Simulation and Comparison of Twenty Five Level Diode Clamped & Cascaded H-Bridge Multilevel Inverter

This paper presents the comparative study of three phase twenty five level diode clamped and cascaded H-bridge multilevel inverters. The comparison is made in respect of requirement of devices, quality of output voltage and reduction of total harmonic distortion at the multilevel inverter terminals....

Full description

Bibliographic Details
Main Authors: S. R. Sadu, P. V. Prasad, G. N. Srinivas
Format: Article
Language:English
Published: Iran University of Science and Technology 2018-03-01
Series:Iranian Journal of Electrical and Electronic Engineering
Subjects:
Online Access:http://ijeee.iust.ac.ir/browse.php?a_code=A-10-2444-1&slc_lang=en&sid=1
id doaj-5f28b0c654ce4e86b3780b55f599c455
record_format Article
spelling doaj-5f28b0c654ce4e86b3780b55f599c4552020-11-25T01:28:25ZengIran University of Science and TechnologyIranian Journal of Electrical and Electronic Engineering1735-28272383-38902018-03-0114195105Simulation and Comparison of Twenty Five Level Diode Clamped & Cascaded H-Bridge Multilevel InverterS. R. Sadu0P. V. Prasad1G. N. Srinivas2 EEE Department, GNITC, Ibrahimpatnam, Hyderabad, India. EEE Department, CBIT, Gandipet, Hyderabad, India. EEE Department, JNTUH, Hyderabad, India. This paper presents the comparative study of three phase twenty five level diode clamped and cascaded H-bridge multilevel inverters. The comparison is made in respect of requirement of devices, quality of output voltage and reduction of total harmonic distortion at the multilevel inverter terminals. In this work multicarrier sinusoidal pulse modulation control methods of Phase disposition (PD-PWM), phase opposition disposition (POD-PWM) and Alternative Phase Opposition Disposition (APOD-PWM) pulse width modulation control strategies are applied for both diode clamped and cascaded H-bridge multilevel inverters and compared its total harmonic distortion. The performance of both diode and cascaded H-bridge multilevel inverters is investigated and compared. Based on simulation results it is observed that the output voltage of the cascaded H-bridge multilevel inverters is better as compared to the diode clamped multilevel inverter. The proposed multilevel inverters are simulated using MATLAB/Simulink software.http://ijeee.iust.ac.ir/browse.php?a_code=A-10-2444-1&slc_lang=en&sid=1Diode Clamped Type Multilevel Inverter Cascaded H-Bridge Multilevel Inverter Phase Disposition Pulse Width Modulation (PD-PWM) Phase Opposition Disposition Pulse Width Modulation (POD-PWM) Alternative Phase Opposition Disposition Pulse Width Modulatio
collection DOAJ
language English
format Article
sources DOAJ
author S. R. Sadu
P. V. Prasad
G. N. Srinivas
spellingShingle S. R. Sadu
P. V. Prasad
G. N. Srinivas
Simulation and Comparison of Twenty Five Level Diode Clamped & Cascaded H-Bridge Multilevel Inverter
Iranian Journal of Electrical and Electronic Engineering
Diode Clamped Type Multilevel Inverter
Cascaded H-Bridge Multilevel Inverter
Phase Disposition Pulse Width Modulation (PD-PWM)
Phase Opposition Disposition Pulse Width Modulation (POD-PWM)
Alternative Phase Opposition Disposition Pulse Width Modulatio
author_facet S. R. Sadu
P. V. Prasad
G. N. Srinivas
author_sort S. R. Sadu
title Simulation and Comparison of Twenty Five Level Diode Clamped & Cascaded H-Bridge Multilevel Inverter
title_short Simulation and Comparison of Twenty Five Level Diode Clamped & Cascaded H-Bridge Multilevel Inverter
title_full Simulation and Comparison of Twenty Five Level Diode Clamped & Cascaded H-Bridge Multilevel Inverter
title_fullStr Simulation and Comparison of Twenty Five Level Diode Clamped & Cascaded H-Bridge Multilevel Inverter
title_full_unstemmed Simulation and Comparison of Twenty Five Level Diode Clamped & Cascaded H-Bridge Multilevel Inverter
title_sort simulation and comparison of twenty five level diode clamped & cascaded h-bridge multilevel inverter
publisher Iran University of Science and Technology
series Iranian Journal of Electrical and Electronic Engineering
issn 1735-2827
2383-3890
publishDate 2018-03-01
description This paper presents the comparative study of three phase twenty five level diode clamped and cascaded H-bridge multilevel inverters. The comparison is made in respect of requirement of devices, quality of output voltage and reduction of total harmonic distortion at the multilevel inverter terminals. In this work multicarrier sinusoidal pulse modulation control methods of Phase disposition (PD-PWM), phase opposition disposition (POD-PWM) and Alternative Phase Opposition Disposition (APOD-PWM) pulse width modulation control strategies are applied for both diode clamped and cascaded H-bridge multilevel inverters and compared its total harmonic distortion. The performance of both diode and cascaded H-bridge multilevel inverters is investigated and compared. Based on simulation results it is observed that the output voltage of the cascaded H-bridge multilevel inverters is better as compared to the diode clamped multilevel inverter. The proposed multilevel inverters are simulated using MATLAB/Simulink software.
topic Diode Clamped Type Multilevel Inverter
Cascaded H-Bridge Multilevel Inverter
Phase Disposition Pulse Width Modulation (PD-PWM)
Phase Opposition Disposition Pulse Width Modulation (POD-PWM)
Alternative Phase Opposition Disposition Pulse Width Modulatio
url http://ijeee.iust.ac.ir/browse.php?a_code=A-10-2444-1&slc_lang=en&sid=1
work_keys_str_mv AT srsadu simulationandcomparisonoftwentyfiveleveldiodeclampedcascadedhbridgemultilevelinverter
AT pvprasad simulationandcomparisonoftwentyfiveleveldiodeclampedcascadedhbridgemultilevelinverter
AT gnsrinivas simulationandcomparisonoftwentyfiveleveldiodeclampedcascadedhbridgemultilevelinverter
_version_ 1725101937405198336