Rapid and Specific Detection of Listeria monocytogenes With an Isothermal Amplification and Lateral Flow Strip Combined Method That Eliminates False-Positive Signals From Primer–Dimers

Listeria monocytogenes is an important foodborne pathogenic bacterium that is explicitly threatening public health and food safety. Rapid, simple, and sensitive detection methods for this pathogen are of urgent need for the increasing on-site testing demands. Application of the isothermal recombinas...

Full description

Bibliographic Details
Main Authors: Lei Wang, Panpan Zhao, Xinxin Si, Juan Li, Xiaofang Dai, Kunxiao Zhang, Song Gao, Jingquan Dong
Format: Article
Language:English
Published: Frontiers Media S.A. 2020-02-01
Series:Frontiers in Microbiology
Subjects:
Online Access:https://www.frontiersin.org/article/10.3389/fmicb.2019.02959/full
id doaj-5a8c780a35ef4449ab3f17eb32435bca
record_format Article
collection DOAJ
language English
format Article
sources DOAJ
author Lei Wang
Panpan Zhao
Xinxin Si
Juan Li
Xiaofang Dai
Kunxiao Zhang
Song Gao
Jingquan Dong
spellingShingle Lei Wang
Panpan Zhao
Xinxin Si
Juan Li
Xiaofang Dai
Kunxiao Zhang
Song Gao
Jingquan Dong
Rapid and Specific Detection of Listeria monocytogenes With an Isothermal Amplification and Lateral Flow Strip Combined Method That Eliminates False-Positive Signals From Primer–Dimers
Frontiers in Microbiology
Listeria monocytogenes
foodborne pathogen
isothermal amplification
recombinase polymerase amplification
lateral flow strip
false positive
author_facet Lei Wang
Panpan Zhao
Xinxin Si
Juan Li
Xiaofang Dai
Kunxiao Zhang
Song Gao
Jingquan Dong
author_sort Lei Wang
title Rapid and Specific Detection of Listeria monocytogenes With an Isothermal Amplification and Lateral Flow Strip Combined Method That Eliminates False-Positive Signals From Primer–Dimers
title_short Rapid and Specific Detection of Listeria monocytogenes With an Isothermal Amplification and Lateral Flow Strip Combined Method That Eliminates False-Positive Signals From Primer–Dimers
title_full Rapid and Specific Detection of Listeria monocytogenes With an Isothermal Amplification and Lateral Flow Strip Combined Method That Eliminates False-Positive Signals From Primer–Dimers
title_fullStr Rapid and Specific Detection of Listeria monocytogenes With an Isothermal Amplification and Lateral Flow Strip Combined Method That Eliminates False-Positive Signals From Primer–Dimers
title_full_unstemmed Rapid and Specific Detection of Listeria monocytogenes With an Isothermal Amplification and Lateral Flow Strip Combined Method That Eliminates False-Positive Signals From Primer–Dimers
title_sort rapid and specific detection of listeria monocytogenes with an isothermal amplification and lateral flow strip combined method that eliminates false-positive signals from primer–dimers
publisher Frontiers Media S.A.
series Frontiers in Microbiology
issn 1664-302X
publishDate 2020-02-01
description Listeria monocytogenes is an important foodborne pathogenic bacterium that is explicitly threatening public health and food safety. Rapid, simple, and sensitive detection methods for this pathogen are of urgent need for the increasing on-site testing demands. Application of the isothermal recombinase polymerase amplification (RPA) and the lateral flow strip (LFS) in the detection is promising for fast speed, high sensitivity, and little dependency on equipment and trained personnel. However, the simplicity comes with an intrinsic and non-negligible risk, the false-positive signals from primer–dimers. In this study, an improved RPA–LFS system was established for detection of L. monocytogenes that eliminated false-positive signals from primer–dimers. Primer candidates were carefully selected from the entire L. monocytogenes genome sequence and rigorously screened for specific amplifications in PCR and RPA reactions. For the optimal primer pairs, probes that matched the targeted fragment sequences, although had the smallest chance to form cross-dimers with the primers, were designed and screened. The intelligent use of the probe successfully linked the positive signal to the actual amplification product. This RPA–LFS system was highly specific to L. monocytogenes and was able to detect as low as 1 colony-forming unit of the bacterium per reaction (50 μl) without DNA purification, or 100 fg of the genomic DNA/50 μl. The amplification could be conducted under the temperature between 37 and 42°C, and the whole detection finished within 25 min. Test of artificially contaminated milk gave 100% accuracy of detection without purification of the samples. Various food samples spiked with 10 colony-forming unit of L. monocytogenes per 25 g or 25 ml were successfully detected after an enrichment time period of 6 h. The RPA–LFS system established in this study is a rapid, simple, and specific detection method for L. monocytogenes that has eliminated false-positive results from primer–dimers. In addition, this study has set a good example of eliminating the false-positive risk from primer–dimers in isothermal amplification-based detection methods, which is applicable to the development of detection technologies for other pathogens.
topic Listeria monocytogenes
foodborne pathogen
isothermal amplification
recombinase polymerase amplification
lateral flow strip
false positive
url https://www.frontiersin.org/article/10.3389/fmicb.2019.02959/full
work_keys_str_mv AT leiwang rapidandspecificdetectionoflisteriamonocytogeneswithanisothermalamplificationandlateralflowstripcombinedmethodthateliminatesfalsepositivesignalsfromprimerdimers
AT panpanzhao rapidandspecificdetectionoflisteriamonocytogeneswithanisothermalamplificationandlateralflowstripcombinedmethodthateliminatesfalsepositivesignalsfromprimerdimers
AT xinxinsi rapidandspecificdetectionoflisteriamonocytogeneswithanisothermalamplificationandlateralflowstripcombinedmethodthateliminatesfalsepositivesignalsfromprimerdimers
AT juanli rapidandspecificdetectionoflisteriamonocytogeneswithanisothermalamplificationandlateralflowstripcombinedmethodthateliminatesfalsepositivesignalsfromprimerdimers
AT xiaofangdai rapidandspecificdetectionoflisteriamonocytogeneswithanisothermalamplificationandlateralflowstripcombinedmethodthateliminatesfalsepositivesignalsfromprimerdimers
AT kunxiaozhang rapidandspecificdetectionoflisteriamonocytogeneswithanisothermalamplificationandlateralflowstripcombinedmethodthateliminatesfalsepositivesignalsfromprimerdimers
AT songgao rapidandspecificdetectionoflisteriamonocytogeneswithanisothermalamplificationandlateralflowstripcombinedmethodthateliminatesfalsepositivesignalsfromprimerdimers
AT jingquandong rapidandspecificdetectionoflisteriamonocytogeneswithanisothermalamplificationandlateralflowstripcombinedmethodthateliminatesfalsepositivesignalsfromprimerdimers
_version_ 1724695271689945088
spelling doaj-5a8c780a35ef4449ab3f17eb32435bca2020-11-25T03:01:02ZengFrontiers Media S.A.Frontiers in Microbiology1664-302X2020-02-011010.3389/fmicb.2019.02959501390Rapid and Specific Detection of Listeria monocytogenes With an Isothermal Amplification and Lateral Flow Strip Combined Method That Eliminates False-Positive Signals From Primer–DimersLei Wang0Panpan Zhao1Xinxin Si2Juan Li3Xiaofang Dai4Kunxiao Zhang5Song Gao6Jingquan Dong7Jiangsu Key Laboratory of Marine Biological Resources and Environment, Jiangsu Key Laboratory of Marine Pharmaceutical Compound Screening, Co-Innovation Center of Jiangsu Marine Bio-industry Technology, Jiangsu Ocean University, Lianyungang, ChinaCollege of Veterinary Medicine, Jilin University, Changchun, ChinaJiangsu Key Laboratory of Marine Biological Resources and Environment, Jiangsu Key Laboratory of Marine Pharmaceutical Compound Screening, Co-Innovation Center of Jiangsu Marine Bio-industry Technology, Jiangsu Ocean University, Lianyungang, ChinaWuhan Institute for Food and Cosmetic Control, Wuhan, ChinaWuhan Institute for Food and Cosmetic Control, Wuhan, ChinaJiangsu Key Laboratory of Marine Biological Resources and Environment, Jiangsu Key Laboratory of Marine Pharmaceutical Compound Screening, Co-Innovation Center of Jiangsu Marine Bio-industry Technology, Jiangsu Ocean University, Lianyungang, ChinaSchool of Pharmacy, Jiangsu Ocean University, Lianyungang, ChinaJiangsu Key Laboratory of Marine Biological Resources and Environment, Jiangsu Key Laboratory of Marine Pharmaceutical Compound Screening, Co-Innovation Center of Jiangsu Marine Bio-industry Technology, Jiangsu Ocean University, Lianyungang, ChinaListeria monocytogenes is an important foodborne pathogenic bacterium that is explicitly threatening public health and food safety. Rapid, simple, and sensitive detection methods for this pathogen are of urgent need for the increasing on-site testing demands. Application of the isothermal recombinase polymerase amplification (RPA) and the lateral flow strip (LFS) in the detection is promising for fast speed, high sensitivity, and little dependency on equipment and trained personnel. However, the simplicity comes with an intrinsic and non-negligible risk, the false-positive signals from primer–dimers. In this study, an improved RPA–LFS system was established for detection of L. monocytogenes that eliminated false-positive signals from primer–dimers. Primer candidates were carefully selected from the entire L. monocytogenes genome sequence and rigorously screened for specific amplifications in PCR and RPA reactions. For the optimal primer pairs, probes that matched the targeted fragment sequences, although had the smallest chance to form cross-dimers with the primers, were designed and screened. The intelligent use of the probe successfully linked the positive signal to the actual amplification product. This RPA–LFS system was highly specific to L. monocytogenes and was able to detect as low as 1 colony-forming unit of the bacterium per reaction (50 μl) without DNA purification, or 100 fg of the genomic DNA/50 μl. The amplification could be conducted under the temperature between 37 and 42°C, and the whole detection finished within 25 min. Test of artificially contaminated milk gave 100% accuracy of detection without purification of the samples. Various food samples spiked with 10 colony-forming unit of L. monocytogenes per 25 g or 25 ml were successfully detected after an enrichment time period of 6 h. The RPA–LFS system established in this study is a rapid, simple, and specific detection method for L. monocytogenes that has eliminated false-positive results from primer–dimers. In addition, this study has set a good example of eliminating the false-positive risk from primer–dimers in isothermal amplification-based detection methods, which is applicable to the development of detection technologies for other pathogens.https://www.frontiersin.org/article/10.3389/fmicb.2019.02959/fullListeria monocytogenesfoodborne pathogenisothermal amplificationrecombinase polymerase amplificationlateral flow stripfalse positive