A Bench Evaluation Test for Refrigeration Oils in a Refrigeration System Using a Screw Compressor
Refrigeration oil has a large effect on the performance of refrigeration systems. However, the physical and chemical indexes of fresh refrigeration oils often fail to reflect the actual operating characteristics, especially with respect to the degradation of refrigeration oils. In this paper, a benc...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2019-08-01
|
Series: | Applied Sciences |
Subjects: | |
Online Access: | https://www.mdpi.com/2076-3417/9/15/3202 |
id |
doaj-56f9faef9c974baeb7500d8bf540ac4a |
---|---|
record_format |
Article |
spelling |
doaj-56f9faef9c974baeb7500d8bf540ac4a2020-11-25T01:57:17ZengMDPI AGApplied Sciences2076-34172019-08-01915320210.3390/app9153202app9153202A Bench Evaluation Test for Refrigeration Oils in a Refrigeration System Using a Screw CompressorWeifeng Wu0Zhao Zhang1Xiaolin Wang2Liangwei Yang3Quanke Feng4School of Energy and Power Engineering, Xi’an Jiaotong University, Xi’an 710049, ChinaSchool of Energy and Power Engineering, Xi’an Jiaotong University, Xi’an 710049, ChinaSchool of Engineering, University of Tasmania, Hobart TAS7001, AustraliaSchool of Energy and Power Engineering, Xi’an Jiaotong University, Xi’an 710049, ChinaSchool of Energy and Power Engineering, Xi’an Jiaotong University, Xi’an 710049, ChinaRefrigeration oil has a large effect on the performance of refrigeration systems. However, the physical and chemical indexes of fresh refrigeration oils often fail to reflect the actual operating characteristics, especially with respect to the degradation of refrigeration oils. In this paper, a bench evaluation test of refrigeration oils was carried out to investigate the degradation of synthetic refrigeration oils used with the refrigerant R134a, in a purpose-built, full-scale refrigeration system utilizing a screw compressor. To accelerate the degradation process of the refrigeration oil, the discharge temperature at the exit of the compressor was turned to a high level. Comparison tests of a mature refrigeration oil type A and a newly developed oil type B were performed under the same working conditions with 500 h of operating time. The performance of the screw compressor and refrigeration system was analyzed. The abrasion of the screw rotors and carbon deposition at the discharge port was investigated. Results showed that the bench evaluation test successfully predicted the degradation process of the refrigeration oils. The evolution analysis of the refrigeration oil viscosity and acid value during the bench evaluation test indicated that 15% of the physical and chemical indexes for refrigeration oil drain were too strict. Research work in this paper showed a more practical method to evaluate the performance of refrigeration oils through the bench evaluation test.https://www.mdpi.com/2076-3417/9/15/3202refrigeration oilscrew compressordegradationbench evaluation |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Weifeng Wu Zhao Zhang Xiaolin Wang Liangwei Yang Quanke Feng |
spellingShingle |
Weifeng Wu Zhao Zhang Xiaolin Wang Liangwei Yang Quanke Feng A Bench Evaluation Test for Refrigeration Oils in a Refrigeration System Using a Screw Compressor Applied Sciences refrigeration oil screw compressor degradation bench evaluation |
author_facet |
Weifeng Wu Zhao Zhang Xiaolin Wang Liangwei Yang Quanke Feng |
author_sort |
Weifeng Wu |
title |
A Bench Evaluation Test for Refrigeration Oils in a Refrigeration System Using a Screw Compressor |
title_short |
A Bench Evaluation Test for Refrigeration Oils in a Refrigeration System Using a Screw Compressor |
title_full |
A Bench Evaluation Test for Refrigeration Oils in a Refrigeration System Using a Screw Compressor |
title_fullStr |
A Bench Evaluation Test for Refrigeration Oils in a Refrigeration System Using a Screw Compressor |
title_full_unstemmed |
A Bench Evaluation Test for Refrigeration Oils in a Refrigeration System Using a Screw Compressor |
title_sort |
bench evaluation test for refrigeration oils in a refrigeration system using a screw compressor |
publisher |
MDPI AG |
series |
Applied Sciences |
issn |
2076-3417 |
publishDate |
2019-08-01 |
description |
Refrigeration oil has a large effect on the performance of refrigeration systems. However, the physical and chemical indexes of fresh refrigeration oils often fail to reflect the actual operating characteristics, especially with respect to the degradation of refrigeration oils. In this paper, a bench evaluation test of refrigeration oils was carried out to investigate the degradation of synthetic refrigeration oils used with the refrigerant R134a, in a purpose-built, full-scale refrigeration system utilizing a screw compressor. To accelerate the degradation process of the refrigeration oil, the discharge temperature at the exit of the compressor was turned to a high level. Comparison tests of a mature refrigeration oil type A and a newly developed oil type B were performed under the same working conditions with 500 h of operating time. The performance of the screw compressor and refrigeration system was analyzed. The abrasion of the screw rotors and carbon deposition at the discharge port was investigated. Results showed that the bench evaluation test successfully predicted the degradation process of the refrigeration oils. The evolution analysis of the refrigeration oil viscosity and acid value during the bench evaluation test indicated that 15% of the physical and chemical indexes for refrigeration oil drain were too strict. Research work in this paper showed a more practical method to evaluate the performance of refrigeration oils through the bench evaluation test. |
topic |
refrigeration oil screw compressor degradation bench evaluation |
url |
https://www.mdpi.com/2076-3417/9/15/3202 |
work_keys_str_mv |
AT weifengwu abenchevaluationtestforrefrigerationoilsinarefrigerationsystemusingascrewcompressor AT zhaozhang abenchevaluationtestforrefrigerationoilsinarefrigerationsystemusingascrewcompressor AT xiaolinwang abenchevaluationtestforrefrigerationoilsinarefrigerationsystemusingascrewcompressor AT liangweiyang abenchevaluationtestforrefrigerationoilsinarefrigerationsystemusingascrewcompressor AT quankefeng abenchevaluationtestforrefrigerationoilsinarefrigerationsystemusingascrewcompressor AT weifengwu benchevaluationtestforrefrigerationoilsinarefrigerationsystemusingascrewcompressor AT zhaozhang benchevaluationtestforrefrigerationoilsinarefrigerationsystemusingascrewcompressor AT xiaolinwang benchevaluationtestforrefrigerationoilsinarefrigerationsystemusingascrewcompressor AT liangweiyang benchevaluationtestforrefrigerationoilsinarefrigerationsystemusingascrewcompressor AT quankefeng benchevaluationtestforrefrigerationoilsinarefrigerationsystemusingascrewcompressor |
_version_ |
1724975006881939456 |