Use of Multiple Temperature Logger Models Can Alter Conclusions

Remote temperature loggers are often used to measure water temperatures for ecological studies and by regulatory agencies to determine whether water quality standards are being maintained. Equipment specifications are often given a cursory review in the methods; however, the effect of temperature lo...

Full description

Bibliographic Details
Main Authors: Joanna B. Whittier, Jacob T. Westhoff, Craig P. Paukert, Robin M. Rotman
Format: Article
Language:English
Published: MDPI AG 2020-03-01
Series:Water
Subjects:
Online Access:https://www.mdpi.com/2073-4441/12/3/668
id doaj-62e469f57bf843bea142e3a21403931c
record_format Article
spelling doaj-62e469f57bf843bea142e3a21403931c2020-11-25T02:15:07ZengMDPI AGWater2073-44412020-03-0112366810.3390/w12030668w12030668Use of Multiple Temperature Logger Models Can Alter ConclusionsJoanna B. Whittier0Jacob T. Westhoff1Craig P. Paukert2Robin M. Rotman3School of Natural Resources, University of Missouri, Columbia, MO, USAMissouri Department of Conservation, Columbia, MO, USAU.S. Geological Survey, Missouri Cooperative Fish and Wildlife Research Unit, School of Natural Resources, University of Missouri, Columbia, MO, USASchool of Natural Resources, University of Missouri, Columbia, MO, USARemote temperature loggers are often used to measure water temperatures for ecological studies and by regulatory agencies to determine whether water quality standards are being maintained. Equipment specifications are often given a cursory review in the methods; however, the effect of temperature logger model is rarely addressed in the discussion. In a laboratory environment, we compared measurements from three models of temperature loggers at 5 to 40 °C to better understand the utility of these devices. Mean water temperatures recorded by logger models differed statistically even for those with similar accuracy specifications, but were still within manufacturer accuracy specifications. Maximum mean temperature difference between models was 0.4 °C which could have regulatory and ecological implications, such as when a 0.3 °C temperature change triggers a water quality violation or increases species mortality rates. Additionally, precision should be reported as the overall precision (including a consideration of significant digits) for combined model types which in our experiment was 0.7 °C, not the ≤0.4 °C for individual models. Our results affirm that analyzing data collected by different logger models can result in potentially erroneous conclusions when <1 °C difference has regulatory compliance or ecological implications and that combining data from multiple logger models can reduce the overall precision of results.https://www.mdpi.com/2073-4441/12/3/668instrumentationenvironmental regulationaquatic ecologyprecisionaccuracy
collection DOAJ
language English
format Article
sources DOAJ
author Joanna B. Whittier
Jacob T. Westhoff
Craig P. Paukert
Robin M. Rotman
spellingShingle Joanna B. Whittier
Jacob T. Westhoff
Craig P. Paukert
Robin M. Rotman
Use of Multiple Temperature Logger Models Can Alter Conclusions
Water
instrumentation
environmental regulation
aquatic ecology
precision
accuracy
author_facet Joanna B. Whittier
Jacob T. Westhoff
Craig P. Paukert
Robin M. Rotman
author_sort Joanna B. Whittier
title Use of Multiple Temperature Logger Models Can Alter Conclusions
title_short Use of Multiple Temperature Logger Models Can Alter Conclusions
title_full Use of Multiple Temperature Logger Models Can Alter Conclusions
title_fullStr Use of Multiple Temperature Logger Models Can Alter Conclusions
title_full_unstemmed Use of Multiple Temperature Logger Models Can Alter Conclusions
title_sort use of multiple temperature logger models can alter conclusions
publisher MDPI AG
series Water
issn 2073-4441
publishDate 2020-03-01
description Remote temperature loggers are often used to measure water temperatures for ecological studies and by regulatory agencies to determine whether water quality standards are being maintained. Equipment specifications are often given a cursory review in the methods; however, the effect of temperature logger model is rarely addressed in the discussion. In a laboratory environment, we compared measurements from three models of temperature loggers at 5 to 40 °C to better understand the utility of these devices. Mean water temperatures recorded by logger models differed statistically even for those with similar accuracy specifications, but were still within manufacturer accuracy specifications. Maximum mean temperature difference between models was 0.4 °C which could have regulatory and ecological implications, such as when a 0.3 °C temperature change triggers a water quality violation or increases species mortality rates. Additionally, precision should be reported as the overall precision (including a consideration of significant digits) for combined model types which in our experiment was 0.7 °C, not the ≤0.4 °C for individual models. Our results affirm that analyzing data collected by different logger models can result in potentially erroneous conclusions when <1 °C difference has regulatory compliance or ecological implications and that combining data from multiple logger models can reduce the overall precision of results.
topic instrumentation
environmental regulation
aquatic ecology
precision
accuracy
url https://www.mdpi.com/2073-4441/12/3/668
work_keys_str_mv AT joannabwhittier useofmultipletemperatureloggermodelscanalterconclusions
AT jacobtwesthoff useofmultipletemperatureloggermodelscanalterconclusions
AT craigppaukert useofmultipletemperatureloggermodelscanalterconclusions
AT robinmrotman useofmultipletemperatureloggermodelscanalterconclusions
_version_ 1724897725459202048