Bone density: comparative evaluation of Hounsfield units in multislice and cone-beam computed tomography

The aim of this study was to evaluate the validity of the bone density value of potential implant sites in HU obtained by a specific cone-beam computed tomography (CBCT) device. In this study, the HU values obtained using a MSCT scanner were used as the gold standard. Twenty mandibles (40 potential...

Full description

Bibliographic Details
Main Authors: Isabela Maria de Carvalho Crusoé Silva, Deborah Queiroz de Freitas, Glaucia Maria Bovi Ambrosano, Frab Norberto Bóscolo, Solange Maria Almeida
Format: Article
Language:English
Published: Sociedade Brasileira de Pesquisa Odontológica 2012-12-01
Series:Brazilian Oral Research
Subjects:
Online Access:http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242012000600011
id doaj-5f7fddc7a326429ab73830fbe53f6da4
record_format Article
spelling doaj-5f7fddc7a326429ab73830fbe53f6da42020-11-25T02:50:07ZengSociedade Brasileira de Pesquisa Odontológica Brazilian Oral Research1806-83242012-12-0126655055610.1590/S1806-83242012000600011Bone density: comparative evaluation of Hounsfield units in multislice and cone-beam computed tomographyIsabela Maria de Carvalho Crusoé SilvaDeborah Queiroz de FreitasGlaucia Maria Bovi AmbrosanoFrab Norberto BóscoloSolange Maria AlmeidaThe aim of this study was to evaluate the validity of the bone density value of potential implant sites in HU obtained by a specific cone-beam computed tomography (CBCT) device. In this study, the HU values obtained using a MSCT scanner were used as the gold standard. Twenty mandibles (40 potential implant sites) were scanned using an MSCT scanner (Somatom Sensation 40) and a CBCT scanner (i-CAT). The MSCT images were evaluated using the Syngo CT Workplace software and the CBCT images, using the XoranCat software. The images were evaluated twice by three oral radiologists, at 60 day intervals. The trabecular bone density of the same area was evaluated on both images. Intraclass coefficients (ICC) were calculated to examine the agreement between the examiners and between the two periods of evaluation. The bone density and area of the ROI were compared by the Student t test and Bland-Altman analysis. ICCs were excellent. The mean HU value obtained using CBCT (418.06) was higher than that obtained using MSCT (313.13), with a statistically significant difference (p < 0.0001). In addition, Bland-Altman analysis showed that the HU measures were not equivalent. In conclusion, the bone density in HU with CBCT images obtained using the device studied proved unreliable, since it was higher than that obtained using MSCT.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242012000600011TomographyX-Ray ComputedCone-Beam Computed TomographyBone DensityDental Implants
collection DOAJ
language English
format Article
sources DOAJ
author Isabela Maria de Carvalho Crusoé Silva
Deborah Queiroz de Freitas
Glaucia Maria Bovi Ambrosano
Frab Norberto Bóscolo
Solange Maria Almeida
spellingShingle Isabela Maria de Carvalho Crusoé Silva
Deborah Queiroz de Freitas
Glaucia Maria Bovi Ambrosano
Frab Norberto Bóscolo
Solange Maria Almeida
Bone density: comparative evaluation of Hounsfield units in multislice and cone-beam computed tomography
Brazilian Oral Research
Tomography
X-Ray Computed
Cone-Beam Computed Tomography
Bone Density
Dental Implants
author_facet Isabela Maria de Carvalho Crusoé Silva
Deborah Queiroz de Freitas
Glaucia Maria Bovi Ambrosano
Frab Norberto Bóscolo
Solange Maria Almeida
author_sort Isabela Maria de Carvalho Crusoé Silva
title Bone density: comparative evaluation of Hounsfield units in multislice and cone-beam computed tomography
title_short Bone density: comparative evaluation of Hounsfield units in multislice and cone-beam computed tomography
title_full Bone density: comparative evaluation of Hounsfield units in multislice and cone-beam computed tomography
title_fullStr Bone density: comparative evaluation of Hounsfield units in multislice and cone-beam computed tomography
title_full_unstemmed Bone density: comparative evaluation of Hounsfield units in multislice and cone-beam computed tomography
title_sort bone density: comparative evaluation of hounsfield units in multislice and cone-beam computed tomography
publisher Sociedade Brasileira de Pesquisa Odontológica
series Brazilian Oral Research
issn 1806-8324
publishDate 2012-12-01
description The aim of this study was to evaluate the validity of the bone density value of potential implant sites in HU obtained by a specific cone-beam computed tomography (CBCT) device. In this study, the HU values obtained using a MSCT scanner were used as the gold standard. Twenty mandibles (40 potential implant sites) were scanned using an MSCT scanner (Somatom Sensation 40) and a CBCT scanner (i-CAT). The MSCT images were evaluated using the Syngo CT Workplace software and the CBCT images, using the XoranCat software. The images were evaluated twice by three oral radiologists, at 60 day intervals. The trabecular bone density of the same area was evaluated on both images. Intraclass coefficients (ICC) were calculated to examine the agreement between the examiners and between the two periods of evaluation. The bone density and area of the ROI were compared by the Student t test and Bland-Altman analysis. ICCs were excellent. The mean HU value obtained using CBCT (418.06) was higher than that obtained using MSCT (313.13), with a statistically significant difference (p < 0.0001). In addition, Bland-Altman analysis showed that the HU measures were not equivalent. In conclusion, the bone density in HU with CBCT images obtained using the device studied proved unreliable, since it was higher than that obtained using MSCT.
topic Tomography
X-Ray Computed
Cone-Beam Computed Tomography
Bone Density
Dental Implants
url http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242012000600011
work_keys_str_mv AT isabelamariadecarvalhocrusoesilva bonedensitycomparativeevaluationofhounsfieldunitsinmultisliceandconebeamcomputedtomography
AT deborahqueirozdefreitas bonedensitycomparativeevaluationofhounsfieldunitsinmultisliceandconebeamcomputedtomography
AT glauciamariaboviambrosano bonedensitycomparativeevaluationofhounsfieldunitsinmultisliceandconebeamcomputedtomography
AT frabnorbertoboscolo bonedensitycomparativeevaluationofhounsfieldunitsinmultisliceandconebeamcomputedtomography
AT solangemariaalmeida bonedensitycomparativeevaluationofhounsfieldunitsinmultisliceandconebeamcomputedtomography
_version_ 1724740074065625088