Home monitoring report from a single lead Lumax DX implantable cardioverter defibrillator: New observations in a new system
A 56-year-old man underwent a single lead Lumax 640 DX implantable cardioverter defibrillator implantation for primary prevention of sudden cardiac death. A DX system consists of a single lead, which provides atrial as well as ventricular electrograms, and enhances atrial arrhythmia detection. Three...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2016-06-01
|
Series: | Journal of Arrhythmia |
Subjects: | |
Online Access: | http://www.sciencedirect.com/science/article/pii/S1880427616000028 |
id |
doaj-4feb0f6a6c2949b38a298ccb2ac89a1f |
---|---|
record_format |
Article |
spelling |
doaj-4feb0f6a6c2949b38a298ccb2ac89a1f2020-11-25T00:31:53ZengWileyJournal of Arrhythmia1880-42762016-06-0132321821910.1016/j.joa.2015.12.004Home monitoring report from a single lead Lumax DX implantable cardioverter defibrillator: New observations in a new systemYuval Konstantino0Alex Kleiman1Guy Amit2Department of Cardiology, Soroka University Medical Center and Faculty of Health Sciences, Ben-Gurion University of the Negev, P.O. Box 151, Beer Sheva, IsraelBiotronik, P.O. Box 1293, Kochav Yair 44864, IsraelDepartment of Cardiology, Soroka University Medical Center and Faculty of Health Sciences, Ben-Gurion University of the Negev, P.O. Box 151, Beer Sheva, IsraelA 56-year-old man underwent a single lead Lumax 640 DX implantable cardioverter defibrillator implantation for primary prevention of sudden cardiac death. A DX system consists of a single lead, which provides atrial as well as ventricular electrograms, and enhances atrial arrhythmia detection. Three months after the implantation, high-frequency episodes were detected on the far field and the atrial channels, but not on the bipolar right ventricular channel; these were classified as atrial tachycardia. In the present report, we discussed the unusual pattern of the artifacts that was related to an electromagnetic interference detected by the novel DX system.http://www.sciencedirect.com/science/article/pii/S1880427616000028Lumax DX ICDElectromagnetic interference (EMI) |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Yuval Konstantino Alex Kleiman Guy Amit |
spellingShingle |
Yuval Konstantino Alex Kleiman Guy Amit Home monitoring report from a single lead Lumax DX implantable cardioverter defibrillator: New observations in a new system Journal of Arrhythmia Lumax DX ICD Electromagnetic interference (EMI) |
author_facet |
Yuval Konstantino Alex Kleiman Guy Amit |
author_sort |
Yuval Konstantino |
title |
Home monitoring report from a single lead Lumax DX implantable cardioverter defibrillator: New observations in a new system |
title_short |
Home monitoring report from a single lead Lumax DX implantable cardioverter defibrillator: New observations in a new system |
title_full |
Home monitoring report from a single lead Lumax DX implantable cardioverter defibrillator: New observations in a new system |
title_fullStr |
Home monitoring report from a single lead Lumax DX implantable cardioverter defibrillator: New observations in a new system |
title_full_unstemmed |
Home monitoring report from a single lead Lumax DX implantable cardioverter defibrillator: New observations in a new system |
title_sort |
home monitoring report from a single lead lumax dx implantable cardioverter defibrillator: new observations in a new system |
publisher |
Wiley |
series |
Journal of Arrhythmia |
issn |
1880-4276 |
publishDate |
2016-06-01 |
description |
A 56-year-old man underwent a single lead Lumax 640 DX implantable cardioverter defibrillator implantation for primary prevention of sudden cardiac death. A DX system consists of a single lead, which provides atrial as well as ventricular electrograms, and enhances atrial arrhythmia detection. Three months after the implantation, high-frequency episodes were detected on the far field and the atrial channels, but not on the bipolar right ventricular channel; these were classified as atrial tachycardia. In the present report, we discussed the unusual pattern of the artifacts that was related to an electromagnetic interference detected by the novel DX system. |
topic |
Lumax DX ICD Electromagnetic interference (EMI) |
url |
http://www.sciencedirect.com/science/article/pii/S1880427616000028 |
work_keys_str_mv |
AT yuvalkonstantino homemonitoringreportfromasingleleadlumaxdximplantablecardioverterdefibrillatornewobservationsinanewsystem AT alexkleiman homemonitoringreportfromasingleleadlumaxdximplantablecardioverterdefibrillatornewobservationsinanewsystem AT guyamit homemonitoringreportfromasingleleadlumaxdximplantablecardioverterdefibrillatornewobservationsinanewsystem |
_version_ |
1725321831713341440 |