Are defibrillators less useful in patients with non-ischemic heart disease?

Introduction and Objective: The benefits of implanted defibrillators in patients with ischemic heart disease (IHD) are well known. However, the evidence is less robust in patients with non-ischemic heart disease (non-IHD). We aimed to determine whether patients with non-IHD have a similar incidence...

Full description

Bibliographic Details
Main Authors: Rita Marinheiro, Leonor Parreira, Pedro Amador, Catarina Sá, Tatiana Duarte, Marta Fonseca, José Farinha, Cláudia Lopes, Rui Caria
Format: Article
Language:English
Published: Elsevier 2018-10-01
Series:Revista Portuguesa de Cardiologia (English Edition)
Online Access:http://www.sciencedirect.com/science/article/pii/S217420491830309X
id doaj-59f462305fe84f96a5b8bfa066263a46
record_format Article
collection DOAJ
language English
format Article
sources DOAJ
author Rita Marinheiro
Leonor Parreira
Pedro Amador
Catarina Sá
Tatiana Duarte
Marta Fonseca
José Farinha
Cláudia Lopes
Rui Caria
spellingShingle Rita Marinheiro
Leonor Parreira
Pedro Amador
Catarina Sá
Tatiana Duarte
Marta Fonseca
José Farinha
Cláudia Lopes
Rui Caria
Are defibrillators less useful in patients with non-ischemic heart disease?
Revista Portuguesa de Cardiologia (English Edition)
author_facet Rita Marinheiro
Leonor Parreira
Pedro Amador
Catarina Sá
Tatiana Duarte
Marta Fonseca
José Farinha
Cláudia Lopes
Rui Caria
author_sort Rita Marinheiro
title Are defibrillators less useful in patients with non-ischemic heart disease?
title_short Are defibrillators less useful in patients with non-ischemic heart disease?
title_full Are defibrillators less useful in patients with non-ischemic heart disease?
title_fullStr Are defibrillators less useful in patients with non-ischemic heart disease?
title_full_unstemmed Are defibrillators less useful in patients with non-ischemic heart disease?
title_sort are defibrillators less useful in patients with non-ischemic heart disease?
publisher Elsevier
series Revista Portuguesa de Cardiologia (English Edition)
issn 2174-2049
publishDate 2018-10-01
description Introduction and Objective: The benefits of implanted defibrillators in patients with ischemic heart disease (IHD) are well known. However, the evidence is less robust in patients with non-ischemic heart disease (non-IHD). We aimed to determine whether patients with non-IHD have a similar incidence of appropriate shocks and all-cause mortality compared to those with IHD. Methods: In a retrospective single-center study we analyzed all patients with implantable cardioverter-defibrillators or cardiac resynchronization therapy-defibrillators implanted for primary prevention between 2004 and 2014. The population was divided into two groups: patients with IHD and patients with non-IHD. The composite endpoint was appropriate shock and all-cause mortality. Results: Two hundred and eighty-one patients were studied, of whom 187 (66%) had IHD. Patients with IHD were older, more frequently male and with more cardiovascular risk factors. Mean follow-up was 55±42 months. Thirty-four patients (18%) with IHD and 20 patients (21%) with non-IHD had an appropriate shock (p=0.64). Eighty-nine patients (47%) with IHD and 36 (38%) with non-IHD died during follow-up (p=0.19). The rate of shocks or death over time was similar in patients with IHD and non-IHD according to Kaplan-Meier survival curve analysis (log-rank p=0.10). Conclusion: In this population, there were no differences in appropriate shocks or all-cause mortality in the two groups. Resumo: Introdução e objectivo: O benefício do desfibrilhador implantável está bem demonstrado nos doentes com cardiopatia isquémica. No entanto, a evidência deste benefício é menos robusta em doentes com cardiopatia não isquémica. Pretendeu-se determinar se os doentes com cardiopatia não isquémica apresentavam a mesma incidência de choque apropriado e mortalidade total, comparativamente àqueles com cardiopatia isquémica. Métodos: Estudo retrospetivo, em que foram analisados todos os doentes com cardioversor-desfibrilhador implantável ou terapia de ressincronização cardíaca com desfibrilhador, implantados para prevenção primária, entre 2004 a 2014, num único centro. A população foi dividida em dois grupos: doentes com cardiopatia isquémica e doentes com cardiopatia não isquémica. O endpoint primário combinado foi choque apropriado e morte por qualquer causa. Resultados: Foram estudados 281 doentes, dos quais 187 (66%) apresentavam cardiopatia isquémica. Os doentes com cardiopatia isquémica eram mais velhos, mais frequentemente do género masculino e com maior prevalência de fatores de risco cardiovasculares. O follow-up médio foi de 55±42 meses. Trinta e quatro doentes (18%) com cardiopatia isquémica e 20 doentes (21%) com cardiopatia não isquémica tiveram um choque apropriado (p=0,64). Oitenta e nove doentes (47%) com cardiopatia isquémica e 36 (38%) com cardiopatia não isquémica morreram durante o follow-up (p=0,19). A curva de Kaplan-Meier demonstra que a probabilidade de choque ou morte ao longo do tempo é semelhante nos dois grupos (logrank, p=0,14). Conclusão: Na população estudada, não existiram diferenças na probabilidade de choque apropriado ou na mortalidade total nos doentes com cardiopatia não isquémica comparativamente aqueles com cardiopatia isquémica. Keywords: Implantable defibrillator, Non-ischemic heart disease, Ischemic heart disease, Appropriate shock, Death, Palavras-chave: Cardioversor desfibrilhador implantável, Cardiopatia não isquémica, Cardiopatia isquémica, Choque apropriado, Morte
url http://www.sciencedirect.com/science/article/pii/S217420491830309X
work_keys_str_mv AT ritamarinheiro aredefibrillatorslessusefulinpatientswithnonischemicheartdisease
AT leonorparreira aredefibrillatorslessusefulinpatientswithnonischemicheartdisease
AT pedroamador aredefibrillatorslessusefulinpatientswithnonischemicheartdisease
AT catarinasa aredefibrillatorslessusefulinpatientswithnonischemicheartdisease
AT tatianaduarte aredefibrillatorslessusefulinpatientswithnonischemicheartdisease
AT martafonseca aredefibrillatorslessusefulinpatientswithnonischemicheartdisease
AT josefarinha aredefibrillatorslessusefulinpatientswithnonischemicheartdisease
AT claudialopes aredefibrillatorslessusefulinpatientswithnonischemicheartdisease
AT ruicaria aredefibrillatorslessusefulinpatientswithnonischemicheartdisease
_version_ 1724716379034091520
spelling doaj-59f462305fe84f96a5b8bfa066263a462020-11-25T02:55:46ZengElsevierRevista Portuguesa de Cardiologia (English Edition)2174-20492018-10-013710835841Are defibrillators less useful in patients with non-ischemic heart disease?Rita Marinheiro0Leonor Parreira1Pedro Amador2Catarina Sá3Tatiana Duarte4Marta Fonseca5José Farinha6Cláudia Lopes7Rui Caria8Corresponding author.; Serviço de Cardiologia, Hospital de São Bernardo – Centro Hospitalar de Setúbal, Setúbal, PortugalServiço de Cardiologia, Hospital de São Bernardo – Centro Hospitalar de Setúbal, Setúbal, PortugalServiço de Cardiologia, Hospital de São Bernardo – Centro Hospitalar de Setúbal, Setúbal, PortugalServiço de Cardiologia, Hospital de São Bernardo – Centro Hospitalar de Setúbal, Setúbal, PortugalServiço de Cardiologia, Hospital de São Bernardo – Centro Hospitalar de Setúbal, Setúbal, PortugalServiço de Cardiologia, Hospital de São Bernardo – Centro Hospitalar de Setúbal, Setúbal, PortugalServiço de Cardiologia, Hospital de São Bernardo – Centro Hospitalar de Setúbal, Setúbal, PortugalServiço de Cardiologia, Hospital de São Bernardo – Centro Hospitalar de Setúbal, Setúbal, PortugalServiço de Cardiologia, Hospital de São Bernardo – Centro Hospitalar de Setúbal, Setúbal, PortugalIntroduction and Objective: The benefits of implanted defibrillators in patients with ischemic heart disease (IHD) are well known. However, the evidence is less robust in patients with non-ischemic heart disease (non-IHD). We aimed to determine whether patients with non-IHD have a similar incidence of appropriate shocks and all-cause mortality compared to those with IHD. Methods: In a retrospective single-center study we analyzed all patients with implantable cardioverter-defibrillators or cardiac resynchronization therapy-defibrillators implanted for primary prevention between 2004 and 2014. The population was divided into two groups: patients with IHD and patients with non-IHD. The composite endpoint was appropriate shock and all-cause mortality. Results: Two hundred and eighty-one patients were studied, of whom 187 (66%) had IHD. Patients with IHD were older, more frequently male and with more cardiovascular risk factors. Mean follow-up was 55±42 months. Thirty-four patients (18%) with IHD and 20 patients (21%) with non-IHD had an appropriate shock (p=0.64). Eighty-nine patients (47%) with IHD and 36 (38%) with non-IHD died during follow-up (p=0.19). The rate of shocks or death over time was similar in patients with IHD and non-IHD according to Kaplan-Meier survival curve analysis (log-rank p=0.10). Conclusion: In this population, there were no differences in appropriate shocks or all-cause mortality in the two groups. Resumo: Introdução e objectivo: O benefício do desfibrilhador implantável está bem demonstrado nos doentes com cardiopatia isquémica. No entanto, a evidência deste benefício é menos robusta em doentes com cardiopatia não isquémica. Pretendeu-se determinar se os doentes com cardiopatia não isquémica apresentavam a mesma incidência de choque apropriado e mortalidade total, comparativamente àqueles com cardiopatia isquémica. Métodos: Estudo retrospetivo, em que foram analisados todos os doentes com cardioversor-desfibrilhador implantável ou terapia de ressincronização cardíaca com desfibrilhador, implantados para prevenção primária, entre 2004 a 2014, num único centro. A população foi dividida em dois grupos: doentes com cardiopatia isquémica e doentes com cardiopatia não isquémica. O endpoint primário combinado foi choque apropriado e morte por qualquer causa. Resultados: Foram estudados 281 doentes, dos quais 187 (66%) apresentavam cardiopatia isquémica. Os doentes com cardiopatia isquémica eram mais velhos, mais frequentemente do género masculino e com maior prevalência de fatores de risco cardiovasculares. O follow-up médio foi de 55±42 meses. Trinta e quatro doentes (18%) com cardiopatia isquémica e 20 doentes (21%) com cardiopatia não isquémica tiveram um choque apropriado (p=0,64). Oitenta e nove doentes (47%) com cardiopatia isquémica e 36 (38%) com cardiopatia não isquémica morreram durante o follow-up (p=0,19). A curva de Kaplan-Meier demonstra que a probabilidade de choque ou morte ao longo do tempo é semelhante nos dois grupos (logrank, p=0,14). Conclusão: Na população estudada, não existiram diferenças na probabilidade de choque apropriado ou na mortalidade total nos doentes com cardiopatia não isquémica comparativamente aqueles com cardiopatia isquémica. Keywords: Implantable defibrillator, Non-ischemic heart disease, Ischemic heart disease, Appropriate shock, Death, Palavras-chave: Cardioversor desfibrilhador implantável, Cardiopatia não isquémica, Cardiopatia isquémica, Choque apropriado, Mortehttp://www.sciencedirect.com/science/article/pii/S217420491830309X