Multi-Night Validation of a Sleep Tracking Ring in Adolescents Compared with a Research Actigraph and Polysomnography

Nicholas IYN Chee,* Shohreh Ghorbani,* Hosein Aghayan Golkashani, Ruth LF Leong, Ju Lynn Ong, Michael WL Chee Centre for Sleep and Cognition, Yong Loo Lin School of Medicine, National University of Singapore, Singapore*These authors contributed equally to this workCorrespondence: Michael WL CheeCent...

Full description

Bibliographic Details
Main Authors: Chee NIYN, Ghorbani S, Golkashani HA, Leong RLF, Ong JL, Chee MWL
Format: Article
Language:English
Published: Dove Medical Press 2021-02-01
Series:Nature and Science of Sleep
Subjects:
Online Access:https://www.dovepress.com/multi-night-validation-of-a-sleep-tracking-ring-in-adolescents-compare-peer-reviewed-article-NSS
id doaj-629e1bb88cd942b5a8b66f31e24587e5
record_format Article
spelling doaj-629e1bb88cd942b5a8b66f31e24587e52021-02-17T01:13:59ZengDove Medical PressNature and Science of Sleep1179-16082021-02-01Volume 1317719062092Multi-Night Validation of a Sleep Tracking Ring in Adolescents Compared with a Research Actigraph and PolysomnographyChee NIYNGhorbani SGolkashani HALeong RLFOng JLChee MWLNicholas IYN Chee,* Shohreh Ghorbani,* Hosein Aghayan Golkashani, Ruth LF Leong, Ju Lynn Ong, Michael WL Chee Centre for Sleep and Cognition, Yong Loo Lin School of Medicine, National University of Singapore, Singapore*These authors contributed equally to this workCorrespondence: Michael WL CheeCentre for Sleep and Cognition, Yong Loo Lin School of Medicine, MD1 Level 13 Rm 05B, National University of Singapore, 117549, SingaporeTel +65 66013199Email michael.chee@nus.edu.sgBackground: Wearable devices have tremendous potential for large-scale longitudinal measurement of sleep, but their accuracy needs to be validated. We compared the performance of the multisensor Oura ring (Oura Health Oy, Oulu, Finland) to polysomnography (PSG) and a research actigraph in healthy adolescents.Methods: Fifty-three adolescents (28 females; aged 15– 19 years) underwent overnight PSG monitoring while wearing both an Oura ring and Actiwatch 2 (Philips Respironics, USA). Measurements were made over multiple nights and across three levels of sleep opportunity (5 nights with either 6.5 or 8h, and 3 nights with 9h). Actiwatch data at two sensitivity settings were analyzed. Discrepancies in estimated sleep measures as well as sleep-wake, and sleep stage agreements were evaluated using Bland–Altman plots and epoch-by-epoch (EBE) analyses.Results: Compared with PSG, Oura consistently underestimated TST by an average of 32.8 to 47.3 minutes (Ps < 0.001) across the different TIB conditions; Actiwatch 2 at its default setting underestimated TST by 25.8 to 33.9 minutes. Oura significantly overestimated WASO by an average of 30.7 to 46.3 minutes. It was comparable to Actiwatch 2 at default sensitivity in the 6.5, and 8h TIB conditions. Relative to PSG, Oura significantly underestimated REM sleep (12.8 to 19.5 minutes) and light sleep (51.1 to 81.2 minutes) but overestimated N3 by 31.5 to 46.8 minutes (Ps < 0.01). EBE analyses demonstrated excellent sleep-wake accuracies, specificities, and sensitivities – between 0.88 and 0.89 across all TIBs.Conclusion: The Oura ring yielded comparable sleep measurement to research grade actigraphy at the latter’s default settings. Sleep staging needs improvement. However, the device appears adequate for characterizing the effect of sleep duration manipulation on adolescent sleep macro-architecture.Keywords: validation, adolescents, wearable, polysomnography, actigraphyhttps://www.dovepress.com/multi-night-validation-of-a-sleep-tracking-ring-in-adolescents-compare-peer-reviewed-article-NSSvalidationadolescentswearablepolysomnographyactigraphy
collection DOAJ
language English
format Article
sources DOAJ
author Chee NIYN
Ghorbani S
Golkashani HA
Leong RLF
Ong JL
Chee MWL
spellingShingle Chee NIYN
Ghorbani S
Golkashani HA
Leong RLF
Ong JL
Chee MWL
Multi-Night Validation of a Sleep Tracking Ring in Adolescents Compared with a Research Actigraph and Polysomnography
Nature and Science of Sleep
validation
adolescents
wearable
polysomnography
actigraphy
author_facet Chee NIYN
Ghorbani S
Golkashani HA
Leong RLF
Ong JL
Chee MWL
author_sort Chee NIYN
title Multi-Night Validation of a Sleep Tracking Ring in Adolescents Compared with a Research Actigraph and Polysomnography
title_short Multi-Night Validation of a Sleep Tracking Ring in Adolescents Compared with a Research Actigraph and Polysomnography
title_full Multi-Night Validation of a Sleep Tracking Ring in Adolescents Compared with a Research Actigraph and Polysomnography
title_fullStr Multi-Night Validation of a Sleep Tracking Ring in Adolescents Compared with a Research Actigraph and Polysomnography
title_full_unstemmed Multi-Night Validation of a Sleep Tracking Ring in Adolescents Compared with a Research Actigraph and Polysomnography
title_sort multi-night validation of a sleep tracking ring in adolescents compared with a research actigraph and polysomnography
publisher Dove Medical Press
series Nature and Science of Sleep
issn 1179-1608
publishDate 2021-02-01
description Nicholas IYN Chee,* Shohreh Ghorbani,* Hosein Aghayan Golkashani, Ruth LF Leong, Ju Lynn Ong, Michael WL Chee Centre for Sleep and Cognition, Yong Loo Lin School of Medicine, National University of Singapore, Singapore*These authors contributed equally to this workCorrespondence: Michael WL CheeCentre for Sleep and Cognition, Yong Loo Lin School of Medicine, MD1 Level 13 Rm 05B, National University of Singapore, 117549, SingaporeTel +65 66013199Email michael.chee@nus.edu.sgBackground: Wearable devices have tremendous potential for large-scale longitudinal measurement of sleep, but their accuracy needs to be validated. We compared the performance of the multisensor Oura ring (Oura Health Oy, Oulu, Finland) to polysomnography (PSG) and a research actigraph in healthy adolescents.Methods: Fifty-three adolescents (28 females; aged 15– 19 years) underwent overnight PSG monitoring while wearing both an Oura ring and Actiwatch 2 (Philips Respironics, USA). Measurements were made over multiple nights and across three levels of sleep opportunity (5 nights with either 6.5 or 8h, and 3 nights with 9h). Actiwatch data at two sensitivity settings were analyzed. Discrepancies in estimated sleep measures as well as sleep-wake, and sleep stage agreements were evaluated using Bland–Altman plots and epoch-by-epoch (EBE) analyses.Results: Compared with PSG, Oura consistently underestimated TST by an average of 32.8 to 47.3 minutes (Ps < 0.001) across the different TIB conditions; Actiwatch 2 at its default setting underestimated TST by 25.8 to 33.9 minutes. Oura significantly overestimated WASO by an average of 30.7 to 46.3 minutes. It was comparable to Actiwatch 2 at default sensitivity in the 6.5, and 8h TIB conditions. Relative to PSG, Oura significantly underestimated REM sleep (12.8 to 19.5 minutes) and light sleep (51.1 to 81.2 minutes) but overestimated N3 by 31.5 to 46.8 minutes (Ps < 0.01). EBE analyses demonstrated excellent sleep-wake accuracies, specificities, and sensitivities – between 0.88 and 0.89 across all TIBs.Conclusion: The Oura ring yielded comparable sleep measurement to research grade actigraphy at the latter’s default settings. Sleep staging needs improvement. However, the device appears adequate for characterizing the effect of sleep duration manipulation on adolescent sleep macro-architecture.Keywords: validation, adolescents, wearable, polysomnography, actigraphy
topic validation
adolescents
wearable
polysomnography
actigraphy
url https://www.dovepress.com/multi-night-validation-of-a-sleep-tracking-ring-in-adolescents-compare-peer-reviewed-article-NSS
work_keys_str_mv AT cheeniyn multinightvalidationofasleeptrackingringinadolescentscomparedwitharesearchactigraphandpolysomnography
AT ghorbanis multinightvalidationofasleeptrackingringinadolescentscomparedwitharesearchactigraphandpolysomnography
AT golkashaniha multinightvalidationofasleeptrackingringinadolescentscomparedwitharesearchactigraphandpolysomnography
AT leongrlf multinightvalidationofasleeptrackingringinadolescentscomparedwitharesearchactigraphandpolysomnography
AT ongjl multinightvalidationofasleeptrackingringinadolescentscomparedwitharesearchactigraphandpolysomnography
AT cheemwl multinightvalidationofasleeptrackingringinadolescentscomparedwitharesearchactigraphandpolysomnography
_version_ 1724265674054828032