Low Power Upconversion Mixer for Medical Remote Sensing
This work presents the design of a low power upconversion mixer adapted in medical remote sensing such as wireless endoscopy application. The proposed upconversion mixer operates in ISM band of 433 MHz. With the carrier power of −5 dBm, the proposed mixer has an output inferred 1 dB compression poin...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Hindawi Limited
2014-01-01
|
Series: | The Scientific World Journal |
Online Access: | http://dx.doi.org/10.1155/2014/923893 |
id |
doaj-4c2ee82c953943079f0eb6eb39939cd5 |
---|---|
record_format |
Article |
spelling |
doaj-4c2ee82c953943079f0eb6eb39939cd52020-11-25T01:11:09ZengHindawi LimitedThe Scientific World Journal2356-61401537-744X2014-01-01201410.1155/2014/923893923893Low Power Upconversion Mixer for Medical Remote SensingDe Xing Lioe0Suhaidi Shafie1Harikrishnan Ramiah2Gim Heng Tan3Department of Electrical and Electronics Engineering, Faculty of Engineering, Universiti Putra Malaysia, 43400 Serdang, Selangor, MalaysiaDepartment of Electrical and Electronics Engineering, Faculty of Engineering, Universiti Putra Malaysia, 43400 Serdang, Selangor, MalaysiaDepartment of Electrical Engineering, Faculty of Engineering, University of Malaya, 50603 Kuala Lumpur, MalaysiaDepartment of Electrical and Electronics Engineering, Faculty of Engineering, Universiti Putra Malaysia, 43400 Serdang, Selangor, MalaysiaThis work presents the design of a low power upconversion mixer adapted in medical remote sensing such as wireless endoscopy application. The proposed upconversion mixer operates in ISM band of 433 MHz. With the carrier power of −5 dBm, the proposed mixer has an output inferred 1 dB compression point of −0.5 dBm with a corresponding output third-order intercept point (OIP3) of 7.1 dBm. The design of the upconversion mixer is realized on CMOS 0.13 μm platform, with a current consumption of 594 μA at supply voltage headroom of 1.2 V.http://dx.doi.org/10.1155/2014/923893 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
De Xing Lioe Suhaidi Shafie Harikrishnan Ramiah Gim Heng Tan |
spellingShingle |
De Xing Lioe Suhaidi Shafie Harikrishnan Ramiah Gim Heng Tan Low Power Upconversion Mixer for Medical Remote Sensing The Scientific World Journal |
author_facet |
De Xing Lioe Suhaidi Shafie Harikrishnan Ramiah Gim Heng Tan |
author_sort |
De Xing Lioe |
title |
Low Power Upconversion Mixer for Medical Remote Sensing |
title_short |
Low Power Upconversion Mixer for Medical Remote Sensing |
title_full |
Low Power Upconversion Mixer for Medical Remote Sensing |
title_fullStr |
Low Power Upconversion Mixer for Medical Remote Sensing |
title_full_unstemmed |
Low Power Upconversion Mixer for Medical Remote Sensing |
title_sort |
low power upconversion mixer for medical remote sensing |
publisher |
Hindawi Limited |
series |
The Scientific World Journal |
issn |
2356-6140 1537-744X |
publishDate |
2014-01-01 |
description |
This work presents the design of a low power upconversion mixer adapted in medical remote sensing such as wireless endoscopy application. The proposed upconversion mixer operates in ISM band of 433 MHz. With the carrier power of −5 dBm, the proposed mixer has an output inferred 1 dB compression point of −0.5 dBm with a corresponding output third-order intercept point (OIP3) of 7.1 dBm. The design of the upconversion mixer is realized on CMOS 0.13 μm platform, with a current consumption of 594 μA at supply voltage headroom of 1.2 V. |
url |
http://dx.doi.org/10.1155/2014/923893 |
work_keys_str_mv |
AT dexinglioe lowpowerupconversionmixerformedicalremotesensing AT suhaidishafie lowpowerupconversionmixerformedicalremotesensing AT harikrishnanramiah lowpowerupconversionmixerformedicalremotesensing AT gimhengtan lowpowerupconversionmixerformedicalremotesensing |
_version_ |
1725172651928846336 |