One stage release of circumferential constriction band in upper limb with multiple Z-plasty technique: a case report

<p><strong>INTRODUCTION</strong>: </p><p>Congenital constriction band is an uncommon congenital abnormality with multiple disfiguring and disabling manifestations. The widely known management for the correction of congenital constriction band especially in circumferenti...

Full description

Bibliographic Details
Main Authors: I Gusti Putu Hendra Sanjaya, Agus Roy Rusli Hariantana Hamid, Gede Wara Samsarga
Format: Article
Language:English
Published: Universitas Udayana 2019-07-01
Series:Indonesia Journal of Biomedical Science
Subjects:
Online Access:https://ijbs-udayana.org/index.php/ijbs/article/view/190
id doaj-55c4dd7cea5942ad84fde4bce490d9c1
record_format Article
spelling doaj-55c4dd7cea5942ad84fde4bce490d9c12020-11-25T03:38:22ZengUniversitas UdayanaIndonesia Journal of Biomedical Science2302-29062019-07-0113210.15562/ijbs.v%vi%i.190157One stage release of circumferential constriction band in upper limb with multiple Z-plasty technique: a case reportI Gusti Putu Hendra Sanjaya0Agus Roy Rusli Hariantana Hamid1Gede Wara Samsarga2Plastic Reconstructive and Aesthetic Surgeon, Faculty of Medicine, Udayana University/ Sanglah General Hospital, Bali, IndonesiaPlastic Reconstructive and Aesthetic Surgeon, Faculty of Medicine, Udayana University/ Sanglah General Hospital, Bali, IndonesiaPlastic Reconstructive and Aesthetic Surgery Resident, Faculty of Medicine, Udayana University, Sanglah General Hospital, Bali, Indonesia<p><strong>INTRODUCTION</strong>: </p><p>Congenital constriction band is an uncommon congenital abnormality with multiple disfiguring and disabling manifestations. The widely known management for the correction of congenital constriction band especially in circumferential constriction band is done in a multistage release of constriction band to eluding vascular and lymphatic embarrassment. The purpose of this case report was to present the outcome of one-stage release in terms of safety and aesthetic appearance.</p><p> </p><p><strong>CASE DESCRIPTION</strong>:</p><p>Women 28 year old came to outpatient plastic surgery clinic presented with circumferential constriction with no functional disability in her right arm since birth. Excision based on design of multiple Z-Plasty is started 2 cm proximal and distal from constricted band. The multiple Z- Plasty flaps are transposed around each other, changing the direction of the constriction band.  Postoperatively, the extremity circulation was normal, and no edema was observed. The range of motion is within normal limits and aesthetically acceptable for the patient.</p><p> </p><p><strong>DISCUSSION</strong>: Patterson classified constriction ring syndrome into four types, and type II is the most common. In type II Paterson , there are normal full-layer skin structures and no important nerve or blood vessel was affected so an incision completely encircling an extremity would not interfere with distal circulation and provided strong evidence that one-stage resection of constriction band could be performed. Using multiple Z-Plasty for constriction band release leads to improvement of functional and cosmetic appearance of the defect.</p><p> </p><pre><strong>CONCLUSION:</strong> </pre><pre>A one-stage release of circumferential constriction band in the upper limb using multiple Z-Plasty is considered as a safe treatment with an aesthetically acceptable result for the patient</pre>https://ijbs-udayana.org/index.php/ijbs/article/view/190constriction band, one-stage release, multiple z-plasty
collection DOAJ
language English
format Article
sources DOAJ
author I Gusti Putu Hendra Sanjaya
Agus Roy Rusli Hariantana Hamid
Gede Wara Samsarga
spellingShingle I Gusti Putu Hendra Sanjaya
Agus Roy Rusli Hariantana Hamid
Gede Wara Samsarga
One stage release of circumferential constriction band in upper limb with multiple Z-plasty technique: a case report
Indonesia Journal of Biomedical Science
constriction band, one-stage release, multiple z-plasty
author_facet I Gusti Putu Hendra Sanjaya
Agus Roy Rusli Hariantana Hamid
Gede Wara Samsarga
author_sort I Gusti Putu Hendra Sanjaya
title One stage release of circumferential constriction band in upper limb with multiple Z-plasty technique: a case report
title_short One stage release of circumferential constriction band in upper limb with multiple Z-plasty technique: a case report
title_full One stage release of circumferential constriction band in upper limb with multiple Z-plasty technique: a case report
title_fullStr One stage release of circumferential constriction band in upper limb with multiple Z-plasty technique: a case report
title_full_unstemmed One stage release of circumferential constriction band in upper limb with multiple Z-plasty technique: a case report
title_sort one stage release of circumferential constriction band in upper limb with multiple z-plasty technique: a case report
publisher Universitas Udayana
series Indonesia Journal of Biomedical Science
issn 2302-2906
publishDate 2019-07-01
description <p><strong>INTRODUCTION</strong>: </p><p>Congenital constriction band is an uncommon congenital abnormality with multiple disfiguring and disabling manifestations. The widely known management for the correction of congenital constriction band especially in circumferential constriction band is done in a multistage release of constriction band to eluding vascular and lymphatic embarrassment. The purpose of this case report was to present the outcome of one-stage release in terms of safety and aesthetic appearance.</p><p> </p><p><strong>CASE DESCRIPTION</strong>:</p><p>Women 28 year old came to outpatient plastic surgery clinic presented with circumferential constriction with no functional disability in her right arm since birth. Excision based on design of multiple Z-Plasty is started 2 cm proximal and distal from constricted band. The multiple Z- Plasty flaps are transposed around each other, changing the direction of the constriction band.  Postoperatively, the extremity circulation was normal, and no edema was observed. The range of motion is within normal limits and aesthetically acceptable for the patient.</p><p> </p><p><strong>DISCUSSION</strong>: Patterson classified constriction ring syndrome into four types, and type II is the most common. In type II Paterson , there are normal full-layer skin structures and no important nerve or blood vessel was affected so an incision completely encircling an extremity would not interfere with distal circulation and provided strong evidence that one-stage resection of constriction band could be performed. Using multiple Z-Plasty for constriction band release leads to improvement of functional and cosmetic appearance of the defect.</p><p> </p><pre><strong>CONCLUSION:</strong> </pre><pre>A one-stage release of circumferential constriction band in the upper limb using multiple Z-Plasty is considered as a safe treatment with an aesthetically acceptable result for the patient</pre>
topic constriction band, one-stage release, multiple z-plasty
url https://ijbs-udayana.org/index.php/ijbs/article/view/190
work_keys_str_mv AT igustiputuhendrasanjaya onestagereleaseofcircumferentialconstrictionbandinupperlimbwithmultiplezplastytechniqueacasereport
AT agusroyruslihariantanahamid onestagereleaseofcircumferentialconstrictionbandinupperlimbwithmultiplezplastytechniqueacasereport
AT gedewarasamsarga onestagereleaseofcircumferentialconstrictionbandinupperlimbwithmultiplezplastytechniqueacasereport
_version_ 1724542502164234240