Analysis of Lack of Fusion in Welds at Water Heaters

The paper treats a weld discontinuity called lack of fusion, which is frequently a cause of leakage of a water heater. The heater was produced by MAG welding using two wires (twin arc welding). The paper states some reasons for the occurrence of lack of fusion, i.e. the arc blow effect, an inappropr...