Pulmonary Nodule Detection in Patients with a Primary Malignancy Using Hybrid PET/MRI: Is There Value in Adding Contrast-Enhanced MR Imaging?

To investigate the added value of post-contrast VIBE (volumetric-interpolated breath-hold examination) to PET/MR imaging for pulmonary nodule detection in patients with primary malignancies.This retrospective institutional review board-approved study, with waiver of informed consent, included 51 con...

Full description

Bibliographic Details
Main Authors: Kyung Hee Lee, Chang Min Park, Sang Min Lee, Jeong Min Lee, Jeong Yeon Cho, Jin Chul Paeng, Su Yeon Ahn, Jin Mo Goo
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2015-01-01
Series:PLoS ONE
Online Access:http://europepmc.org/articles/PMC4465933?pdf=render
Description
Summary:To investigate the added value of post-contrast VIBE (volumetric-interpolated breath-hold examination) to PET/MR imaging for pulmonary nodule detection in patients with primary malignancies.This retrospective institutional review board-approved study, with waiver of informed consent, included 51 consecutive patients who underwent 18F-fluorodeoxyglucose (FDG) PET/MR followed by PET/CT for cancer staging. In all patients, the thorax was examined with pre-and post-contrast VIBE MR with simultaneous PET acquisition. Two readers blinded to the patients' data independently recorded their level of suspicion for pulmonary nodules based on PET, pre-contrast VIBE, and fused PET/MR images (first session), and reassessed them 4-weeks later after addition of post-contrast VIBE (second session). Jackknife alternative free-response receiver-operating-characteristic (JAFROC) analysis was performed, with PET/CT as the reference standard.A total of 151 pulmonary nodules (44 FDG-avid, 107 non-FDG-avid nodules) were detected on PET/CT, including 62 nodules≥5 mm in diameter and 89 nodules<5 mm. In the first session, the average nodule detection rate was 53.3% for all nodules, 97.7% for FDG-avid, 35.0% for non-FDG-avid nodules, 87.9% for nodules≥5 mm and 29.2% for nodules<5 mm. In the second session, the average detection rate was 53.3% for all nodules, 97.7% for FDG-avid, 35.0% for non-FDG-avid nodules, 85.5% for nodules≥5 mm and 30.9% for nodules<5 mm. The average JAFROC figure-of-merit was 0.837 in the first session and 0.848 in the second session. There were no significant differences in detection performance between sessions (P=0.48).The addition of post-contrast VIBE to hybrid PET/MR imaging provided no additional value in the detection of pulmonary nodules.
ISSN:1932-6203