GLOBAL STRUCTURAL ANALYSIS OF HIGH-RISE HOSPITAL BUILDING USING EARTHQUAKE RESISTANT DESIGN APPROACH

Building designed has 1 to 8 floors with the quality of concrete f'c of 33.2 MPa, steel quality (fy) 400 MPa, and shear stress of 240 MPa. The building is analyzed by 3D structure modeling through ETABS Version 9.7 program by following all the rules and regulations applicable in Indonesia, such...

Full description

Bibliographic Details
Main Author: Ayuddin Ayuddin
Format: Article
Language:Indonesian
Published: Universitas Mercu Buana 2020-04-01
Series:Jurnal Ilmiah SINERGI
Subjects:
Online Access:http://publikasi.mercubuana.ac.id/index.php/sinergi/article/view/6354
id doaj-617962b9fc1a4e6ebb1ba144ec341dfd
record_format Article
spelling doaj-617962b9fc1a4e6ebb1ba144ec341dfd2020-11-25T03:31:50ZindUniversitas Mercu BuanaJurnal Ilmiah SINERGI1410-23312460-12172020-04-012429510810.22441/sinergi.2020.2.0033367GLOBAL STRUCTURAL ANALYSIS OF HIGH-RISE HOSPITAL BUILDING USING EARTHQUAKE RESISTANT DESIGN APPROACHAyuddin Ayuddin0Department of Civil Engineering, Universitas Negeri GorontaloBuilding designed has 1 to 8 floors with the quality of concrete f'c of 33.2 MPa, steel quality (fy) 400 MPa, and shear stress of 240 MPa. The building is analyzed by 3D structure modeling through ETABS Version 9.7 program by following all the rules and regulations applicable in Indonesia, such as the guidance of building structure and non-building, SNI 1726: 2012. This building design system is a high-rise building structure planned with a portal frame system with beams and columns as the main elements of structures made of conventional concrete. The beam carries the load transversely of its length and transfers the load to the vertical columns that accumulate it. The column accepts the load axially by the beam and transfers the load to the foundation. This building structure uses a special moment frame structure system (SRPMK) structure, considering that the hospital building is safe against earthquakes and complains about the strong column weak beam concept.http://publikasi.mercubuana.ac.id/index.php/sinergi/article/view/6354structureearthquakebuilding
collection DOAJ
language Indonesian
format Article
sources DOAJ
author Ayuddin Ayuddin
spellingShingle Ayuddin Ayuddin
GLOBAL STRUCTURAL ANALYSIS OF HIGH-RISE HOSPITAL BUILDING USING EARTHQUAKE RESISTANT DESIGN APPROACH
Jurnal Ilmiah SINERGI
structure
earthquake
building
author_facet Ayuddin Ayuddin
author_sort Ayuddin Ayuddin
title GLOBAL STRUCTURAL ANALYSIS OF HIGH-RISE HOSPITAL BUILDING USING EARTHQUAKE RESISTANT DESIGN APPROACH
title_short GLOBAL STRUCTURAL ANALYSIS OF HIGH-RISE HOSPITAL BUILDING USING EARTHQUAKE RESISTANT DESIGN APPROACH
title_full GLOBAL STRUCTURAL ANALYSIS OF HIGH-RISE HOSPITAL BUILDING USING EARTHQUAKE RESISTANT DESIGN APPROACH
title_fullStr GLOBAL STRUCTURAL ANALYSIS OF HIGH-RISE HOSPITAL BUILDING USING EARTHQUAKE RESISTANT DESIGN APPROACH
title_full_unstemmed GLOBAL STRUCTURAL ANALYSIS OF HIGH-RISE HOSPITAL BUILDING USING EARTHQUAKE RESISTANT DESIGN APPROACH
title_sort global structural analysis of high-rise hospital building using earthquake resistant design approach
publisher Universitas Mercu Buana
series Jurnal Ilmiah SINERGI
issn 1410-2331
2460-1217
publishDate 2020-04-01
description Building designed has 1 to 8 floors with the quality of concrete f'c of 33.2 MPa, steel quality (fy) 400 MPa, and shear stress of 240 MPa. The building is analyzed by 3D structure modeling through ETABS Version 9.7 program by following all the rules and regulations applicable in Indonesia, such as the guidance of building structure and non-building, SNI 1726: 2012. This building design system is a high-rise building structure planned with a portal frame system with beams and columns as the main elements of structures made of conventional concrete. The beam carries the load transversely of its length and transfers the load to the vertical columns that accumulate it. The column accepts the load axially by the beam and transfers the load to the foundation. This building structure uses a special moment frame structure system (SRPMK) structure, considering that the hospital building is safe against earthquakes and complains about the strong column weak beam concept.
topic structure
earthquake
building
url http://publikasi.mercubuana.ac.id/index.php/sinergi/article/view/6354
work_keys_str_mv AT ayuddinayuddin globalstructuralanalysisofhighrisehospitalbuildingusingearthquakeresistantdesignapproach
_version_ 1724571339863359488