Duty-Cycle and Duty-off Factor Measurements Based on Universal Sensors and Transducers Interface (USTI-MOB) IC
An experimental investigation of metrological characteristics of designed Universal Sensors and Transducers Interface (USTI-MOB) integrated circuit working in duty-cycle and duty-off factor measuring modes is described in the article. The USTI-MOB is based on the novel patented methods for duty-cycl...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
IFSA Publishing, S.L.
2015-09-01
|
Series: | Sensors & Transducers |
Subjects: | |
Online Access: | http://www.sensorsportal.com/HTML/DIGEST/september_2015/Vol_192/P_2700.pdf |
id |
doaj-4facc4bb07554ee6a987dd42887614d6 |
---|---|
record_format |
Article |
spelling |
doaj-4facc4bb07554ee6a987dd42887614d62020-11-25T00:21:31ZengIFSA Publishing, S.L.Sensors & Transducers2306-85151726-54792015-09-01192918Duty-Cycle and Duty-off Factor Measurements Based on Universal Sensors and Transducers Interface (USTI-MOB) IC Sergey Y. Yurish0Javier Caňete1Excelera, S. L., Parc UPC-PMT, Edificio RDIT-K2M, c/ Esteve Terradas, 1, 08860, Castelldefels, Barcelona, SpainExcelera, S. L., Parc UPC-PMT, Edificio RDIT-K2M, c/ Esteve Terradas, 1, 08860, Castelldefels, Barcelona, SpainAn experimental investigation of metrological characteristics of designed Universal Sensors and Transducers Interface (USTI-MOB) integrated circuit working in duty-cycle and duty-off factor measuring modes is described in the article. The USTI-MOB is based on the novel patented methods for duty-cycle – to – digital conversion. Experiments have confirmed the high metrological performance at low power consumption (0.35 mA current consumption at Vcc = 1.8 V). So, the relative error of duty-cycle – to – code conversion is changed from ±0.08 to ±1.00 % in all specified measuring range of USTI-MOB. Metrological characteristics and functionality make the USTI-MOB very suitable for various sensor systems designs, based on duty-cycle output sensors. In this case the significant time-to- marked reduction and design simplification can be achieved. http://www.sensorsportal.com/HTML/DIGEST/september_2015/Vol_192/P_2700.pdfUniversal Sensors and Transducers InterfaceUSTI-MOBduty-cycle measurementduty-off factor |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Sergey Y. Yurish Javier Caňete |
spellingShingle |
Sergey Y. Yurish Javier Caňete Duty-Cycle and Duty-off Factor Measurements Based on Universal Sensors and Transducers Interface (USTI-MOB) IC Sensors & Transducers Universal Sensors and Transducers Interface USTI-MOB duty-cycle measurement duty-off factor |
author_facet |
Sergey Y. Yurish Javier Caňete |
author_sort |
Sergey Y. Yurish |
title |
Duty-Cycle and Duty-off Factor Measurements Based on Universal Sensors and Transducers Interface (USTI-MOB) IC |
title_short |
Duty-Cycle and Duty-off Factor Measurements Based on Universal Sensors and Transducers Interface (USTI-MOB) IC |
title_full |
Duty-Cycle and Duty-off Factor Measurements Based on Universal Sensors and Transducers Interface (USTI-MOB) IC |
title_fullStr |
Duty-Cycle and Duty-off Factor Measurements Based on Universal Sensors and Transducers Interface (USTI-MOB) IC |
title_full_unstemmed |
Duty-Cycle and Duty-off Factor Measurements Based on Universal Sensors and Transducers Interface (USTI-MOB) IC |
title_sort |
duty-cycle and duty-off factor measurements based on universal sensors and transducers interface (usti-mob) ic |
publisher |
IFSA Publishing, S.L. |
series |
Sensors & Transducers |
issn |
2306-8515 1726-5479 |
publishDate |
2015-09-01 |
description |
An experimental investigation of metrological characteristics of designed Universal Sensors and Transducers Interface (USTI-MOB) integrated circuit working in duty-cycle and duty-off factor measuring modes is described in the article. The USTI-MOB is based on the novel patented methods for duty-cycle – to – digital conversion. Experiments have confirmed the high metrological performance at low power consumption (0.35 mA current consumption at Vcc = 1.8 V). So, the relative error of duty-cycle – to – code conversion is changed from ±0.08 to ±1.00 % in all specified measuring range of USTI-MOB. Metrological characteristics and functionality make the USTI-MOB very suitable for various sensor systems designs, based on duty-cycle output sensors. In this case the significant time-to- marked reduction and design simplification can be achieved.
|
topic |
Universal Sensors and Transducers Interface USTI-MOB duty-cycle measurement duty-off factor |
url |
http://www.sensorsportal.com/HTML/DIGEST/september_2015/Vol_192/P_2700.pdf |
work_keys_str_mv |
AT sergeyyyurish dutycycleanddutyofffactormeasurementsbasedonuniversalsensorsandtransducersinterfaceustimobic AT javiercanete dutycycleanddutyofffactormeasurementsbasedonuniversalsensorsandtransducersinterfaceustimobic |
_version_ |
1725362328782766080 |