Admixtures in spent plutonium sources and gamma-radiation

The isotopic composition of several spent smoke detectors containing plutonium has been investigated. The article also presents the calculated results of 241Am and 241Pu activities in smoke detectors. The received values vary from (0.934±0.028) MBq to (91.2±4.6) MBq. The eguivalent dose rate of the...

Full description

Bibliographic Details
Main Authors: Inga Pelanytė, Stasys Motiejūnas, Arūnas Gudelis
Format: Article
Language:English
Published: Vilnius Gediminas Technical University 2011-04-01
Series:Mokslas: Lietuvos Ateitis
Subjects:
Online Access:https://www.jbem.vgtu.lt/index.php/MLA/article/view/10692
id doaj-586bbca4a93f4a2dbb547aea59f3265c
record_format Article
spelling doaj-586bbca4a93f4a2dbb547aea59f3265c2021-05-02T03:28:30ZengVilnius Gediminas Technical UniversityMokslas: Lietuvos Ateitis2029-23412029-22522011-04-011410.3846/mla.2009.4.08161Admixtures in spent plutonium sources and gamma-radiationInga Pelanytė0Stasys Motiejūnas1Arūnas Gudelis2Vilniaus Gedimino technikos universitetas, LithuaniaVilniaus Gedimino technikos universitetas, LithuaniaVilniaus Gedimino technikos universitetas, Lithuania The isotopic composition of several spent smoke detectors containing plutonium has been investigated. The article also presents the calculated results of 241Am and 241Pu activities in smoke detectors. The received values vary from (0.934±0.028) MBq to (91.2±4.6) MBq. The eguivalent dose rate of the established gamma radiation vary from 220 nSv/h to 500 nSv/h. A dose caused by artificial radionuclides in spent smoke detectors was evaluated and compared in the article. It has been found out that due to smoke detectors, an annual dose varies from 0.06 mSv to 0.31 mSv. Article in Lithuanian. Priemaišos naudotuose plutonio šaltiniuose ir gama spinduliuotė Anotacija. Šiame darbe nagrinėjama naudotų plutonio šaltinių izotopinė sudėtis ir galimų priemaišinių radionuklidų įtaka žmonių saugai. Pateikti radionuklidų americio 241Am ir plutonio 241Pu aktyvumo dūmų jutikliuose skaičiavimo rezultatai. Gautos vertės kinta nuo 0,934±0,028 MBq iki 91,2±4,6 MBq. Išmatuota gama spinduliuotės sukelta lygiavertės dozės galia. Nustatytos lygiavertės dozės galios vertės kinta nuo 220 nSv/h iki 500 nSv/h. Vidutinė dozės galia patalpoje yra apie 140 nSv/h. Įvertinta išorinė apšvita, sukelta dirbtinės kilmės americio 241Am radionuklidų, esančių naudotuose dūmų jutikliuose. Nustatyta, kad metinė išorinė apšvita žmogui, dirbančiam patalpoje, kurioje įmontuotas dūmų jutiklis, kinta nuo 0,06 mSv iki 0,31 mSv. Reikšminiai žodžiai: dūmų jutikliai, gama spektrometriniai tyrimai, aktyvumas, išorinė gama apšvita.   https://www.jbem.vgtu.lt/index.php/MLA/article/view/10692smoke detectorsgama spectrometric researchactivityexternal gama irradiance
collection DOAJ
language English
format Article
sources DOAJ
author Inga Pelanytė
Stasys Motiejūnas
Arūnas Gudelis
spellingShingle Inga Pelanytė
Stasys Motiejūnas
Arūnas Gudelis
Admixtures in spent plutonium sources and gamma-radiation
Mokslas: Lietuvos Ateitis
smoke detectors
gama spectrometric research
activity
external gama irradiance
author_facet Inga Pelanytė
Stasys Motiejūnas
Arūnas Gudelis
author_sort Inga Pelanytė
title Admixtures in spent plutonium sources and gamma-radiation
title_short Admixtures in spent plutonium sources and gamma-radiation
title_full Admixtures in spent plutonium sources and gamma-radiation
title_fullStr Admixtures in spent plutonium sources and gamma-radiation
title_full_unstemmed Admixtures in spent plutonium sources and gamma-radiation
title_sort admixtures in spent plutonium sources and gamma-radiation
publisher Vilnius Gediminas Technical University
series Mokslas: Lietuvos Ateitis
issn 2029-2341
2029-2252
publishDate 2011-04-01
description The isotopic composition of several spent smoke detectors containing plutonium has been investigated. The article also presents the calculated results of 241Am and 241Pu activities in smoke detectors. The received values vary from (0.934±0.028) MBq to (91.2±4.6) MBq. The eguivalent dose rate of the established gamma radiation vary from 220 nSv/h to 500 nSv/h. A dose caused by artificial radionuclides in spent smoke detectors was evaluated and compared in the article. It has been found out that due to smoke detectors, an annual dose varies from 0.06 mSv to 0.31 mSv. Article in Lithuanian. Priemaišos naudotuose plutonio šaltiniuose ir gama spinduliuotė Anotacija. Šiame darbe nagrinėjama naudotų plutonio šaltinių izotopinė sudėtis ir galimų priemaišinių radionuklidų įtaka žmonių saugai. Pateikti radionuklidų americio 241Am ir plutonio 241Pu aktyvumo dūmų jutikliuose skaičiavimo rezultatai. Gautos vertės kinta nuo 0,934±0,028 MBq iki 91,2±4,6 MBq. Išmatuota gama spinduliuotės sukelta lygiavertės dozės galia. Nustatytos lygiavertės dozės galios vertės kinta nuo 220 nSv/h iki 500 nSv/h. Vidutinė dozės galia patalpoje yra apie 140 nSv/h. Įvertinta išorinė apšvita, sukelta dirbtinės kilmės americio 241Am radionuklidų, esančių naudotuose dūmų jutikliuose. Nustatyta, kad metinė išorinė apšvita žmogui, dirbančiam patalpoje, kurioje įmontuotas dūmų jutiklis, kinta nuo 0,06 mSv iki 0,31 mSv. Reikšminiai žodžiai: dūmų jutikliai, gama spektrometriniai tyrimai, aktyvumas, išorinė gama apšvita.  
topic smoke detectors
gama spectrometric research
activity
external gama irradiance
url https://www.jbem.vgtu.lt/index.php/MLA/article/view/10692
work_keys_str_mv AT ingapelanyte admixturesinspentplutoniumsourcesandgammaradiation
AT stasysmotiejunas admixturesinspentplutoniumsourcesandgammaradiation
AT arunasgudelis admixturesinspentplutoniumsourcesandgammaradiation
_version_ 1721495616524124160