Study of intraocular lens power after LASIK in myopic patients
AIM: To evaluate the differences between Haigis-L formula and CH-SRK/T when predicting intraocular lens power after laser <i>in situ</i> keratomileusis(LASIK)surgery for myopia.<p>METHODS: Seventy-two patients(140 eyes, axial length ≤26mm)after LASIK surgery were recruited between...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Press of International Journal of Ophthalmology (IJO PRESS)
2013-11-01
|
Series: | Guoji Yanke Zazhi |
Subjects: | |
Online Access: | http://www.ies.net.cn/cn_publish/2013/11/201311043.pdf |
id |
doaj-5b96d3391fc14aee89d9134c1be78175 |
---|---|
record_format |
Article |
spelling |
doaj-5b96d3391fc14aee89d9134c1be781752020-11-24T22:24:03ZengPress of International Journal of Ophthalmology (IJO PRESS)Guoji Yanke Zazhi1672-51232013-11-0113112308231010.3980/j.issn.1672-5123.2013.11.43Study of intraocular lens power after LASIK in myopic patientsChang LiuWei WangChen CaoJin-Ying LiAIM: To evaluate the differences between Haigis-L formula and CH-SRK/T when predicting intraocular lens power after laser <i>in situ</i> keratomileusis(LASIK)surgery for myopia.<p>METHODS: Seventy-two patients(140 eyes, axial length ≤26mm)after LASIK surgery were recruited between October 2012 and February 2013. Participants with other ophthalmic diseases were excluded. Haigis-L and CH-SRK/T formula were used to calculate the intraocular lens power separately after LASIK surgery and the data were analyzed using SPSS 18.0 software.<p>RESULTS: The mean value of Hoyaintraocular lens after LASIK was 22.99±1.38D by Haigis-L formula compared with 19.95±1.69D using CH-SRK/T formula. According to paired <i>t</i>-test, pairs of differential mean are -3.039±1.899D. Wilcoxon signed rank test was used and the sum of ranks was -3.408<sup>a</sup>(<i>P</i>=0.001). Meanwhile, the mean value of Allergan AR40 intraocular lens was 23.26±1.49D by Haigis-L formula; while the degree of intraocular lens calculated by CH-SRK/T formula was 20.05±1.69D. According to paired <i>t</i>-test, pairs of differential mean are -3.208±1.823D. Wilcoxon signed rank test was used and the sum of ranks was -3.408<sup>a</sup>(<i>P</i>=0.001).<p>CONCLUSION: After LASIK surgery for myopia, the degree of intraocular lens power measured by CH-SRK/T is lower than that by Haigis-L formula. The degree of intraocular lens power calculated by CH-SRK/T is more likely to be under corrected.http://www.ies.net.cn/cn_publish/2013/11/201311043.pdfHaigis-L formulaclinical history methodlaser <i>in situ</i> keratomileusisintraocular lens calculations |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Chang Liu Wei Wang Chen Cao Jin-Ying Li |
spellingShingle |
Chang Liu Wei Wang Chen Cao Jin-Ying Li Study of intraocular lens power after LASIK in myopic patients Guoji Yanke Zazhi Haigis-L formula clinical history method laser <i>in situ</i> keratomileusis intraocular lens calculations |
author_facet |
Chang Liu Wei Wang Chen Cao Jin-Ying Li |
author_sort |
Chang Liu |
title |
Study of intraocular lens power after LASIK in myopic patients |
title_short |
Study of intraocular lens power after LASIK in myopic patients |
title_full |
Study of intraocular lens power after LASIK in myopic patients |
title_fullStr |
Study of intraocular lens power after LASIK in myopic patients |
title_full_unstemmed |
Study of intraocular lens power after LASIK in myopic patients |
title_sort |
study of intraocular lens power after lasik in myopic patients |
publisher |
Press of International Journal of Ophthalmology (IJO PRESS) |
series |
Guoji Yanke Zazhi |
issn |
1672-5123 |
publishDate |
2013-11-01 |
description |
AIM: To evaluate the differences between Haigis-L formula and CH-SRK/T when predicting intraocular lens power after laser <i>in situ</i> keratomileusis(LASIK)surgery for myopia.<p>METHODS: Seventy-two patients(140 eyes, axial length ≤26mm)after LASIK surgery were recruited between October 2012 and February 2013. Participants with other ophthalmic diseases were excluded. Haigis-L and CH-SRK/T formula were used to calculate the intraocular lens power separately after LASIK surgery and the data were analyzed using SPSS 18.0 software.<p>RESULTS: The mean value of Hoyaintraocular lens after LASIK was 22.99±1.38D by Haigis-L formula compared with 19.95±1.69D using CH-SRK/T formula. According to paired <i>t</i>-test, pairs of differential mean are -3.039±1.899D. Wilcoxon signed rank test was used and the sum of ranks was -3.408<sup>a</sup>(<i>P</i>=0.001). Meanwhile, the mean value of Allergan AR40 intraocular lens was 23.26±1.49D by Haigis-L formula; while the degree of intraocular lens calculated by CH-SRK/T formula was 20.05±1.69D. According to paired <i>t</i>-test, pairs of differential mean are -3.208±1.823D. Wilcoxon signed rank test was used and the sum of ranks was -3.408<sup>a</sup>(<i>P</i>=0.001).<p>CONCLUSION: After LASIK surgery for myopia, the degree of intraocular lens power measured by CH-SRK/T is lower than that by Haigis-L formula. The degree of intraocular lens power calculated by CH-SRK/T is more likely to be under corrected. |
topic |
Haigis-L formula clinical history method laser <i>in situ</i> keratomileusis intraocular lens calculations |
url |
http://www.ies.net.cn/cn_publish/2013/11/201311043.pdf |
work_keys_str_mv |
AT changliu studyofintraocularlenspowerafterlasikinmyopicpatients AT weiwang studyofintraocularlenspowerafterlasikinmyopicpatients AT chencao studyofintraocularlenspowerafterlasikinmyopicpatients AT jinyingli studyofintraocularlenspowerafterlasikinmyopicpatients |
_version_ |
1725762556336799744 |