Unified Bayesian Estimator of EEG Reference at Infinity: rREST (Regularized Reference Electrode Standardization Technique)
The choice of reference for the electroencephalogram (EEG) is a long-lasting unsolved issue resulting in inconsistent usages and endless debates. Currently, both the average reference (AR) and the reference electrode standardization technique (REST) are two primary, apparently irreconcilable contend...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Frontiers Media S.A.
2018-05-01
|
Series: | Frontiers in Neuroscience |
Subjects: | |
Online Access: | http://journal.frontiersin.org/article/10.3389/fnins.2018.00297/full |
id |
doaj-603a676f0b3a4bb3b06d2104456c8d5b |
---|---|
record_format |
Article |
spelling |
doaj-603a676f0b3a4bb3b06d2104456c8d5b2020-11-25T02:19:35ZengFrontiers Media S.A.Frontiers in Neuroscience1662-453X2018-05-011210.3389/fnins.2018.00297344688Unified Bayesian Estimator of EEG Reference at Infinity: rREST (Regularized Reference Electrode Standardization Technique)Shiang Hu0Dezhong Yao1Pedro A. Valdes-Sosa2Pedro A. Valdes-Sosa3The Clinical Hospital of Chengdu Brain Science Institute, MOE Key Lab for NeuroInformation, University of Electronic Science and Technology of China, Chengdu, ChinaThe Clinical Hospital of Chengdu Brain Science Institute, MOE Key Lab for NeuroInformation, University of Electronic Science and Technology of China, Chengdu, ChinaThe Clinical Hospital of Chengdu Brain Science Institute, MOE Key Lab for NeuroInformation, University of Electronic Science and Technology of China, Chengdu, ChinaCuban Neuroscience Center, Havana, CubaThe choice of reference for the electroencephalogram (EEG) is a long-lasting unsolved issue resulting in inconsistent usages and endless debates. Currently, both the average reference (AR) and the reference electrode standardization technique (REST) are two primary, apparently irreconcilable contenders. We propose a theoretical framework to resolve this reference issue by formulating both (a) estimation of potentials at infinity, and (b) determination of the reference, as a unified Bayesian linear inverse problem, which can be solved by maximum a posterior estimation. We find that AR and REST are very particular cases of this unified framework: AR results from biophysically non-informative prior; while REST utilizes the prior based on the EEG generative model. To allow for simultaneous denoising and reference estimation, we develop the regularized versions of AR and REST, named rAR and rREST, respectively. Both depend on a regularization parameter that is the noise to signal variance ratio. Traditional and new estimators are evaluated with this framework, by both simulations and analysis of real resting EEGs. Toward this end, we leverage the MRI and EEG data from 89 subjects which participated in the Cuban Human Brain Mapping Project. Generated artificial EEGs—with a known ground truth, show that relative error in estimating the EEG potentials at infinity is lowest for rREST. It also reveals that realistic volume conductor models improve the performances of REST and rREST. Importantly, for practical applications, it is shown that an average lead field gives the results comparable to the individual lead field. Finally, it is shown that the selection of the regularization parameter with Generalized Cross-Validation (GCV) is close to the “oracle” choice based on the ground truth. When evaluated with the real 89 resting state EEGs, rREST consistently yields the lowest GCV. This study provides a novel perspective to the EEG reference problem by means of a unified inverse solution framework. It may allow additional principled theoretical formulations and numerical evaluation of performance.http://journal.frontiersin.org/article/10.3389/fnins.2018.00297/fullEEG referenceunified estimatorregularizationinverse problemvolume conductionrelative error |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Shiang Hu Dezhong Yao Pedro A. Valdes-Sosa Pedro A. Valdes-Sosa |
spellingShingle |
Shiang Hu Dezhong Yao Pedro A. Valdes-Sosa Pedro A. Valdes-Sosa Unified Bayesian Estimator of EEG Reference at Infinity: rREST (Regularized Reference Electrode Standardization Technique) Frontiers in Neuroscience EEG reference unified estimator regularization inverse problem volume conduction relative error |
author_facet |
Shiang Hu Dezhong Yao Pedro A. Valdes-Sosa Pedro A. Valdes-Sosa |
author_sort |
Shiang Hu |
title |
Unified Bayesian Estimator of EEG Reference at Infinity: rREST (Regularized Reference Electrode Standardization Technique) |
title_short |
Unified Bayesian Estimator of EEG Reference at Infinity: rREST (Regularized Reference Electrode Standardization Technique) |
title_full |
Unified Bayesian Estimator of EEG Reference at Infinity: rREST (Regularized Reference Electrode Standardization Technique) |
title_fullStr |
Unified Bayesian Estimator of EEG Reference at Infinity: rREST (Regularized Reference Electrode Standardization Technique) |
title_full_unstemmed |
Unified Bayesian Estimator of EEG Reference at Infinity: rREST (Regularized Reference Electrode Standardization Technique) |
title_sort |
unified bayesian estimator of eeg reference at infinity: rrest (regularized reference electrode standardization technique) |
publisher |
Frontiers Media S.A. |
series |
Frontiers in Neuroscience |
issn |
1662-453X |
publishDate |
2018-05-01 |
description |
The choice of reference for the electroencephalogram (EEG) is a long-lasting unsolved issue resulting in inconsistent usages and endless debates. Currently, both the average reference (AR) and the reference electrode standardization technique (REST) are two primary, apparently irreconcilable contenders. We propose a theoretical framework to resolve this reference issue by formulating both (a) estimation of potentials at infinity, and (b) determination of the reference, as a unified Bayesian linear inverse problem, which can be solved by maximum a posterior estimation. We find that AR and REST are very particular cases of this unified framework: AR results from biophysically non-informative prior; while REST utilizes the prior based on the EEG generative model. To allow for simultaneous denoising and reference estimation, we develop the regularized versions of AR and REST, named rAR and rREST, respectively. Both depend on a regularization parameter that is the noise to signal variance ratio. Traditional and new estimators are evaluated with this framework, by both simulations and analysis of real resting EEGs. Toward this end, we leverage the MRI and EEG data from 89 subjects which participated in the Cuban Human Brain Mapping Project. Generated artificial EEGs—with a known ground truth, show that relative error in estimating the EEG potentials at infinity is lowest for rREST. It also reveals that realistic volume conductor models improve the performances of REST and rREST. Importantly, for practical applications, it is shown that an average lead field gives the results comparable to the individual lead field. Finally, it is shown that the selection of the regularization parameter with Generalized Cross-Validation (GCV) is close to the “oracle” choice based on the ground truth. When evaluated with the real 89 resting state EEGs, rREST consistently yields the lowest GCV. This study provides a novel perspective to the EEG reference problem by means of a unified inverse solution framework. It may allow additional principled theoretical formulations and numerical evaluation of performance. |
topic |
EEG reference unified estimator regularization inverse problem volume conduction relative error |
url |
http://journal.frontiersin.org/article/10.3389/fnins.2018.00297/full |
work_keys_str_mv |
AT shianghu unifiedbayesianestimatorofeegreferenceatinfinityrrestregularizedreferenceelectrodestandardizationtechnique AT dezhongyao unifiedbayesianestimatorofeegreferenceatinfinityrrestregularizedreferenceelectrodestandardizationtechnique AT pedroavaldessosa unifiedbayesianestimatorofeegreferenceatinfinityrrestregularizedreferenceelectrodestandardizationtechnique AT pedroavaldessosa unifiedbayesianestimatorofeegreferenceatinfinityrrestregularizedreferenceelectrodestandardizationtechnique |
_version_ |
1724875694064795648 |