Shear Cap Size Selection Method Based on Parametric Analysis of ACI-318 Code and Eurocode 2 Standard

The scope of the paper is to propose a method for determining the size of shear caps in a slab–column-connections-reinforced concrete structure. Usually, shear heads are used to enhance slab–column connection, especially when the transverse reinforcement does not give the required punching shear loa...

Full description

Bibliographic Details
Main Authors: Maciej Grabski, Andrzej Ambroziak
Format: Article
Language:English
Published: MDPI AG 2020-11-01
Series:Materials
Subjects:
Online Access:https://www.mdpi.com/1996-1944/13/21/4938
id doaj-50c8e38c4c5a4afcb2c5c8aaaf8d6be8
record_format Article
spelling doaj-50c8e38c4c5a4afcb2c5c8aaaf8d6be82020-11-25T04:08:08ZengMDPI AGMaterials1996-19442020-11-01134938493810.3390/ma13214938Shear Cap Size Selection Method Based on Parametric Analysis of ACI-318 Code and Eurocode 2 StandardMaciej Grabski0Andrzej Ambroziak1Faculty of Civil and Environmental Engineering, Gdansk University of Technology, 11/12 Gabriela Narutowicza Street, 80-233 Gdańsk, PolandFaculty of Civil and Environmental Engineering, Gdansk University of Technology, 11/12 Gabriela Narutowicza Street, 80-233 Gdańsk, PolandThe scope of the paper is to propose a method for determining the size of shear caps in a slab–column-connections-reinforced concrete structure. Usually, shear heads are used to enhance slab–column connection, especially when the transverse reinforcement does not give the required punching shear load capacity. The dimensions of the shear head should provide the punching shear resistance of the connection inside and outside the enhanced region. The process of selecting the size of the shear head is iterative. The parametric analysis of the ACI 318 code and EC2 standard has the objective of indicating which control perimeter (inside or outside the shear head) has a decisive impact on the punching shear capacity of the connection. Based on the analysis, the authors propose methods for selecting the dimensions of the shear head with practical application examples. The paper is intended to provide scientists, civil engineers, and designers with guidelines to design the process of the slab–column connections with the shear caps.https://www.mdpi.com/1996-1944/13/21/4938reinforced concreteslab-column connectionspunching shearshear capshear head.
collection DOAJ
language English
format Article
sources DOAJ
author Maciej Grabski
Andrzej Ambroziak
spellingShingle Maciej Grabski
Andrzej Ambroziak
Shear Cap Size Selection Method Based on Parametric Analysis of ACI-318 Code and Eurocode 2 Standard
Materials
reinforced concrete
slab-column connections
punching shear
shear cap
shear head.
author_facet Maciej Grabski
Andrzej Ambroziak
author_sort Maciej Grabski
title Shear Cap Size Selection Method Based on Parametric Analysis of ACI-318 Code and Eurocode 2 Standard
title_short Shear Cap Size Selection Method Based on Parametric Analysis of ACI-318 Code and Eurocode 2 Standard
title_full Shear Cap Size Selection Method Based on Parametric Analysis of ACI-318 Code and Eurocode 2 Standard
title_fullStr Shear Cap Size Selection Method Based on Parametric Analysis of ACI-318 Code and Eurocode 2 Standard
title_full_unstemmed Shear Cap Size Selection Method Based on Parametric Analysis of ACI-318 Code and Eurocode 2 Standard
title_sort shear cap size selection method based on parametric analysis of aci-318 code and eurocode 2 standard
publisher MDPI AG
series Materials
issn 1996-1944
publishDate 2020-11-01
description The scope of the paper is to propose a method for determining the size of shear caps in a slab–column-connections-reinforced concrete structure. Usually, shear heads are used to enhance slab–column connection, especially when the transverse reinforcement does not give the required punching shear load capacity. The dimensions of the shear head should provide the punching shear resistance of the connection inside and outside the enhanced region. The process of selecting the size of the shear head is iterative. The parametric analysis of the ACI 318 code and EC2 standard has the objective of indicating which control perimeter (inside or outside the shear head) has a decisive impact on the punching shear capacity of the connection. Based on the analysis, the authors propose methods for selecting the dimensions of the shear head with practical application examples. The paper is intended to provide scientists, civil engineers, and designers with guidelines to design the process of the slab–column connections with the shear caps.
topic reinforced concrete
slab-column connections
punching shear
shear cap
shear head.
url https://www.mdpi.com/1996-1944/13/21/4938
work_keys_str_mv AT maciejgrabski shearcapsizeselectionmethodbasedonparametricanalysisofaci318codeandeurocode2standard
AT andrzejambroziak shearcapsizeselectionmethodbasedonparametricanalysisofaci318codeandeurocode2standard
_version_ 1724426650468220928