Simulation of Working Processes in the Water-Tube Boiler Furnace with the Purpose of Reducing Emissions of Nitrogen Oxides

A significant number of domestic and industrial boilers are in operation in Ukraine. Nitrogen oxides are the most dangerous among all combustion products that pollute the atmosphere, therefore, one should take some measures for decreasing the formation of nitrogen oxides during combustion. The studi...

Full description

Bibliographic Details
Main Authors: Redko A.A., Davidenko A.V., Pavlovskiy S.V., Kulikova N.V., Pavlovskaya A.A., Redko I.A.
Format: Article
Language:English
Published: Academy of Sciences of Moldova 2017-04-01
Series:Problems of the Regional Energetics
Subjects:
a
Online Access:http://journal.ie.asm.md/assets/files/08_01_33_2017.pdf
id doaj-4e18d8d033b14e4d90ae8889a4dc33c9
record_format Article
spelling doaj-4e18d8d033b14e4d90ae8889a4dc33c92020-11-24T23:03:25ZengAcademy of Sciences of MoldovaProblems of the Regional Energetics1857-00702017-04-013315465Simulation of Working Processes in the Water-Tube Boiler Furnace with the Purpose of Reducing Emissions of Nitrogen Oxides Redko A.A.0Davidenko A.V.1Pavlovskiy S.V.2Kulikova N.V.3Pavlovskaya A.A.4Redko I.A.5Kharkiv National University of Construction and ArchitectureKharkiv National University of Construction and ArchitectureKharkiv National University of Construction and ArchitectureKharkiv National University of Construction and ArchitectureKharkiv National University of Construction and ArchitectureKharkiv National University of Urban Economy by O.M. Beketov Kharkiv, UkraineA significant number of domestic and industrial boilers are in operation in Ukraine. Nitrogen oxides are the most dangerous among all combustion products that pollute the atmosphere, therefore, one should take some measures for decreasing the formation of nitrogen oxides during combustion. The studies were carried out at the boilers of low power (100 kW) with a tubular radiator and an open end. The studies in the furnaces of industrial steam boilers having a tubular radiator with a closed end have not been done. The numerical study results of the gaseous fuel combustion processes in the furnace of a DE-10/14 steam water-tube boiler are presented. The fuel-air mixture is formed by premixing the 15% part of the air with a primary burner twist factor n=2.4 and a secondary burner twist factor n=1.6, and an air excess factor αв=10. As a result of the studies, the temperature and velocity distributions of gases in the combustion chamber, the density of heat flows on the screen tubular surfaces, and the concentrations of the combustion components were determined. Flue gas recirculation in the volume of 80-100% is provided, and the reversible movement of combustion products towards the combustion front provides a reduction in the concentration of nitrogen oxides up to 123-125 mg/m3 at the furnace outlet. Disadvantages are the following: the formation of stagnant zones near the end of the secondary radiator. The optimum diameter of the tubular radiator equals to two burners diameters and tubular radiator is located at a distance of one meter from the burner cutoff. http://journal.ie.asm.md/assets/files/08_01_33_2017.pdfwater-tube boilerafurnace
collection DOAJ
language English
format Article
sources DOAJ
author Redko A.A.
Davidenko A.V.
Pavlovskiy S.V.
Kulikova N.V.
Pavlovskaya A.A.
Redko I.A.
spellingShingle Redko A.A.
Davidenko A.V.
Pavlovskiy S.V.
Kulikova N.V.
Pavlovskaya A.A.
Redko I.A.
Simulation of Working Processes in the Water-Tube Boiler Furnace with the Purpose of Reducing Emissions of Nitrogen Oxides
Problems of the Regional Energetics
water-tube boiler
a
furnace
author_facet Redko A.A.
Davidenko A.V.
Pavlovskiy S.V.
Kulikova N.V.
Pavlovskaya A.A.
Redko I.A.
author_sort Redko A.A.
title Simulation of Working Processes in the Water-Tube Boiler Furnace with the Purpose of Reducing Emissions of Nitrogen Oxides
title_short Simulation of Working Processes in the Water-Tube Boiler Furnace with the Purpose of Reducing Emissions of Nitrogen Oxides
title_full Simulation of Working Processes in the Water-Tube Boiler Furnace with the Purpose of Reducing Emissions of Nitrogen Oxides
title_fullStr Simulation of Working Processes in the Water-Tube Boiler Furnace with the Purpose of Reducing Emissions of Nitrogen Oxides
title_full_unstemmed Simulation of Working Processes in the Water-Tube Boiler Furnace with the Purpose of Reducing Emissions of Nitrogen Oxides
title_sort simulation of working processes in the water-tube boiler furnace with the purpose of reducing emissions of nitrogen oxides
publisher Academy of Sciences of Moldova
series Problems of the Regional Energetics
issn 1857-0070
publishDate 2017-04-01
description A significant number of domestic and industrial boilers are in operation in Ukraine. Nitrogen oxides are the most dangerous among all combustion products that pollute the atmosphere, therefore, one should take some measures for decreasing the formation of nitrogen oxides during combustion. The studies were carried out at the boilers of low power (100 kW) with a tubular radiator and an open end. The studies in the furnaces of industrial steam boilers having a tubular radiator with a closed end have not been done. The numerical study results of the gaseous fuel combustion processes in the furnace of a DE-10/14 steam water-tube boiler are presented. The fuel-air mixture is formed by premixing the 15% part of the air with a primary burner twist factor n=2.4 and a secondary burner twist factor n=1.6, and an air excess factor αв=10. As a result of the studies, the temperature and velocity distributions of gases in the combustion chamber, the density of heat flows on the screen tubular surfaces, and the concentrations of the combustion components were determined. Flue gas recirculation in the volume of 80-100% is provided, and the reversible movement of combustion products towards the combustion front provides a reduction in the concentration of nitrogen oxides up to 123-125 mg/m3 at the furnace outlet. Disadvantages are the following: the formation of stagnant zones near the end of the secondary radiator. The optimum diameter of the tubular radiator equals to two burners diameters and tubular radiator is located at a distance of one meter from the burner cutoff.
topic water-tube boiler
a
furnace
url http://journal.ie.asm.md/assets/files/08_01_33_2017.pdf
work_keys_str_mv AT redkoaa simulationofworkingprocessesinthewatertubeboilerfurnacewiththepurposeofreducingemissionsofnitrogenoxides
AT davidenkoav simulationofworkingprocessesinthewatertubeboilerfurnacewiththepurposeofreducingemissionsofnitrogenoxides
AT pavlovskiysv simulationofworkingprocessesinthewatertubeboilerfurnacewiththepurposeofreducingemissionsofnitrogenoxides
AT kulikovanv simulationofworkingprocessesinthewatertubeboilerfurnacewiththepurposeofreducingemissionsofnitrogenoxides
AT pavlovskayaaa simulationofworkingprocessesinthewatertubeboilerfurnacewiththepurposeofreducingemissionsofnitrogenoxides
AT redkoia simulationofworkingprocessesinthewatertubeboilerfurnacewiththepurposeofreducingemissionsofnitrogenoxides
_version_ 1725633881730711552