Multielemental composition of some Slovenian coals determined with k0 -INAA method and comparison with ICP-MS method

In this multi-elemental study, 34 elements (Ag, As, Au, Ba, Br, Ca, Cd, Ce, Co, Cr, Cs, Eu, Fe, Ga, Hg, Hf, K, La, Mo, Na, Nd, Rb, Sb, Sc, Se, Sm, Sr, Ta, Tb, Th, U, Yb, Zn and Zr) were analysed in Slovenian coals from operative (Velenje) and non-operative (Kanižarica and Senovo) coal mines and an...

Full description

Bibliographic Details
Main Authors: Tjaša Kanduč, Timotej Verbovšek, Rok Novak, Radojko Jaćimović
Format: Article
Language:English
Published: Geological Survey of Slovenia 2019-12-01
Series:Geologija
Subjects:
Online Access:http://www.geologija-revija.si/dokument.aspx?id=1363
id doaj-5bce505b37f843bbb6aa8d10e6e66504
record_format Article
spelling doaj-5bce505b37f843bbb6aa8d10e6e665042021-07-02T07:53:58ZengGeological Survey of SloveniaGeologija0016-77891854-620X2019-12-0162221923610.5474/geologija.2019.010Multielemental composition of some Slovenian coals determined with k0 -INAA method and comparison with ICP-MS methodTjaša KandučTimotej VerbovšekRok NovakRadojko JaćimovićIn this multi-elemental study, 34 elements (Ag, As, Au, Ba, Br, Ca, Cd, Ce, Co, Cr, Cs, Eu, Fe, Ga, Hg, Hf, K, La, Mo, Na, Nd, Rb, Sb, Sc, Se, Sm, Sr, Ta, Tb, Th, U, Yb, Zn and Zr) were analysed in Slovenian coals from operative (Velenje) and non-operative (Kanižarica and Senovo) coal mines and an imported Indonesia coal using k0-Instrumental Neutron Activation Analysis (k0-INAA) and compared to inductively coupled plasma-mass spectroscopy (ICP-MS). Weaker regressions between both methods ICP-MS and k0-INAA are obtained for following elements: Cs, Co, Eu, Se, Sm and Tb with low concentration (below 1 mg/kg). The k0-INAA data are comparable to the ICP-MS data for the majority of elements. The levels of major elements measured with k0-INAA are as follows: Ca>Fe>K>Na>Sr>Ba. Minor and trace elements, as well as rare earth elements (REEs), are comparable with coal values worldwide. Data of trace elements in coal are important since they are related to air emissions. According to our data obtained with both methods (ICP-MS and k0-INAA) we can conclude that concentrations of trace elements, which impact to human health and are combusted (Indonesian and Velenje coal) in Slovenia are comparable to world averages coal. http://www.geologija-revija.si/dokument.aspx?id=1363k0-instrumental neutron activation analysis (k0-inaa)multielemental compositioncoalpca analysisslovenia
collection DOAJ
language English
format Article
sources DOAJ
author Tjaša Kanduč
Timotej Verbovšek
Rok Novak
Radojko Jaćimović
spellingShingle Tjaša Kanduč
Timotej Verbovšek
Rok Novak
Radojko Jaćimović
Multielemental composition of some Slovenian coals determined with k0 -INAA method and comparison with ICP-MS method
Geologija
k0-instrumental neutron activation analysis (k0-inaa)
multielemental composition
coal
pca analysis
slovenia
author_facet Tjaša Kanduč
Timotej Verbovšek
Rok Novak
Radojko Jaćimović
author_sort Tjaša Kanduč
title Multielemental composition of some Slovenian coals determined with k0 -INAA method and comparison with ICP-MS method
title_short Multielemental composition of some Slovenian coals determined with k0 -INAA method and comparison with ICP-MS method
title_full Multielemental composition of some Slovenian coals determined with k0 -INAA method and comparison with ICP-MS method
title_fullStr Multielemental composition of some Slovenian coals determined with k0 -INAA method and comparison with ICP-MS method
title_full_unstemmed Multielemental composition of some Slovenian coals determined with k0 -INAA method and comparison with ICP-MS method
title_sort multielemental composition of some slovenian coals determined with k0 -inaa method and comparison with icp-ms method
publisher Geological Survey of Slovenia
series Geologija
issn 0016-7789
1854-620X
publishDate 2019-12-01
description In this multi-elemental study, 34 elements (Ag, As, Au, Ba, Br, Ca, Cd, Ce, Co, Cr, Cs, Eu, Fe, Ga, Hg, Hf, K, La, Mo, Na, Nd, Rb, Sb, Sc, Se, Sm, Sr, Ta, Tb, Th, U, Yb, Zn and Zr) were analysed in Slovenian coals from operative (Velenje) and non-operative (Kanižarica and Senovo) coal mines and an imported Indonesia coal using k0-Instrumental Neutron Activation Analysis (k0-INAA) and compared to inductively coupled plasma-mass spectroscopy (ICP-MS). Weaker regressions between both methods ICP-MS and k0-INAA are obtained for following elements: Cs, Co, Eu, Se, Sm and Tb with low concentration (below 1 mg/kg). The k0-INAA data are comparable to the ICP-MS data for the majority of elements. The levels of major elements measured with k0-INAA are as follows: Ca>Fe>K>Na>Sr>Ba. Minor and trace elements, as well as rare earth elements (REEs), are comparable with coal values worldwide. Data of trace elements in coal are important since they are related to air emissions. According to our data obtained with both methods (ICP-MS and k0-INAA) we can conclude that concentrations of trace elements, which impact to human health and are combusted (Indonesian and Velenje coal) in Slovenia are comparable to world averages coal.
topic k0-instrumental neutron activation analysis (k0-inaa)
multielemental composition
coal
pca analysis
slovenia
url http://www.geologija-revija.si/dokument.aspx?id=1363
work_keys_str_mv AT tjasakanduc multielementalcompositionofsomesloveniancoalsdeterminedwithk0inaamethodandcomparisonwithicpmsmethod
AT timotejverbovsek multielementalcompositionofsomesloveniancoalsdeterminedwithk0inaamethodandcomparisonwithicpmsmethod
AT roknovak multielementalcompositionofsomesloveniancoalsdeterminedwithk0inaamethodandcomparisonwithicpmsmethod
AT radojkojacimovic multielementalcompositionofsomesloveniancoalsdeterminedwithk0inaamethodandcomparisonwithicpmsmethod
_version_ 1721335479164469248