Low Power Upconversion Mixer for Medical Remote Sensing

This work presents the design of a low power upconversion mixer adapted in medical remote sensing such as wireless endoscopy application. The proposed upconversion mixer operates in ISM band of 433 MHz. With the carrier power of −5 dBm, the proposed mixer has an output inferred 1 dB compression poin...

Full description

Bibliographic Details
Main Authors: De Xing Lioe, Suhaidi Shafie, Harikrishnan Ramiah, Gim Heng Tan
Format: Article
Language:English
Published: Hindawi Limited 2014-01-01
Series:The Scientific World Journal
Online Access:http://dx.doi.org/10.1155/2014/923893
id doaj-4c2ee82c953943079f0eb6eb39939cd5
record_format Article
spelling doaj-4c2ee82c953943079f0eb6eb39939cd52020-11-25T01:11:09ZengHindawi LimitedThe Scientific World Journal2356-61401537-744X2014-01-01201410.1155/2014/923893923893Low Power Upconversion Mixer for Medical Remote SensingDe Xing Lioe0Suhaidi Shafie1Harikrishnan Ramiah2Gim Heng Tan3Department of Electrical and Electronics Engineering, Faculty of Engineering, Universiti Putra Malaysia, 43400 Serdang, Selangor, MalaysiaDepartment of Electrical and Electronics Engineering, Faculty of Engineering, Universiti Putra Malaysia, 43400 Serdang, Selangor, MalaysiaDepartment of Electrical Engineering, Faculty of Engineering, University of Malaya, 50603 Kuala Lumpur, MalaysiaDepartment of Electrical and Electronics Engineering, Faculty of Engineering, Universiti Putra Malaysia, 43400 Serdang, Selangor, MalaysiaThis work presents the design of a low power upconversion mixer adapted in medical remote sensing such as wireless endoscopy application. The proposed upconversion mixer operates in ISM band of 433 MHz. With the carrier power of −5 dBm, the proposed mixer has an output inferred 1 dB compression point of −0.5 dBm with a corresponding output third-order intercept point (OIP3) of 7.1 dBm. The design of the upconversion mixer is realized on CMOS 0.13 μm platform, with a current consumption of 594 μA at supply voltage headroom of 1.2 V.http://dx.doi.org/10.1155/2014/923893
collection DOAJ
language English
format Article
sources DOAJ
author De Xing Lioe
Suhaidi Shafie
Harikrishnan Ramiah
Gim Heng Tan
spellingShingle De Xing Lioe
Suhaidi Shafie
Harikrishnan Ramiah
Gim Heng Tan
Low Power Upconversion Mixer for Medical Remote Sensing
The Scientific World Journal
author_facet De Xing Lioe
Suhaidi Shafie
Harikrishnan Ramiah
Gim Heng Tan
author_sort De Xing Lioe
title Low Power Upconversion Mixer for Medical Remote Sensing
title_short Low Power Upconversion Mixer for Medical Remote Sensing
title_full Low Power Upconversion Mixer for Medical Remote Sensing
title_fullStr Low Power Upconversion Mixer for Medical Remote Sensing
title_full_unstemmed Low Power Upconversion Mixer for Medical Remote Sensing
title_sort low power upconversion mixer for medical remote sensing
publisher Hindawi Limited
series The Scientific World Journal
issn 2356-6140
1537-744X
publishDate 2014-01-01
description This work presents the design of a low power upconversion mixer adapted in medical remote sensing such as wireless endoscopy application. The proposed upconversion mixer operates in ISM band of 433 MHz. With the carrier power of −5 dBm, the proposed mixer has an output inferred 1 dB compression point of −0.5 dBm with a corresponding output third-order intercept point (OIP3) of 7.1 dBm. The design of the upconversion mixer is realized on CMOS 0.13 μm platform, with a current consumption of 594 μA at supply voltage headroom of 1.2 V.
url http://dx.doi.org/10.1155/2014/923893
work_keys_str_mv AT dexinglioe lowpowerupconversionmixerformedicalremotesensing
AT suhaidishafie lowpowerupconversionmixerformedicalremotesensing
AT harikrishnanramiah lowpowerupconversionmixerformedicalremotesensing
AT gimhengtan lowpowerupconversionmixerformedicalremotesensing
_version_ 1725172651928846336