STUDI PENGARUH SETTING RELE PENGAMAN UNTUK MEMINIMALKAN GANGGUAN SYMPATHETIC TRIP PADA PENYULANG BUNISARI-SUWUNG

<p class="Abstract"><em>Sympathetic Trip that happened in the electricity distribution system cause the healthy feeder distrupted because feel a disorder in feeder which affected by a disorder.A residual current that flows as a result of disruption of the one phase to ground on...

Full description

Bibliographic Details
Main Authors: I Komang Anom Astana Ady, I Gede Dyana Arjana, Cok Gede Indra Parta
Format: Article
Language:English
Published: Universitas Udayana 2016-11-01
Series:Majalah Ilmiah Teknologi Elektro
Subjects:
Online Access:http://ojs.unud.ac.id/index.php/JTE/article/view/20384
id doaj-6245f4f74ec3453091d3570555c18277
record_format Article
spelling doaj-6245f4f74ec3453091d3570555c182772020-11-24T22:52:25ZengUniversitas UdayanaMajalah Ilmiah Teknologi Elektro1693-29512503-23722016-11-01152535814956STUDI PENGARUH SETTING RELE PENGAMAN UNTUK MEMINIMALKAN GANGGUAN SYMPATHETIC TRIP PADA PENYULANG BUNISARI-SUWUNGI Komang Anom Astana Ady0I Gede Dyana Arjana1Cok Gede Indra Parta2universitas udayanaTeknik ElektroTeknik Elektro<p class="Abstract"><em>Sympathetic Trip that happened in the electricity distribution system cause the healthy feeder distrupted because feel a disorder in feeder which affected by a disorder.A residual current that flows as a result of disruption of the one phase to ground on the Bunisari feeder as much as 183,9 A will be perceived by the same phase in the Suwung feeder which has a residual current of 196,9 A, that resulting in the accumulation of capacitive current as much as 380,8 A.The efforts obtained to prevent the Sympathetic trip back with ground fault relay setting as Iset = 25,72 A, tms = 0,11 SI with relay working time for 0,27 seconds <span>and for Suwung feeder is obtained Iset = 24,59 A, tms  = 0,115 SI with </span>relay working time<span> for 0,286 seconds</span></em>.</p>http://ojs.unud.ac.id/index.php/JTE/article/view/20384Sistem proteksi, setting ground fault relay, Simpatitik Trip.
collection DOAJ
language English
format Article
sources DOAJ
author I Komang Anom Astana Ady
I Gede Dyana Arjana
Cok Gede Indra Parta
spellingShingle I Komang Anom Astana Ady
I Gede Dyana Arjana
Cok Gede Indra Parta
STUDI PENGARUH SETTING RELE PENGAMAN UNTUK MEMINIMALKAN GANGGUAN SYMPATHETIC TRIP PADA PENYULANG BUNISARI-SUWUNG
Majalah Ilmiah Teknologi Elektro
Sistem proteksi, setting ground fault relay, Simpatitik Trip.
author_facet I Komang Anom Astana Ady
I Gede Dyana Arjana
Cok Gede Indra Parta
author_sort I Komang Anom Astana Ady
title STUDI PENGARUH SETTING RELE PENGAMAN UNTUK MEMINIMALKAN GANGGUAN SYMPATHETIC TRIP PADA PENYULANG BUNISARI-SUWUNG
title_short STUDI PENGARUH SETTING RELE PENGAMAN UNTUK MEMINIMALKAN GANGGUAN SYMPATHETIC TRIP PADA PENYULANG BUNISARI-SUWUNG
title_full STUDI PENGARUH SETTING RELE PENGAMAN UNTUK MEMINIMALKAN GANGGUAN SYMPATHETIC TRIP PADA PENYULANG BUNISARI-SUWUNG
title_fullStr STUDI PENGARUH SETTING RELE PENGAMAN UNTUK MEMINIMALKAN GANGGUAN SYMPATHETIC TRIP PADA PENYULANG BUNISARI-SUWUNG
title_full_unstemmed STUDI PENGARUH SETTING RELE PENGAMAN UNTUK MEMINIMALKAN GANGGUAN SYMPATHETIC TRIP PADA PENYULANG BUNISARI-SUWUNG
title_sort studi pengaruh setting rele pengaman untuk meminimalkan gangguan sympathetic trip pada penyulang bunisari-suwung
publisher Universitas Udayana
series Majalah Ilmiah Teknologi Elektro
issn 1693-2951
2503-2372
publishDate 2016-11-01
description <p class="Abstract"><em>Sympathetic Trip that happened in the electricity distribution system cause the healthy feeder distrupted because feel a disorder in feeder which affected by a disorder.A residual current that flows as a result of disruption of the one phase to ground on the Bunisari feeder as much as 183,9 A will be perceived by the same phase in the Suwung feeder which has a residual current of 196,9 A, that resulting in the accumulation of capacitive current as much as 380,8 A.The efforts obtained to prevent the Sympathetic trip back with ground fault relay setting as Iset = 25,72 A, tms = 0,11 SI with relay working time for 0,27 seconds <span>and for Suwung feeder is obtained Iset = 24,59 A, tms  = 0,115 SI with </span>relay working time<span> for 0,286 seconds</span></em>.</p>
topic Sistem proteksi, setting ground fault relay, Simpatitik Trip.
url http://ojs.unud.ac.id/index.php/JTE/article/view/20384
work_keys_str_mv AT ikomanganomastanaady studipengaruhsettingrelepengamanuntukmeminimalkangangguansympathetictrippadapenyulangbunisarisuwung
AT igededyanaarjana studipengaruhsettingrelepengamanuntukmeminimalkangangguansympathetictrippadapenyulangbunisarisuwung
AT cokgedeindraparta studipengaruhsettingrelepengamanuntukmeminimalkangangguansympathetictrippadapenyulangbunisarisuwung
_version_ 1725666307472359424