An Analysis of Energy Consumption in the Campus Building’s Operation (Case Study: The Building of Faculty of Engineering and Department of Civil and Environmental Engineering, Universitas Gadjah Mada)

Energy Consumption Intensity (IKE) is an indicator that is used to determine the amount of energy used per area by an air-conditioned building within a month or a year as a reference to determine how much energy conservation can be done in the building. To determine the energy consumption of buildin...

Full description

Bibliographic Details
Main Authors: Syarifudin Syarifudin, Ashar Saputra, Suprapto Siswosukarto
Format: Article
Language:English
Published: Universitas Gadjah Mada 2018-01-01
Series:Journal of the Civil Engineering Forum
Subjects:
Online Access:https://jurnal.ugm.ac.id/jcef/article/view/27642
id doaj-55f49fcc554b4e9988799f5de424c272
record_format Article
spelling doaj-55f49fcc554b4e9988799f5de424c2722020-11-24T20:44:17ZengUniversitas Gadjah MadaJournal of the Civil Engineering Forum2581-10372549-59252018-01-0141576810.22146/jcef.2764219755An Analysis of Energy Consumption in the Campus Building’s Operation (Case Study: The Building of Faculty of Engineering and Department of Civil and Environmental Engineering, Universitas Gadjah Mada)Syarifudin Syarifudin0Ashar Saputra1Suprapto Siswosukarto2Politeknik Negeri Nunukan, NunukanDepartment of Civil and Environmental Engineering, Universitas Gadjah Mada, YogyakartaDepartment of Civil and Environmental Engineering, Universitas Gadjah Mada, YogyakartaEnergy Consumption Intensity (IKE) is an indicator that is used to determine the amount of energy used per area by an air-conditioned building within a month or a year as a reference to determine how much energy conservation can be done in the building. To determine the energy consumption of buildings and to determine the savings opportunities, there should be an effort to review the energy consumption through energy audits. In this research, energy consumption analysis was conducted at the Main Office building of the Faculty of Engineering (KPFT) and Department of Civil Engineering and Environmental (CEED) of UniversitasGadjah Mada Yogyakarta. The analysis was conducted on the main variables of energy efficiency, namely: measurement of temperature and relative humidity, calculation of Overall Thermal Transfer Value (OTTV) and Roof Thermal Transfer Value (RTTV), calculation of Energy Consumption Intensity (IKE) in air-conditioned and non-air-conditioned rooms as well as an analysis of opportunities to increase the efficiency of energy consumption in the buildings.The results showed that the temperature and the relative humidity of the KPFT building = 28.4℃ and 62%, while CEED Building = 28.4℃ dan 65%. Calculation of average OTTV of the KPFT building = 17.61 W/m2 and CEED building = 43.05 W/m2. Average IKE of the KPFT building in 2015 was 3.25 kWh/m2/month and in 2016 was 3.45 kWh/m2/month, while the average IKE of CEED building in 2015 was 1.5 kWh/m2/month and in 2016 was 0.79 kWh/m2/month. Based on the calculation of IKE in both buildings, they are still considered in the category of efficient. However, based on the measurement of temperature and relative humidity, it shows that in both buildings air conditioning is still necessary to achieve the level of thermal comfort, therefore an increase of efficiency in the load is needed to avoid wastage.https://jurnal.ugm.ac.id/jcef/article/view/27642Energy Audit, IKE, Conventional Building, Thermal Comfort
collection DOAJ
language English
format Article
sources DOAJ
author Syarifudin Syarifudin
Ashar Saputra
Suprapto Siswosukarto
spellingShingle Syarifudin Syarifudin
Ashar Saputra
Suprapto Siswosukarto
An Analysis of Energy Consumption in the Campus Building’s Operation (Case Study: The Building of Faculty of Engineering and Department of Civil and Environmental Engineering, Universitas Gadjah Mada)
Journal of the Civil Engineering Forum
Energy Audit, IKE, Conventional Building, Thermal Comfort
author_facet Syarifudin Syarifudin
Ashar Saputra
Suprapto Siswosukarto
author_sort Syarifudin Syarifudin
title An Analysis of Energy Consumption in the Campus Building’s Operation (Case Study: The Building of Faculty of Engineering and Department of Civil and Environmental Engineering, Universitas Gadjah Mada)
title_short An Analysis of Energy Consumption in the Campus Building’s Operation (Case Study: The Building of Faculty of Engineering and Department of Civil and Environmental Engineering, Universitas Gadjah Mada)
title_full An Analysis of Energy Consumption in the Campus Building’s Operation (Case Study: The Building of Faculty of Engineering and Department of Civil and Environmental Engineering, Universitas Gadjah Mada)
title_fullStr An Analysis of Energy Consumption in the Campus Building’s Operation (Case Study: The Building of Faculty of Engineering and Department of Civil and Environmental Engineering, Universitas Gadjah Mada)
title_full_unstemmed An Analysis of Energy Consumption in the Campus Building’s Operation (Case Study: The Building of Faculty of Engineering and Department of Civil and Environmental Engineering, Universitas Gadjah Mada)
title_sort analysis of energy consumption in the campus building’s operation (case study: the building of faculty of engineering and department of civil and environmental engineering, universitas gadjah mada)
publisher Universitas Gadjah Mada
series Journal of the Civil Engineering Forum
issn 2581-1037
2549-5925
publishDate 2018-01-01
description Energy Consumption Intensity (IKE) is an indicator that is used to determine the amount of energy used per area by an air-conditioned building within a month or a year as a reference to determine how much energy conservation can be done in the building. To determine the energy consumption of buildings and to determine the savings opportunities, there should be an effort to review the energy consumption through energy audits. In this research, energy consumption analysis was conducted at the Main Office building of the Faculty of Engineering (KPFT) and Department of Civil Engineering and Environmental (CEED) of UniversitasGadjah Mada Yogyakarta. The analysis was conducted on the main variables of energy efficiency, namely: measurement of temperature and relative humidity, calculation of Overall Thermal Transfer Value (OTTV) and Roof Thermal Transfer Value (RTTV), calculation of Energy Consumption Intensity (IKE) in air-conditioned and non-air-conditioned rooms as well as an analysis of opportunities to increase the efficiency of energy consumption in the buildings.The results showed that the temperature and the relative humidity of the KPFT building = 28.4℃ and 62%, while CEED Building = 28.4℃ dan 65%. Calculation of average OTTV of the KPFT building = 17.61 W/m2 and CEED building = 43.05 W/m2. Average IKE of the KPFT building in 2015 was 3.25 kWh/m2/month and in 2016 was 3.45 kWh/m2/month, while the average IKE of CEED building in 2015 was 1.5 kWh/m2/month and in 2016 was 0.79 kWh/m2/month. Based on the calculation of IKE in both buildings, they are still considered in the category of efficient. However, based on the measurement of temperature and relative humidity, it shows that in both buildings air conditioning is still necessary to achieve the level of thermal comfort, therefore an increase of efficiency in the load is needed to avoid wastage.
topic Energy Audit, IKE, Conventional Building, Thermal Comfort
url https://jurnal.ugm.ac.id/jcef/article/view/27642
work_keys_str_mv AT syarifudinsyarifudin ananalysisofenergyconsumptioninthecampusbuildingsoperationcasestudythebuildingoffacultyofengineeringanddepartmentofcivilandenvironmentalengineeringuniversitasgadjahmada
AT asharsaputra ananalysisofenergyconsumptioninthecampusbuildingsoperationcasestudythebuildingoffacultyofengineeringanddepartmentofcivilandenvironmentalengineeringuniversitasgadjahmada
AT supraptosiswosukarto ananalysisofenergyconsumptioninthecampusbuildingsoperationcasestudythebuildingoffacultyofengineeringanddepartmentofcivilandenvironmentalengineeringuniversitasgadjahmada
AT syarifudinsyarifudin analysisofenergyconsumptioninthecampusbuildingsoperationcasestudythebuildingoffacultyofengineeringanddepartmentofcivilandenvironmentalengineeringuniversitasgadjahmada
AT asharsaputra analysisofenergyconsumptioninthecampusbuildingsoperationcasestudythebuildingoffacultyofengineeringanddepartmentofcivilandenvironmentalengineeringuniversitasgadjahmada
AT supraptosiswosukarto analysisofenergyconsumptioninthecampusbuildingsoperationcasestudythebuildingoffacultyofengineeringanddepartmentofcivilandenvironmentalengineeringuniversitasgadjahmada
_version_ 1716817880395284480