Winter
Celal Özerdem
Werner Hoffmann
Davide Santoro
Alexander Müller
Helmar Waiczies
Reiner Seemann
Andreas Graessl
Peter Wust
Thoralf Niendorf
author_sort Lukas Winter
title Design and evaluation of a hybrid radiofrequency applicator for magnetic resonance imaging and RF induced hyperthermia: electromagnetic field simulations up to 14.0 Tesla and proof-of-concept at 7.0 Tesla.
title_short Design and evaluation of a hybrid radiofrequency applicator for magnetic resonance imaging and RF induced hyperthermia: electromagnetic field simulations up to 14.0 Tesla and proof-of-concept at 7.0 Tesla.
title_full Design and evaluation of a hybrid radiofrequency applicator for magnetic resonance imaging and RF induced hyperthermia: electromagnetic field simulations up to 14.0 Tesla and proof-of-concept at 7.0 Tesla.
title_fullStr Design and evaluation of a hybrid radiofrequency applicator for magnetic resonance imaging and RF induced hyperthermia: electromagnetic field simulations up to 14.0 Tesla and proof-of-concept at 7.0 Tesla.
title_full_unstemmed Design and evaluation of a hybrid radiofrequency applicator for magnetic resonance imaging and RF induced hyperthermia: electromagnetic field simulations up to 14.0 Tesla and proof-of-concept at 7.0 Tesla.
title_sort design and evaluation of a hybrid radiofrequency applicator for magnetic resonance imaging and rf induced hyperthermia: electromagnetic field simulations up to 14.0 tesla and proof-of-concept at 7.0 tesla.
publisher Public Library of Science (PLoS)
series PLoS ONE
issn 1932-6203
publishDate 2013-01-01
description This work demonstrates the feasibility of a hybrid radiofrequency (RF) applicator that supports magnetic resonance (MR) imaging and MR controlled targeted RF heating at ultrahigh magnetic fields (B0≥7.0T). For this purpose a virtual and an experimental configuration of an 8-channel transmit/receive (TX/RX) hybrid RF applicator was designed. For TX/RX bow tie antenna electric dipoles were employed. Electromagnetic field simulations (EMF) were performed to study RF heating versus RF wavelength (frequency range: 64 MHz (1.5T) to 600 MHz (14.0T)). The experimental version of the applicator was implemented at B0 = 7.0T. The applicators feasibility for targeted RF heating was evaluated in EMF simulations and in phantom studies. Temperature co-simulations were conducted in phantoms and in a human voxel model. Our results demonstrate that higher frequencies afford a reduction in the size of specific absorption rate (SAR) hotspots. At 7T (298 MHz) the hybrid applicator yielded a 50% iso-contour SAR (iso-SAR-50%) hotspot with a diameter of 43 mm. At 600 MHz an iso-SAR-50% hotspot of 26 mm in diameter was observed. RF power deposition per RF input power was found to increase with B0 which makes targeted RF heating more efficient at higher frequencies. The applicator was capable of generating deep-seated temperature hotspots in phantoms. The feasibility of 2D steering of a SAR/temperature hotspot to a target location was demonstrated by the induction of a focal temperature increase (ΔT = 8.1 K) in an off-center region of the phantom. Temperature simulations in the human brain performed at 298 MHz showed a maximum temperature increase to 48.6C for a deep-seated hotspot in the brain with a size of (19×23×32)mm(3) iso-temperature-90%. The hybrid applicator provided imaging capabilities that facilitate high spatial resolution brain MRI. To conclude, this study outlines the technical underpinnings and demonstrates the basic feasibility of an 8-channel hybrid TX/RX applicator that supports MR imaging, MR thermometry and targeted RF heating in one device.
url http://europepmc.org/articles/PMC3632575?pdf=render
work_keys_str_mv AT lukaswinter designandevaluationofahybridradiofrequencyapplicatorformagneticresonanceimagingandrfinducedhyperthermiaelectromagneticfieldsimulationsupto140teslaandproofofconceptat70tesla
AT celalozerdem designandevaluationofahybridradiofrequencyapplicatorformagneticresonanceimagingandrfinducedhyperthermiaelectromagneticfieldsimulationsupto140teslaandproofofconceptat70tesla
AT wernerhoffmann designandevaluationofahybridradiofrequencyapplicatorformagneticresonanceimagingandrfinducedhyperthermiaelectromagneticfieldsimulationsupto140teslaandproofofconceptat70tesla
AT davidesantoro designandevaluationofahybridradiofrequencyapplicatorformagneticresonanceimagingandrfinducedhyperthermiaelectromagneticfieldsimulationsupto140teslaandproofofconceptat70tesla
AT alexandermuller designandevaluationofahybridradiofrequencyapplicatorformagneticresonanceimagingandrfinducedhyperthermiaelectromagneticfieldsimulationsupto140teslaandproofofconceptat70tesla
AT helmarwaiczies designandevaluationofahybridradiofrequencyapplicatorformagneticresonanceimagingandrfinducedhyperthermiaelectromagneticfieldsimulationsupto140teslaandproofofconceptat70tesla
AT reinerseemann designandevaluationofahybridradiofrequencyapplicatorformagneticresonanceimagingandrfinducedhyperthermiaelectromagneticfieldsimulationsupto140teslaandproofofconceptat70tesla
AT andreasgraessl designandevaluationofahybridradiofrequencyapplicatorformagneticresonanceimagingandrfinducedhyperthermiaelectromagneticfieldsimulationsupto140teslaandproofofconceptat70tesla
AT peterwust designandevaluationofahybridradiofrequencyapplicatorformagneticresonanceimagingandrfinducedhyperthermiaelectromagneticfieldsimulationsupto140teslaandproofofconceptat70tesla
AT thoralfniendorf designandevaluationofahybridradiofrequencyapplicatorformagneticresonanceimagingandrfinducedhyperthermiaelectromagneticfieldsimulationsupto140teslaandproofofconceptat70tesla
_version_ 1724895785700556800