AN LC- MS/MS METHOD FOR THE DETERMINATION OF OMEPRAZOLE ON PROTON PUMP INHIBITOR IN HUMAN PLASMA
A sensitive and selective liquid chromatographic method coupled with tandem mass spectroscopy (LC-MS/MS) was developed for the quantification of omeprazole in human plasma. Lansoprazole was used as internal standard with plasma samples, extracted using 10mM ammonium acetate. A centrifuged upper laye...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Universitas Gadjah Mada
2016-04-01
|
Series: | Indonesian Journal of Pharmacy |
Subjects: | |
Online Access: | http://indonesianjpharm.farmasi.ugm.ac.id/index.php/3/article/view/1062 |
id |
doaj-4d75bb498b1f45dfafe24f8e014f5a4f |
---|---|
record_format |
Article |
spelling |
doaj-4d75bb498b1f45dfafe24f8e014f5a4f2020-11-25T00:55:35ZengUniversitas Gadjah MadaIndonesian Journal of Pharmacy2338-94272338-94862016-04-01272809110.14499/indonesianjpharm27iss2pp80AN LC- MS/MS METHOD FOR THE DETERMINATION OF OMEPRAZOLE ON PROTON PUMP INHIBITOR IN HUMAN PLASMAT. Sudha 0Kalan Kumar Reddy1P. V. Hemalatha2V. R. Ravikumar3Dept Pharma. Analysis, The Erode College of Pharmacy, Erode TamilNadu, India. 638112.Dept Pharma. Analysis, The Erode College of Pharmacy, Erode TamilNadu, India. 638112.Dept Pharm. Chemistry, The Erode College of Pharmacy, Erode Tamil- Nadu, India. 638112.Dept Pharmacognosy, The Erode College of Pharmacy, Erode, TamilNadu, India. 638112.A sensitive and selective liquid chromatographic method coupled with tandem mass spectroscopy (LC-MS/MS) was developed for the quantification of omeprazole in human plasma. Lansoprazole was used as internal standard with plasma samples, extracted using 10mM ammonium acetate. A centrifuged upper layer was then evaporated and reconstituted with Acetonitrile: mobile phase buffer 70:30%v/v. The reconstructed samples were injected into a C18 column purospher star 5µ. The mobile phase was composed of ACN: mobile phase buffer (5mm ammonium bicarbonate buffer) in the ratio of 70:30%v/v with flow rate 1.0mL/min. The mass spectrometer was operated using positive ion mode and turbo electro spray ionisation. Nitrogen was used as the nebulizer, curtain, collision and auxiliary gases. Using MS/MS with multiple reactions monitoring (MRM) mode, omeprazole was detected without severe interferences from plasma matrix. Detection of omeprazole in human plasma was accurate and precision. This method has been successfully applied to the study of omeprazole in human specimenshttp://indonesianjpharm.farmasi.ugm.ac.id/index.php/3/article/view/1062Proton pump inhibitoromeprazolelansoprazoleLC-MS/MSliquid liquid extraction |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
T. Sudha Kalan Kumar Reddy P. V. Hemalatha V. R. Ravikumar |
spellingShingle |
T. Sudha Kalan Kumar Reddy P. V. Hemalatha V. R. Ravikumar AN LC- MS/MS METHOD FOR THE DETERMINATION OF OMEPRAZOLE ON PROTON PUMP INHIBITOR IN HUMAN PLASMA Indonesian Journal of Pharmacy Proton pump inhibitor omeprazole lansoprazole LC-MS/MS liquid liquid extraction |
author_facet |
T. Sudha Kalan Kumar Reddy P. V. Hemalatha V. R. Ravikumar |
author_sort |
T. Sudha |
title |
AN LC- MS/MS METHOD FOR THE DETERMINATION OF OMEPRAZOLE ON PROTON PUMP INHIBITOR IN HUMAN PLASMA |
title_short |
AN LC- MS/MS METHOD FOR THE DETERMINATION OF OMEPRAZOLE ON PROTON PUMP INHIBITOR IN HUMAN PLASMA |
title_full |
AN LC- MS/MS METHOD FOR THE DETERMINATION OF OMEPRAZOLE ON PROTON PUMP INHIBITOR IN HUMAN PLASMA |
title_fullStr |
AN LC- MS/MS METHOD FOR THE DETERMINATION OF OMEPRAZOLE ON PROTON PUMP INHIBITOR IN HUMAN PLASMA |
title_full_unstemmed |
AN LC- MS/MS METHOD FOR THE DETERMINATION OF OMEPRAZOLE ON PROTON PUMP INHIBITOR IN HUMAN PLASMA |
title_sort |
lc- ms/ms method for the determination of omeprazole on proton pump inhibitor in human plasma |
publisher |
Universitas Gadjah Mada |
series |
Indonesian Journal of Pharmacy |
issn |
2338-9427 2338-9486 |
publishDate |
2016-04-01 |
description |
A sensitive and selective liquid chromatographic method coupled with tandem mass spectroscopy (LC-MS/MS) was developed for the quantification of omeprazole in human plasma. Lansoprazole was used as internal standard with plasma samples, extracted using 10mM ammonium acetate. A centrifuged upper layer was then evaporated and reconstituted with Acetonitrile: mobile phase buffer 70:30%v/v. The reconstructed samples were injected into a C18 column purospher star 5µ. The mobile phase was composed of ACN: mobile phase buffer (5mm ammonium bicarbonate buffer) in the ratio of 70:30%v/v with flow rate 1.0mL/min. The mass spectrometer was operated using positive ion mode and turbo electro spray ionisation. Nitrogen was used as the nebulizer, curtain, collision and auxiliary gases. Using MS/MS with multiple reactions monitoring (MRM) mode, omeprazole was detected without severe interferences from plasma matrix. Detection of omeprazole in human plasma was accurate and precision. This method has been successfully applied to the study of omeprazole in human specimens |
topic |
Proton pump inhibitor omeprazole lansoprazole LC-MS/MS liquid liquid extraction |
url |
http://indonesianjpharm.farmasi.ugm.ac.id/index.php/3/article/view/1062 |
work_keys_str_mv |
AT tsudha anlcmsmsmethodforthedeterminationofomeprazoleonprotonpumpinhibitorinhumanplasma AT kalankumarreddy anlcmsmsmethodforthedeterminationofomeprazoleonprotonpumpinhibitorinhumanplasma AT pvhemalatha anlcmsmsmethodforthedeterminationofomeprazoleonprotonpumpinhibitorinhumanplasma AT vrravikumar anlcmsmsmethodforthedeterminationofomeprazoleonprotonpumpinhibitorinhumanplasma AT tsudha lcmsmsmethodforthedeterminationofomeprazoleonprotonpumpinhibitorinhumanplasma AT kalankumarreddy lcmsmsmethodforthedeterminationofomeprazoleonprotonpumpinhibitorinhumanplasma AT pvhemalatha lcmsmsmethodforthedeterminationofomeprazoleonprotonpumpinhibitorinhumanplasma AT vrravikumar lcmsmsmethodforthedeterminationofomeprazoleonprotonpumpinhibitorinhumanplasma |
_version_ |
1725230245078892544 |