Avaliação das metodologias M.I.C.E.®, Etest® e microdiluição em caldo para determinação da CIM em isolados clínicos Evaluation of M.I.C.E.TM, Etest® and CLSI broth microdilution methods for antimicrobial susceptibility testing of nosocomial bacterial isolates

INTRODUÇÃO: As fitas Oxoid® M.I.C.Evaluator® (M.I.C.E., Thermo Fisher Scientific, Basingstoke, UK), recém-lançadas no mercado brasileiro, representam uma alternativa rápida para a realização de testes de sensibilidade a antimicrobianos (TSA). OBJETIVO: Avaliar o desempenho da metodologia M.I.C.E. em...

Full description

Bibliographic Details
Main Authors: Eloiza Helena Campana, Cecília Godoy Carvalhaes, Paula Peraro Barbosa, Antonia Maria de Oliveira Machado, Ana Maria de Paula, Ana Cristina Gales
Format: Article
Language:English
Published: Sociedade Brasileira de Patologia Clínica 2011-04-01
Series:Jornal Brasileiro de Patologia e Medicina Laboratorial
Subjects:
Online Access:http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1676-24442011000200011
id doaj-5691fbec23bc49108454e6e315836939
record_format Article
collection DOAJ
language English
format Article
sources DOAJ
author Eloiza Helena Campana
Cecília Godoy Carvalhaes
Paula Peraro Barbosa
Antonia Maria de Oliveira Machado
Ana Maria de Paula
Ana Cristina Gales
spellingShingle Eloiza Helena Campana
Cecília Godoy Carvalhaes
Paula Peraro Barbosa
Antonia Maria de Oliveira Machado
Ana Maria de Paula
Ana Cristina Gales
Avaliação das metodologias M.I.C.E.®, Etest® e microdiluição em caldo para determinação da CIM em isolados clínicos Evaluation of M.I.C.E.TM, Etest® and CLSI broth microdilution methods for antimicrobial susceptibility testing of nosocomial bacterial isolates
Jornal Brasileiro de Patologia e Medicina Laboratorial
Concentração inibitória mínima
Antimicrobianos
Teste de sensibilidade a antimicrobianos
Etest
M.I.C.E
Minimal inhibitory concentration
Antimicrobial
Antimicrobial susceptibility testing
Etest
M.I.C.E
author_facet Eloiza Helena Campana
Cecília Godoy Carvalhaes
Paula Peraro Barbosa
Antonia Maria de Oliveira Machado
Ana Maria de Paula
Ana Cristina Gales
author_sort Eloiza Helena Campana
title Avaliação das metodologias M.I.C.E.®, Etest® e microdiluição em caldo para determinação da CIM em isolados clínicos Evaluation of M.I.C.E.TM, Etest® and CLSI broth microdilution methods for antimicrobial susceptibility testing of nosocomial bacterial isolates
title_short Avaliação das metodologias M.I.C.E.®, Etest® e microdiluição em caldo para determinação da CIM em isolados clínicos Evaluation of M.I.C.E.TM, Etest® and CLSI broth microdilution methods for antimicrobial susceptibility testing of nosocomial bacterial isolates
title_full Avaliação das metodologias M.I.C.E.®, Etest® e microdiluição em caldo para determinação da CIM em isolados clínicos Evaluation of M.I.C.E.TM, Etest® and CLSI broth microdilution methods for antimicrobial susceptibility testing of nosocomial bacterial isolates
title_fullStr Avaliação das metodologias M.I.C.E.®, Etest® e microdiluição em caldo para determinação da CIM em isolados clínicos Evaluation of M.I.C.E.TM, Etest® and CLSI broth microdilution methods for antimicrobial susceptibility testing of nosocomial bacterial isolates
title_full_unstemmed Avaliação das metodologias M.I.C.E.®, Etest® e microdiluição em caldo para determinação da CIM em isolados clínicos Evaluation of M.I.C.E.TM, Etest® and CLSI broth microdilution methods for antimicrobial susceptibility testing of nosocomial bacterial isolates
title_sort avaliação das metodologias m.i.c.e.®, etest® e microdiluição em caldo para determinação da cim em isolados clínicos evaluation of m.i.c.e.tm, etest® and clsi broth microdilution methods for antimicrobial susceptibility testing of nosocomial bacterial isolates
publisher Sociedade Brasileira de Patologia Clínica
series Jornal Brasileiro de Patologia e Medicina Laboratorial
issn 1676-2444
1678-4774
publishDate 2011-04-01
description INTRODUÇÃO: As fitas Oxoid® M.I.C.Evaluator® (M.I.C.E., Thermo Fisher Scientific, Basingstoke, UK), recém-lançadas no mercado brasileiro, representam uma alternativa rápida para a realização de testes de sensibilidade a antimicrobianos (TSA). OBJETIVO: Avaliar o desempenho da metodologia M.I.C.E. em relação à microdiluição em caldo (teste de referência) e ao Etest® (BioMérieux, Marcy l'Étoile, France). Material e métodos: Foram selecionados 160 isolados bacterianos, sendo P. aeruginosa (20), Acinetobacter spp. (20), K. pneumoniae (20), E. coli (20), S. aureus (20), Staphylococcus coagulase-negativa (20), E. faecalis (20) e E. faecium (20). Os TSAs foram realizados por microdiluição em caldo, Etest e M.I.C.E., seguindo-se as recomendações do Clinical Laboratory Standards Institute (CLSI, 2009) e dos respectivos fabricantes. Os resultados foram interpretados segundo os critérios estabelecidos pelo CLSI e comparados por análise de regressão. RESULTADOS: Avaliando-se todas as combinações de antimicrobianos vs. a espécie bacteriana, o desempenho da metodologia M.I.C.E. foi muito bom, apresentando uma concordância geral (variação na concentração inibitória mínima [CIM] ± 1-log2) > 90%, exceto para cefotaxima (85%) e vancomicina (76,3%), quando em comparação com os resultados da metodologia de referência. Quando comparado com o Etest, a metodologia M.I.C.E. apresentou concordância geral > 96%, com exceção para a combinação amoxicilina/ácido clavulânico (67,5%). CONCLUSÃO: Os resultados do TSA obtidos pela metodologia M.I.C.E. apresentaram boa correlação com aqueles obtidos pela microdiluição em caldo e pelo Etest, indicando que essa metodologia é uma alternativa rápida para a determinação da CIM pelos laboratórios de microbiologia clínica. Atenção especial deve ser dada á determinação da CIM para a combinação amoxicilina/ácido clavulânico.<br>INTRODUCTION: The Oxoid® M.I.C.EvaluatorTM methodology (M.I.C.E., Thermo Fisher Scientific, Basingstoke, UK), recently released into the market, represents a rapid alternative to antimicrobial susceptibility testing. OBJECTIVE: The objective of this study was to evaluate the performance of M.I.C.E. methodology in relation to broth microdilution (reference test) and Etest® (BioMérieux, Marcy l'Étoile, France). Material and method: A total of 160 bacterial isolates were collected comprising the following species: P. aeruginosa (20), Acinetobacter spp. (20), K. pneumoniae (20), E. coli (20), S. aureus (20), coagulase-negative Staphylococcus (20), E. faecalis (20) and E. faecium (20). Following Clinical Laboratory Standands Institute (CLSI) standards (2009) and the manufacturers' recommendations, antimicrobial susceptibility testing was performed using broth microdilution method, Etest and M.I.C.E. The results were interpreted according to the criteria established by CLSI and compared through regression analysis. RESULTS: All antimicrobial combinations vs. bacterial species were evaluated and M.I.C.E. methodology yielded good results with general correlation (MIC variation ± 1-log2) > 90%, except for cefotaxime (85%) and vancomycin (76.3%) when compared with the reference method. The M.I.C.E. results compared to Etest showed general correlation (> 96%), except for amoxicillin/clavulanic acid (67.5%) combination. CONCLUSION: AST results obtained from M.I.C.E. methodology showed a good correlation with those from broth microdilution and Etest, which corroborates its time effectiveness in the determination of MIC. However, the combination of amoxicillin/clavulanic acid requires further attention.
topic Concentração inibitória mínima
Antimicrobianos
Teste de sensibilidade a antimicrobianos
Etest
M.I.C.E
Minimal inhibitory concentration
Antimicrobial
Antimicrobial susceptibility testing
Etest
M.I.C.E
url http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1676-24442011000200011
work_keys_str_mv AT eloizahelenacampana avaliacaodasmetodologiasmiceetestemicrodiluicaoemcaldoparadeterminacaodacimemisoladosclinicosevaluationofmicetmetestandclsibrothmicrodilutionmethodsforantimicrobialsusceptibilitytestingofnosocomialbacterialisolates
AT ceciliagodoycarvalhaes avaliacaodasmetodologiasmiceetestemicrodiluicaoemcaldoparadeterminacaodacimemisoladosclinicosevaluationofmicetmetestandclsibrothmicrodilutionmethodsforantimicrobialsusceptibilitytestingofnosocomialbacterialisolates
AT paulaperarobarbosa avaliacaodasmetodologiasmiceetestemicrodiluicaoemcaldoparadeterminacaodacimemisoladosclinicosevaluationofmicetmetestandclsibrothmicrodilutionmethodsforantimicrobialsusceptibilitytestingofnosocomialbacterialisolates
AT antoniamariadeoliveiramachado avaliacaodasmetodologiasmiceetestemicrodiluicaoemcaldoparadeterminacaodacimemisoladosclinicosevaluationofmicetmetestandclsibrothmicrodilutionmethodsforantimicrobialsusceptibilitytestingofnosocomialbacterialisolates
AT anamariadepaula avaliacaodasmetodologiasmiceetestemicrodiluicaoemcaldoparadeterminacaodacimemisoladosclinicosevaluationofmicetmetestandclsibrothmicrodilutionmethodsforantimicrobialsusceptibilitytestingofnosocomialbacterialisolates
AT anacristinagales avaliacaodasmetodologiasmiceetestemicrodiluicaoemcaldoparadeterminacaodacimemisoladosclinicosevaluationofmicetmetestandclsibrothmicrodilutionmethodsforantimicrobialsusceptibilitytestingofnosocomialbacterialisolates
_version_ 1725613205732982784
spelling doaj-5691fbec23bc49108454e6e3158369392020-11-24T23:08:37ZengSociedade Brasileira de Patologia ClínicaJornal Brasileiro de Patologia e Medicina Laboratorial1676-24441678-47742011-04-0147215716410.1590/S1676-24442011000200011Avaliação das metodologias M.I.C.E.®, Etest® e microdiluição em caldo para determinação da CIM em isolados clínicos Evaluation of M.I.C.E.TM, Etest® and CLSI broth microdilution methods for antimicrobial susceptibility testing of nosocomial bacterial isolatesEloiza Helena CampanaCecília Godoy CarvalhaesPaula Peraro BarbosaAntonia Maria de Oliveira MachadoAna Maria de PaulaAna Cristina GalesINTRODUÇÃO: As fitas Oxoid® M.I.C.Evaluator® (M.I.C.E., Thermo Fisher Scientific, Basingstoke, UK), recém-lançadas no mercado brasileiro, representam uma alternativa rápida para a realização de testes de sensibilidade a antimicrobianos (TSA). OBJETIVO: Avaliar o desempenho da metodologia M.I.C.E. em relação à microdiluição em caldo (teste de referência) e ao Etest® (BioMérieux, Marcy l'Étoile, France). Material e métodos: Foram selecionados 160 isolados bacterianos, sendo P. aeruginosa (20), Acinetobacter spp. (20), K. pneumoniae (20), E. coli (20), S. aureus (20), Staphylococcus coagulase-negativa (20), E. faecalis (20) e E. faecium (20). Os TSAs foram realizados por microdiluição em caldo, Etest e M.I.C.E., seguindo-se as recomendações do Clinical Laboratory Standards Institute (CLSI, 2009) e dos respectivos fabricantes. Os resultados foram interpretados segundo os critérios estabelecidos pelo CLSI e comparados por análise de regressão. RESULTADOS: Avaliando-se todas as combinações de antimicrobianos vs. a espécie bacteriana, o desempenho da metodologia M.I.C.E. foi muito bom, apresentando uma concordância geral (variação na concentração inibitória mínima [CIM] ± 1-log2) > 90%, exceto para cefotaxima (85%) e vancomicina (76,3%), quando em comparação com os resultados da metodologia de referência. Quando comparado com o Etest, a metodologia M.I.C.E. apresentou concordância geral > 96%, com exceção para a combinação amoxicilina/ácido clavulânico (67,5%). CONCLUSÃO: Os resultados do TSA obtidos pela metodologia M.I.C.E. apresentaram boa correlação com aqueles obtidos pela microdiluição em caldo e pelo Etest, indicando que essa metodologia é uma alternativa rápida para a determinação da CIM pelos laboratórios de microbiologia clínica. Atenção especial deve ser dada á determinação da CIM para a combinação amoxicilina/ácido clavulânico.<br>INTRODUCTION: The Oxoid® M.I.C.EvaluatorTM methodology (M.I.C.E., Thermo Fisher Scientific, Basingstoke, UK), recently released into the market, represents a rapid alternative to antimicrobial susceptibility testing. OBJECTIVE: The objective of this study was to evaluate the performance of M.I.C.E. methodology in relation to broth microdilution (reference test) and Etest® (BioMérieux, Marcy l'Étoile, France). Material and method: A total of 160 bacterial isolates were collected comprising the following species: P. aeruginosa (20), Acinetobacter spp. (20), K. pneumoniae (20), E. coli (20), S. aureus (20), coagulase-negative Staphylococcus (20), E. faecalis (20) and E. faecium (20). Following Clinical Laboratory Standands Institute (CLSI) standards (2009) and the manufacturers' recommendations, antimicrobial susceptibility testing was performed using broth microdilution method, Etest and M.I.C.E. The results were interpreted according to the criteria established by CLSI and compared through regression analysis. RESULTS: All antimicrobial combinations vs. bacterial species were evaluated and M.I.C.E. methodology yielded good results with general correlation (MIC variation ± 1-log2) > 90%, except for cefotaxime (85%) and vancomycin (76.3%) when compared with the reference method. The M.I.C.E. results compared to Etest showed general correlation (> 96%), except for amoxicillin/clavulanic acid (67.5%) combination. CONCLUSION: AST results obtained from M.I.C.E. methodology showed a good correlation with those from broth microdilution and Etest, which corroborates its time effectiveness in the determination of MIC. However, the combination of amoxicillin/clavulanic acid requires further attention.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1676-24442011000200011Concentração inibitória mínimaAntimicrobianosTeste de sensibilidade a antimicrobianosEtestM.I.C.EMinimal inhibitory concentrationAntimicrobialAntimicrobial susceptibility testingEtestM.I.C.E