Corrosion monitoring of the reinforced concrete by using the embedded annular piezoelectric transducer

It is an important issue to ensure the long-term reliable service of the reinforced concrete structures by developing effective online monitoring techniques. In this paper, three different accelerated corrosion experiments were conducted by using the electrochemical method, and the ultrasonic pitch-...

Full description

Bibliographic Details
Main Authors: Peng Liu, Yan Hu, Bo Geng, Dongyu Xu
Format: Article
Language:English
Published: Elsevier 2020-05-01
Series:Journal of Materials Research and Technology
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S2238785419322720
id doaj-59598865e23f42a981c27e543269671e
record_format Article
spelling doaj-59598865e23f42a981c27e543269671e2020-11-25T03:46:45ZengElsevierJournal of Materials Research and Technology2238-78542020-05-019335113519Corrosion monitoring of the reinforced concrete by using the embedded annular piezoelectric transducerPeng Liu0Yan Hu1Bo Geng2Dongyu Xu3School of Civil Engineering, Central South University, Changsha, Hunan 410075, ChinaSchool of Civil Engineering, Central South University, Changsha, Hunan 410075, China; Corresponding author.Shandong Provincial Key Laboratory of Construction Materials Preparation and Measurement, University of Jinan, Jinan, Shandong 250022, ChinaShandong Provincial Key Laboratory of Construction Materials Preparation and Measurement, University of Jinan, Jinan, Shandong 250022, China; Corresponding author.It is an important issue to ensure the long-term reliable service of the reinforced concrete structures by developing effective online monitoring techniques. In this paper, three different accelerated corrosion experiments were conducted by using the electrochemical method, and the ultrasonic pitch-catch and the electrochemical impedance spectroscopy methods were employed to discuss the corrosion phenomena by using the embedded annular piezoelectric ultrasonic transducer. The results show that the capacitance arc length in the high frequency zone of the electrochemical impedance spectra increases gradually with increasing the corrosion rate. When the corrosion rate is larger than 3%, obvious corrosion products can be found on surface of the reinforced concrete, and there exist two capacitance arcs in the corresponding electrochemical impedance spectra. The ultrasonic analysis results show that there is an obvious longitudinal mode wave packet in the time domain spectra, and the peak-peak value shows a linear decreasing trend with increasing the corrosion time. The dominant frequency peak value also decreases with increasing the corrosion time accompanying with the appearances of the new peaks in the low frequency zone. The wavelet transform method was also employed for the ultrasonic time-frequency domain analysis. Based on variations of the acoustic energy and dominant frequency components of the ultrasonic wave, the corrosion extent of the reinforced concrete can be qualitatively evaluated.http://www.sciencedirect.com/science/article/pii/S2238785419322720ConcreteCorrosionUltrasonicPiezoelectricTransducer
collection DOAJ
language English
format Article
sources DOAJ
author Peng Liu
Yan Hu
Bo Geng
Dongyu Xu
spellingShingle Peng Liu
Yan Hu
Bo Geng
Dongyu Xu
Corrosion monitoring of the reinforced concrete by using the embedded annular piezoelectric transducer
Journal of Materials Research and Technology
Concrete
Corrosion
Ultrasonic
Piezoelectric
Transducer
author_facet Peng Liu
Yan Hu
Bo Geng
Dongyu Xu
author_sort Peng Liu
title Corrosion monitoring of the reinforced concrete by using the embedded annular piezoelectric transducer
title_short Corrosion monitoring of the reinforced concrete by using the embedded annular piezoelectric transducer
title_full Corrosion monitoring of the reinforced concrete by using the embedded annular piezoelectric transducer
title_fullStr Corrosion monitoring of the reinforced concrete by using the embedded annular piezoelectric transducer
title_full_unstemmed Corrosion monitoring of the reinforced concrete by using the embedded annular piezoelectric transducer
title_sort corrosion monitoring of the reinforced concrete by using the embedded annular piezoelectric transducer
publisher Elsevier
series Journal of Materials Research and Technology
issn 2238-7854
publishDate 2020-05-01
description It is an important issue to ensure the long-term reliable service of the reinforced concrete structures by developing effective online monitoring techniques. In this paper, three different accelerated corrosion experiments were conducted by using the electrochemical method, and the ultrasonic pitch-catch and the electrochemical impedance spectroscopy methods were employed to discuss the corrosion phenomena by using the embedded annular piezoelectric ultrasonic transducer. The results show that the capacitance arc length in the high frequency zone of the electrochemical impedance spectra increases gradually with increasing the corrosion rate. When the corrosion rate is larger than 3%, obvious corrosion products can be found on surface of the reinforced concrete, and there exist two capacitance arcs in the corresponding electrochemical impedance spectra. The ultrasonic analysis results show that there is an obvious longitudinal mode wave packet in the time domain spectra, and the peak-peak value shows a linear decreasing trend with increasing the corrosion time. The dominant frequency peak value also decreases with increasing the corrosion time accompanying with the appearances of the new peaks in the low frequency zone. The wavelet transform method was also employed for the ultrasonic time-frequency domain analysis. Based on variations of the acoustic energy and dominant frequency components of the ultrasonic wave, the corrosion extent of the reinforced concrete can be qualitatively evaluated.
topic Concrete
Corrosion
Ultrasonic
Piezoelectric
Transducer
url http://www.sciencedirect.com/science/article/pii/S2238785419322720
work_keys_str_mv AT pengliu corrosionmonitoringofthereinforcedconcretebyusingtheembeddedannularpiezoelectrictransducer
AT yanhu corrosionmonitoringofthereinforcedconcretebyusingtheembeddedannularpiezoelectrictransducer
AT bogeng corrosionmonitoringofthereinforcedconcretebyusingtheembeddedannularpiezoelectrictransducer
AT dongyuxu corrosionmonitoringofthereinforcedconcretebyusingtheembeddedannularpiezoelectrictransducer
_version_ 1724504396530712576