Home monitoring report from a single lead Lumax DX implantable cardioverter defibrillator: New observations in a new system

A 56-year-old man underwent a single lead Lumax 640 DX implantable cardioverter defibrillator implantation for primary prevention of sudden cardiac death. A DX system consists of a single lead, which provides atrial as well as ventricular electrograms, and enhances atrial arrhythmia detection. Three...

Full description

Bibliographic Details
Main Authors: Yuval Konstantino, Alex Kleiman, Guy Amit
Format: Article
Language:English
Published: Wiley 2016-06-01
Series:Journal of Arrhythmia
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S1880427616000028
id doaj-4feb0f6a6c2949b38a298ccb2ac89a1f
record_format Article
spelling doaj-4feb0f6a6c2949b38a298ccb2ac89a1f2020-11-25T00:31:53ZengWileyJournal of Arrhythmia1880-42762016-06-0132321821910.1016/j.joa.2015.12.004Home monitoring report from a single lead Lumax DX implantable cardioverter defibrillator: New observations in a new systemYuval Konstantino0Alex Kleiman1Guy Amit2Department of Cardiology, Soroka University Medical Center and Faculty of Health Sciences, Ben-Gurion University of the Negev, P.O. Box 151, Beer Sheva, IsraelBiotronik, P.O. Box 1293, Kochav Yair 44864, IsraelDepartment of Cardiology, Soroka University Medical Center and Faculty of Health Sciences, Ben-Gurion University of the Negev, P.O. Box 151, Beer Sheva, IsraelA 56-year-old man underwent a single lead Lumax 640 DX implantable cardioverter defibrillator implantation for primary prevention of sudden cardiac death. A DX system consists of a single lead, which provides atrial as well as ventricular electrograms, and enhances atrial arrhythmia detection. Three months after the implantation, high-frequency episodes were detected on the far field and the atrial channels, but not on the bipolar right ventricular channel; these were classified as atrial tachycardia. In the present report, we discussed the unusual pattern of the artifacts that was related to an electromagnetic interference detected by the novel DX system.http://www.sciencedirect.com/science/article/pii/S1880427616000028Lumax DX ICDElectromagnetic interference (EMI)
collection DOAJ
language English
format Article
sources DOAJ
author Yuval Konstantino
Alex Kleiman
Guy Amit
spellingShingle Yuval Konstantino
Alex Kleiman
Guy Amit
Home monitoring report from a single lead Lumax DX implantable cardioverter defibrillator: New observations in a new system
Journal of Arrhythmia
Lumax DX ICD
Electromagnetic interference (EMI)
author_facet Yuval Konstantino
Alex Kleiman
Guy Amit
author_sort Yuval Konstantino
title Home monitoring report from a single lead Lumax DX implantable cardioverter defibrillator: New observations in a new system
title_short Home monitoring report from a single lead Lumax DX implantable cardioverter defibrillator: New observations in a new system
title_full Home monitoring report from a single lead Lumax DX implantable cardioverter defibrillator: New observations in a new system
title_fullStr Home monitoring report from a single lead Lumax DX implantable cardioverter defibrillator: New observations in a new system
title_full_unstemmed Home monitoring report from a single lead Lumax DX implantable cardioverter defibrillator: New observations in a new system
title_sort home monitoring report from a single lead lumax dx implantable cardioverter defibrillator: new observations in a new system
publisher Wiley
series Journal of Arrhythmia
issn 1880-4276
publishDate 2016-06-01
description A 56-year-old man underwent a single lead Lumax 640 DX implantable cardioverter defibrillator implantation for primary prevention of sudden cardiac death. A DX system consists of a single lead, which provides atrial as well as ventricular electrograms, and enhances atrial arrhythmia detection. Three months after the implantation, high-frequency episodes were detected on the far field and the atrial channels, but not on the bipolar right ventricular channel; these were classified as atrial tachycardia. In the present report, we discussed the unusual pattern of the artifacts that was related to an electromagnetic interference detected by the novel DX system.
topic Lumax DX ICD
Electromagnetic interference (EMI)
url http://www.sciencedirect.com/science/article/pii/S1880427616000028
work_keys_str_mv AT yuvalkonstantino homemonitoringreportfromasingleleadlumaxdximplantablecardioverterdefibrillatornewobservationsinanewsystem
AT alexkleiman homemonitoringreportfromasingleleadlumaxdximplantablecardioverterdefibrillatornewobservationsinanewsystem
AT guyamit homemonitoringreportfromasingleleadlumaxdximplantablecardioverterdefibrillatornewobservationsinanewsystem
_version_ 1725321831713341440