Thermal Disparity among Fingers and Its Amelioration by CO2-Water Bathing in Connective Tissue Disease Patients

Objective. Correlation between a low finger temperature and thermal disparity among fingers was studied in connective tissue disease (CTD) patients. Whether the thermal disparity may be ameliorated by hand immersion in a warm carbon dioxide- (CO2-) water bath was analyzed. Methods. CTD patients with...

Full description

Bibliographic Details
Main Authors: Shigeko Inokuma, Yasuo Kijima
Format: Article
Language:English
Published: Hindawi Limited 2021-01-01
Series:International Journal of Vascular Medicine
Online Access:http://dx.doi.org/10.1155/2021/6699029
id doaj-61c8f05698c243858090adf6d724c799
record_format Article
spelling doaj-61c8f05698c243858090adf6d724c7992021-07-02T13:40:36ZengHindawi LimitedInternational Journal of Vascular Medicine2090-28322021-01-01202110.1155/2021/6699029Thermal Disparity among Fingers and Its Amelioration by CO2-Water Bathing in Connective Tissue Disease PatientsShigeko Inokuma0Yasuo Kijima1Department of Allergy and RheumatismJapanese Red Cross Medical CenterObjective. Correlation between a low finger temperature and thermal disparity among fingers was studied in connective tissue disease (CTD) patients. Whether the thermal disparity may be ameliorated by hand immersion in a warm carbon dioxide- (CO2-) water bath was analyzed. Methods. CTD patients with suspected peripheral circulation disorder underwent a thermography test. From before to 30 min after hand immersion in CO2-water (CO2 bathing; 1000 ppm CO2, 42°C, 10 min), the nailfold temperatures were measured. The mean temperature (m-Temp) and the coefficient of variation of the temperature (CV=SD/m‐Temp of one hand; the mean of CVs of both hands was adopted as the indicator of thermal disparity) were monitored. The correlation between m-Temp and CV was also analyzed. Results. Forty-seven (45 females and 2 males) patients were included, 32 of whom had Raynaud’s phenomenon. The m-Temp was 30.8±3.0°C at the baseline, increased to 35.3±1.0°C immediately after CO2 bathing, and remained significantly higher than that at the baseline until 30 min after (32.1±1.9°C). The CV was 0.0291±0.0247 at the baseline, decreased to 0.0135±0.0039 immediately after CO2 bathing, and remained significantly lower than the baseline until 30 min after (0.0163±0.0143). Between m-Temp and CV, a negative correlation was observed throughout the measurements. Conclusion. Thermal disparity was observed at baseline measurement in CTD patients. Warm CO2 bathing markedly ameliorated the disparity, and this amelioration remained until after 30 min. Throughout the observation, the lower the m-Temp, the more severe the thermal disparity among fingers.http://dx.doi.org/10.1155/2021/6699029
collection DOAJ
language English
format Article
sources DOAJ
author Shigeko Inokuma
Yasuo Kijima
spellingShingle Shigeko Inokuma
Yasuo Kijima
Thermal Disparity among Fingers and Its Amelioration by CO2-Water Bathing in Connective Tissue Disease Patients
International Journal of Vascular Medicine
author_facet Shigeko Inokuma
Yasuo Kijima
author_sort Shigeko Inokuma
title Thermal Disparity among Fingers and Its Amelioration by CO2-Water Bathing in Connective Tissue Disease Patients
title_short Thermal Disparity among Fingers and Its Amelioration by CO2-Water Bathing in Connective Tissue Disease Patients
title_full Thermal Disparity among Fingers and Its Amelioration by CO2-Water Bathing in Connective Tissue Disease Patients
title_fullStr Thermal Disparity among Fingers and Its Amelioration by CO2-Water Bathing in Connective Tissue Disease Patients
title_full_unstemmed Thermal Disparity among Fingers and Its Amelioration by CO2-Water Bathing in Connective Tissue Disease Patients
title_sort thermal disparity among fingers and its amelioration by co2-water bathing in connective tissue disease patients
publisher Hindawi Limited
series International Journal of Vascular Medicine
issn 2090-2832
publishDate 2021-01-01
description Objective. Correlation between a low finger temperature and thermal disparity among fingers was studied in connective tissue disease (CTD) patients. Whether the thermal disparity may be ameliorated by hand immersion in a warm carbon dioxide- (CO2-) water bath was analyzed. Methods. CTD patients with suspected peripheral circulation disorder underwent a thermography test. From before to 30 min after hand immersion in CO2-water (CO2 bathing; 1000 ppm CO2, 42°C, 10 min), the nailfold temperatures were measured. The mean temperature (m-Temp) and the coefficient of variation of the temperature (CV=SD/m‐Temp of one hand; the mean of CVs of both hands was adopted as the indicator of thermal disparity) were monitored. The correlation between m-Temp and CV was also analyzed. Results. Forty-seven (45 females and 2 males) patients were included, 32 of whom had Raynaud’s phenomenon. The m-Temp was 30.8±3.0°C at the baseline, increased to 35.3±1.0°C immediately after CO2 bathing, and remained significantly higher than that at the baseline until 30 min after (32.1±1.9°C). The CV was 0.0291±0.0247 at the baseline, decreased to 0.0135±0.0039 immediately after CO2 bathing, and remained significantly lower than the baseline until 30 min after (0.0163±0.0143). Between m-Temp and CV, a negative correlation was observed throughout the measurements. Conclusion. Thermal disparity was observed at baseline measurement in CTD patients. Warm CO2 bathing markedly ameliorated the disparity, and this amelioration remained until after 30 min. Throughout the observation, the lower the m-Temp, the more severe the thermal disparity among fingers.
url http://dx.doi.org/10.1155/2021/6699029
work_keys_str_mv AT shigekoinokuma thermaldisparityamongfingersanditsameliorationbyco2waterbathinginconnectivetissuediseasepatients
AT yasuokijima thermaldisparityamongfingersanditsameliorationbyco2waterbathinginconnectivetissuediseasepatients
_version_ 1721328868574363648