Unified Bayesian Estimator of EEG Reference at Infinity: rREST (Regularized Reference Electrode Standardization Technique)

The choice of reference for the electroencephalogram (EEG) is a long-lasting unsolved issue resulting in inconsistent usages and endless debates. Currently, both the average reference (AR) and the reference electrode standardization technique (REST) are two primary, apparently irreconcilable contend...

Full description

Bibliographic Details
Main Authors: Shiang Hu, Dezhong Yao, Pedro A. Valdes-Sosa
Format: Article
Language:English
Published: Frontiers Media S.A. 2018-05-01
Series:Frontiers in Neuroscience
Subjects:
Online Access:http://journal.frontiersin.org/article/10.3389/fnins.2018.00297/full
id doaj-603a676f0b3a4bb3b06d2104456c8d5b
record_format Article
spelling doaj-603a676f0b3a4bb3b06d2104456c8d5b2020-11-25T02:19:35ZengFrontiers Media S.A.Frontiers in Neuroscience1662-453X2018-05-011210.3389/fnins.2018.00297344688Unified Bayesian Estimator of EEG Reference at Infinity: rREST (Regularized Reference Electrode Standardization Technique)Shiang Hu0Dezhong Yao1Pedro A. Valdes-Sosa2Pedro A. Valdes-Sosa3The Clinical Hospital of Chengdu Brain Science Institute, MOE Key Lab for NeuroInformation, University of Electronic Science and Technology of China, Chengdu, ChinaThe Clinical Hospital of Chengdu Brain Science Institute, MOE Key Lab for NeuroInformation, University of Electronic Science and Technology of China, Chengdu, ChinaThe Clinical Hospital of Chengdu Brain Science Institute, MOE Key Lab for NeuroInformation, University of Electronic Science and Technology of China, Chengdu, ChinaCuban Neuroscience Center, Havana, CubaThe choice of reference for the electroencephalogram (EEG) is a long-lasting unsolved issue resulting in inconsistent usages and endless debates. Currently, both the average reference (AR) and the reference electrode standardization technique (REST) are two primary, apparently irreconcilable contenders. We propose a theoretical framework to resolve this reference issue by formulating both (a) estimation of potentials at infinity, and (b) determination of the reference, as a unified Bayesian linear inverse problem, which can be solved by maximum a posterior estimation. We find that AR and REST are very particular cases of this unified framework: AR results from biophysically non-informative prior; while REST utilizes the prior based on the EEG generative model. To allow for simultaneous denoising and reference estimation, we develop the regularized versions of AR and REST, named rAR and rREST, respectively. Both depend on a regularization parameter that is the noise to signal variance ratio. Traditional and new estimators are evaluated with this framework, by both simulations and analysis of real resting EEGs. Toward this end, we leverage the MRI and EEG data from 89 subjects which participated in the Cuban Human Brain Mapping Project. Generated artificial EEGs—with a known ground truth, show that relative error in estimating the EEG potentials at infinity is lowest for rREST. It also reveals that realistic volume conductor models improve the performances of REST and rREST. Importantly, for practical applications, it is shown that an average lead field gives the results comparable to the individual lead field. Finally, it is shown that the selection of the regularization parameter with Generalized Cross-Validation (GCV) is close to the “oracle” choice based on the ground truth. When evaluated with the real 89 resting state EEGs, rREST consistently yields the lowest GCV. This study provides a novel perspective to the EEG reference problem by means of a unified inverse solution framework. It may allow additional principled theoretical formulations and numerical evaluation of performance.http://journal.frontiersin.org/article/10.3389/fnins.2018.00297/fullEEG referenceunified estimatorregularizationinverse problemvolume conductionrelative error
collection DOAJ
language English
format Article
sources DOAJ
author Shiang Hu
Dezhong Yao
Pedro A. Valdes-Sosa
Pedro A. Valdes-Sosa
spellingShingle Shiang Hu
Dezhong Yao
Pedro A. Valdes-Sosa
Pedro A. Valdes-Sosa
Unified Bayesian Estimator of EEG Reference at Infinity: rREST (Regularized Reference Electrode Standardization Technique)
Frontiers in Neuroscience
EEG reference
unified estimator
regularization
inverse problem
volume conduction
relative error
author_facet Shiang Hu
Dezhong Yao
Pedro A. Valdes-Sosa
Pedro A. Valdes-Sosa
author_sort Shiang Hu
title Unified Bayesian Estimator of EEG Reference at Infinity: rREST (Regularized Reference Electrode Standardization Technique)
title_short Unified Bayesian Estimator of EEG Reference at Infinity: rREST (Regularized Reference Electrode Standardization Technique)
title_full Unified Bayesian Estimator of EEG Reference at Infinity: rREST (Regularized Reference Electrode Standardization Technique)
title_fullStr Unified Bayesian Estimator of EEG Reference at Infinity: rREST (Regularized Reference Electrode Standardization Technique)
title_full_unstemmed Unified Bayesian Estimator of EEG Reference at Infinity: rREST (Regularized Reference Electrode Standardization Technique)
title_sort unified bayesian estimator of eeg reference at infinity: rrest (regularized reference electrode standardization technique)
publisher Frontiers Media S.A.
series Frontiers in Neuroscience
issn 1662-453X
publishDate 2018-05-01
description The choice of reference for the electroencephalogram (EEG) is a long-lasting unsolved issue resulting in inconsistent usages and endless debates. Currently, both the average reference (AR) and the reference electrode standardization technique (REST) are two primary, apparently irreconcilable contenders. We propose a theoretical framework to resolve this reference issue by formulating both (a) estimation of potentials at infinity, and (b) determination of the reference, as a unified Bayesian linear inverse problem, which can be solved by maximum a posterior estimation. We find that AR and REST are very particular cases of this unified framework: AR results from biophysically non-informative prior; while REST utilizes the prior based on the EEG generative model. To allow for simultaneous denoising and reference estimation, we develop the regularized versions of AR and REST, named rAR and rREST, respectively. Both depend on a regularization parameter that is the noise to signal variance ratio. Traditional and new estimators are evaluated with this framework, by both simulations and analysis of real resting EEGs. Toward this end, we leverage the MRI and EEG data from 89 subjects which participated in the Cuban Human Brain Mapping Project. Generated artificial EEGs—with a known ground truth, show that relative error in estimating the EEG potentials at infinity is lowest for rREST. It also reveals that realistic volume conductor models improve the performances of REST and rREST. Importantly, for practical applications, it is shown that an average lead field gives the results comparable to the individual lead field. Finally, it is shown that the selection of the regularization parameter with Generalized Cross-Validation (GCV) is close to the “oracle” choice based on the ground truth. When evaluated with the real 89 resting state EEGs, rREST consistently yields the lowest GCV. This study provides a novel perspective to the EEG reference problem by means of a unified inverse solution framework. It may allow additional principled theoretical formulations and numerical evaluation of performance.
topic EEG reference
unified estimator
regularization
inverse problem
volume conduction
relative error
url http://journal.frontiersin.org/article/10.3389/fnins.2018.00297/full
work_keys_str_mv AT shianghu unifiedbayesianestimatorofeegreferenceatinfinityrrestregularizedreferenceelectrodestandardizationtechnique
AT dezhongyao unifiedbayesianestimatorofeegreferenceatinfinityrrestregularizedreferenceelectrodestandardizationtechnique
AT pedroavaldessosa unifiedbayesianestimatorofeegreferenceatinfinityrrestregularizedreferenceelectrodestandardizationtechnique
AT pedroavaldessosa unifiedbayesianestimatorofeegreferenceatinfinityrrestregularizedreferenceelectrodestandardizationtechnique
_version_ 1724875694064795648