Study on a standard for grounding systems realization

Grounding systems of objects inside power facilities are very often realized as structures consisting of protective electrodes’ system placed in the object foundation, and neutral electrodes’ system placed at a specified distance from the object. Official standards and publications recommen...

Full description

Bibliographic Details
Main Authors: Vučković Dragan D., Cvetković Nenad N., Stojanović Miodrag S.
Format: Article
Language:English
Published: Faculty of Technical Sciences in Cacak 2012-01-01
Series:Serbian Journal of Electrical Engineering
Subjects:
Online Access:http://www.doiserbia.nb.rs/img/doi/1451-4869/2012/1451-48691203393V.pdf
id doaj-50211aad97f34115a38bea0e7d10080d
record_format Article
spelling doaj-50211aad97f34115a38bea0e7d10080d2020-11-25T00:10:04ZengFaculty of Technical Sciences in CacakSerbian Journal of Electrical Engineering1451-48692217-71832012-01-019339340110.2298/SJEE1203393V1451-48691203393VStudy on a standard for grounding systems realizationVučković Dragan D.0Cvetković Nenad N.1Stojanović Miodrag S.2Faculty of Electronic Engineering, NišFaculty of Electronic Engineering, NišFaculty of Electronic Engineering, NišGrounding systems of objects inside power facilities are very often realized as structures consisting of protective electrodes’ system placed in the object foundation, and neutral electrodes’ system placed at a specified distance from the object. Official standards and publications recommend a minimal value for the distance between the protective and the neutral part of grounding structures, so that the influence of one on another can be neglected. We analyze several practical implementations of grounding structures and demonstrate that the minimal distance is actually much smaller than that recommended by the standards.http://www.doiserbia.nb.rs/img/doi/1451-4869/2012/1451-48691203393V.pdfgrounding electrodegrounding systemmethod of momentspower Stationresistance
collection DOAJ
language English
format Article
sources DOAJ
author Vučković Dragan D.
Cvetković Nenad N.
Stojanović Miodrag S.
spellingShingle Vučković Dragan D.
Cvetković Nenad N.
Stojanović Miodrag S.
Study on a standard for grounding systems realization
Serbian Journal of Electrical Engineering
grounding electrode
grounding system
method of moments
power Station
resistance
author_facet Vučković Dragan D.
Cvetković Nenad N.
Stojanović Miodrag S.
author_sort Vučković Dragan D.
title Study on a standard for grounding systems realization
title_short Study on a standard for grounding systems realization
title_full Study on a standard for grounding systems realization
title_fullStr Study on a standard for grounding systems realization
title_full_unstemmed Study on a standard for grounding systems realization
title_sort study on a standard for grounding systems realization
publisher Faculty of Technical Sciences in Cacak
series Serbian Journal of Electrical Engineering
issn 1451-4869
2217-7183
publishDate 2012-01-01
description Grounding systems of objects inside power facilities are very often realized as structures consisting of protective electrodes’ system placed in the object foundation, and neutral electrodes’ system placed at a specified distance from the object. Official standards and publications recommend a minimal value for the distance between the protective and the neutral part of grounding structures, so that the influence of one on another can be neglected. We analyze several practical implementations of grounding structures and demonstrate that the minimal distance is actually much smaller than that recommended by the standards.
topic grounding electrode
grounding system
method of moments
power Station
resistance
url http://www.doiserbia.nb.rs/img/doi/1451-4869/2012/1451-48691203393V.pdf
work_keys_str_mv AT vuckovicdragand studyonastandardforgroundingsystemsrealization
AT cvetkovicnenadn studyonastandardforgroundingsystemsrealization
AT stojanovicmiodrags studyonastandardforgroundingsystemsrealization
_version_ 1725409543654998016