Reflected wave intensity increases based on aortic diameter after endovascular aortic therapy in a goat model

Abstract Reflected wave increases after endovascular aortic repair (EVAR) in patients with aortic aneurysm. This affects the left ventricular (LV) diastolic function and leads to a poor prognosis. This study aimed to evaluate the relationship between increased reflected wave amplitude and aortic dia...

Full description

Bibliographic Details
Main Authors: Tomohiro Takano, Masumi Iwai-Takano, Yusuke Tsuboko, Yasuyuki Shiraishi, Tomoyuki Yambe, Takashi Igarashi, Hitoshi Yokoyama
Format: Article
Language:English
Published: Nature Publishing Group 2021-02-01
Series:Scientific Reports
Online Access:https://doi.org/10.1038/s41598-020-80920-y
id doaj-57f3588c1f6040ea9f522b141bf33797
record_format Article
spelling doaj-57f3588c1f6040ea9f522b141bf337972021-02-21T12:30:41ZengNature Publishing GroupScientific Reports2045-23222021-02-011111910.1038/s41598-020-80920-yReflected wave intensity increases based on aortic diameter after endovascular aortic therapy in a goat modelTomohiro Takano0Masumi Iwai-Takano1Yusuke Tsuboko2Yasuyuki Shiraishi3Tomoyuki Yambe4Takashi Igarashi5Hitoshi Yokoyama6Department of Cardiovascular Surgery, Fukushima Medical UniversityDepartment of Cardiovascular Surgery, Fukushima Medical UniversityWaseda Research Institute for Science and Engineering, Waseda UniversityInstitute of Development Aging and Cancer, Tohoku UniversityInstitute of Development Aging and Cancer, Tohoku UniversityDepartment of Cardiovascular Surgery, Fukushima Medical UniversityDepartment of Cardiovascular Surgery, Fukushima Medical UniversityAbstract Reflected wave increases after endovascular aortic repair (EVAR) in patients with aortic aneurysm. This affects the left ventricular (LV) diastolic function and leads to a poor prognosis. This study aimed to evaluate the relationship between increased reflected wave amplitude and aortic diameter after EVAR. EVAR was performed in seven healthy goats. We assessed wave intensity (WI), aortic diameter, and stiffness parameter β. Moreover, we evaluated the relationship between negative reflected wave (NW, reflected waves toward the heart from the periphery by WI) and other parameters after EVAR. Results showed an increase in stiffness parameter β (3.5 ± 0.3 vs 15.9 ± 4.7, p = 0.018) and a decrease in the change of aortic diameter (6.9 ± 0.7 vs 2.7 ± 0.4%, p = 0.018) after EVAR. The NW was significantly amplified after EVAR from baseline (−589.8 ± 143.4 to  − 1192.3 ± 303.7 mmHg-m/sec3, p = 0.043). The NW showed a significant correlation with maximum aortic diameter (R = 0.707, p = 0.038) and minimum aortic diameter (R = 0.724, p = 0.033). The reflected wave was enhanced after EVAR and was correlated to the aortic diameter at the stent-graft site. It is important to consider that patients with smaller aortic diameters in landing zone who undergo EVAR may develop LV dysfunction.https://doi.org/10.1038/s41598-020-80920-y
collection DOAJ
language English
format Article
sources DOAJ
author Tomohiro Takano
Masumi Iwai-Takano
Yusuke Tsuboko
Yasuyuki Shiraishi
Tomoyuki Yambe
Takashi Igarashi
Hitoshi Yokoyama
spellingShingle Tomohiro Takano
Masumi Iwai-Takano
Yusuke Tsuboko
Yasuyuki Shiraishi
Tomoyuki Yambe
Takashi Igarashi
Hitoshi Yokoyama
Reflected wave intensity increases based on aortic diameter after endovascular aortic therapy in a goat model
Scientific Reports
author_facet Tomohiro Takano
Masumi Iwai-Takano
Yusuke Tsuboko
Yasuyuki Shiraishi
Tomoyuki Yambe
Takashi Igarashi
Hitoshi Yokoyama
author_sort Tomohiro Takano
title Reflected wave intensity increases based on aortic diameter after endovascular aortic therapy in a goat model
title_short Reflected wave intensity increases based on aortic diameter after endovascular aortic therapy in a goat model
title_full Reflected wave intensity increases based on aortic diameter after endovascular aortic therapy in a goat model
title_fullStr Reflected wave intensity increases based on aortic diameter after endovascular aortic therapy in a goat model
title_full_unstemmed Reflected wave intensity increases based on aortic diameter after endovascular aortic therapy in a goat model
title_sort reflected wave intensity increases based on aortic diameter after endovascular aortic therapy in a goat model
publisher Nature Publishing Group
series Scientific Reports
issn 2045-2322
publishDate 2021-02-01
description Abstract Reflected wave increases after endovascular aortic repair (EVAR) in patients with aortic aneurysm. This affects the left ventricular (LV) diastolic function and leads to a poor prognosis. This study aimed to evaluate the relationship between increased reflected wave amplitude and aortic diameter after EVAR. EVAR was performed in seven healthy goats. We assessed wave intensity (WI), aortic diameter, and stiffness parameter β. Moreover, we evaluated the relationship between negative reflected wave (NW, reflected waves toward the heart from the periphery by WI) and other parameters after EVAR. Results showed an increase in stiffness parameter β (3.5 ± 0.3 vs 15.9 ± 4.7, p = 0.018) and a decrease in the change of aortic diameter (6.9 ± 0.7 vs 2.7 ± 0.4%, p = 0.018) after EVAR. The NW was significantly amplified after EVAR from baseline (−589.8 ± 143.4 to  − 1192.3 ± 303.7 mmHg-m/sec3, p = 0.043). The NW showed a significant correlation with maximum aortic diameter (R = 0.707, p = 0.038) and minimum aortic diameter (R = 0.724, p = 0.033). The reflected wave was enhanced after EVAR and was correlated to the aortic diameter at the stent-graft site. It is important to consider that patients with smaller aortic diameters in landing zone who undergo EVAR may develop LV dysfunction.
url https://doi.org/10.1038/s41598-020-80920-y
work_keys_str_mv AT tomohirotakano reflectedwaveintensityincreasesbasedonaorticdiameterafterendovascularaortictherapyinagoatmodel
AT masumiiwaitakano reflectedwaveintensityincreasesbasedonaorticdiameterafterendovascularaortictherapyinagoatmodel
AT yusuketsuboko reflectedwaveintensityincreasesbasedonaorticdiameterafterendovascularaortictherapyinagoatmodel
AT yasuyukishiraishi reflectedwaveintensityincreasesbasedonaorticdiameterafterendovascularaortictherapyinagoatmodel
AT tomoyukiyambe reflectedwaveintensityincreasesbasedonaorticdiameterafterendovascularaortictherapyinagoatmodel
AT takashiigarashi reflectedwaveintensityincreasesbasedonaorticdiameterafterendovascularaortictherapyinagoatmodel
AT hitoshiyokoyama reflectedwaveintensityincreasesbasedonaorticdiameterafterendovascularaortictherapyinagoatmodel
_version_ 1724258033150722048