Comparison of hemodynamic and metabolic stress responses caused by endotracheal tube and Proseal laryngeal mask airway in laparoscopic cholecystectomy

Background: We aimed to compare hemodynamic and endocrine alterations caused by stress response due to Proseal laryngeal mask airway and endotracheal tube usage in laparoscopic cholecystectomy. Materials and Methods: Sixty-three ASA I-II patients scheduled for elective laparoscopic cholecystectomy w...

Full description

Bibliographic Details
Main Authors: Handan Güleç, Türkay Çakan, Halil Yaman, Aytül Sadan Kilinç, Hülya Basar
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2012-01-01
Series:Journal of Research in Medical Sciences
Subjects:
Online Access:http://www.jmsjournal.net/article.asp?issn=1735-1995;year=2012;volume=17;issue=2;spage=148;epage=153;aulast=Güleç
id doaj-63210026177b475085a40d2b01a30fa5
record_format Article
spelling doaj-63210026177b475085a40d2b01a30fa52020-11-24T21:51:11ZengWolters Kluwer Medknow PublicationsJournal of Research in Medical Sciences1735-19951735-71362012-01-01172148153Comparison of hemodynamic and metabolic stress responses caused by endotracheal tube and Proseal laryngeal mask airway in laparoscopic cholecystectomyHandan GüleçTürkay ÇakanHalil YamanAytül Sadan KilinçHülya BasarBackground: We aimed to compare hemodynamic and endocrine alterations caused by stress response due to Proseal laryngeal mask airway and endotracheal tube usage in laparoscopic cholecystectomy. Materials and Methods: Sixty-three ASA I-II patients scheduled for elective laparoscopic cholecystectomy were included in the study. Patients were randomly allocated into two groups of endotracheal tube and Proseal laryngeal mask airway. Standard general anaesthesia was performed in both groups with the same drugs in induction and maintenance of anaesthesia. After anaesthesia induction and 20 minutes after CO 2 insufflations, venous blood samples were obtained for measuring adrenalin, noradrenalin, dopamine and cortisol levels. Hemodynamic and respiratory parameters were recorded at the 1 st , 5 th , 15 th , 30 th and 45 th minutes after the insertion of airway devices. Results: No statistically significant differences in age, body mass index, gender, ASA physical status, and operation time were found between the groups (p > 0.05). Changes in hemodynamic and respiratory parameters were not statistically significant when compared between and within groups (p > 0.05). Although no statistically significant differences were observed between and within groups when adrenalin, noradrenalin and dopamine values were compared, serum cortisol levels after CO 2 insufflation in PLMA group were significantly lower than the ETT group (p = 0.024). When serum cortisol levels were compared within groups, cortisol levels 20 minutes after CO 2 insufflation were significantly higher (46.1 (9.5-175.7) and 27.0 (8.3-119.4) in the ETT and PLMA groups, respectively) than cortisol levels after anaesthesia induction (11.3 (2.8-92.5) and 16.6 (4.4-45.4) in the ETT and PLMA groups, respectively) in both groups (p = 0.001). Conclusion: PLMA usage is a suitable, effective and safe alternative to ETT in laparoscopic cholecystectomy patients with lower metabolic stress.http://www.jmsjournal.net/article.asp?issn=1735-1995;year=2012;volume=17;issue=2;spage=148;epage=153;aulast=GüleçEndotracheal TubeProseal Laryngeal Mask Airway (PLMA)Hemodynamic ResponseMetabolic Response
collection DOAJ
language English
format Article
sources DOAJ
author Handan Güleç
Türkay Çakan
Halil Yaman
Aytül Sadan Kilinç
Hülya Basar
spellingShingle Handan Güleç
Türkay Çakan
Halil Yaman
Aytül Sadan Kilinç
Hülya Basar
Comparison of hemodynamic and metabolic stress responses caused by endotracheal tube and Proseal laryngeal mask airway in laparoscopic cholecystectomy
Journal of Research in Medical Sciences
Endotracheal Tube
Proseal Laryngeal Mask Airway (PLMA)
Hemodynamic Response
Metabolic Response
author_facet Handan Güleç
Türkay Çakan
Halil Yaman
Aytül Sadan Kilinç
Hülya Basar
author_sort Handan Güleç
title Comparison of hemodynamic and metabolic stress responses caused by endotracheal tube and Proseal laryngeal mask airway in laparoscopic cholecystectomy
title_short Comparison of hemodynamic and metabolic stress responses caused by endotracheal tube and Proseal laryngeal mask airway in laparoscopic cholecystectomy
title_full Comparison of hemodynamic and metabolic stress responses caused by endotracheal tube and Proseal laryngeal mask airway in laparoscopic cholecystectomy
title_fullStr Comparison of hemodynamic and metabolic stress responses caused by endotracheal tube and Proseal laryngeal mask airway in laparoscopic cholecystectomy
title_full_unstemmed Comparison of hemodynamic and metabolic stress responses caused by endotracheal tube and Proseal laryngeal mask airway in laparoscopic cholecystectomy
title_sort comparison of hemodynamic and metabolic stress responses caused by endotracheal tube and proseal laryngeal mask airway in laparoscopic cholecystectomy
publisher Wolters Kluwer Medknow Publications
series Journal of Research in Medical Sciences
issn 1735-1995
1735-7136
publishDate 2012-01-01
description Background: We aimed to compare hemodynamic and endocrine alterations caused by stress response due to Proseal laryngeal mask airway and endotracheal tube usage in laparoscopic cholecystectomy. Materials and Methods: Sixty-three ASA I-II patients scheduled for elective laparoscopic cholecystectomy were included in the study. Patients were randomly allocated into two groups of endotracheal tube and Proseal laryngeal mask airway. Standard general anaesthesia was performed in both groups with the same drugs in induction and maintenance of anaesthesia. After anaesthesia induction and 20 minutes after CO 2 insufflations, venous blood samples were obtained for measuring adrenalin, noradrenalin, dopamine and cortisol levels. Hemodynamic and respiratory parameters were recorded at the 1 st , 5 th , 15 th , 30 th and 45 th minutes after the insertion of airway devices. Results: No statistically significant differences in age, body mass index, gender, ASA physical status, and operation time were found between the groups (p > 0.05). Changes in hemodynamic and respiratory parameters were not statistically significant when compared between and within groups (p > 0.05). Although no statistically significant differences were observed between and within groups when adrenalin, noradrenalin and dopamine values were compared, serum cortisol levels after CO 2 insufflation in PLMA group were significantly lower than the ETT group (p = 0.024). When serum cortisol levels were compared within groups, cortisol levels 20 minutes after CO 2 insufflation were significantly higher (46.1 (9.5-175.7) and 27.0 (8.3-119.4) in the ETT and PLMA groups, respectively) than cortisol levels after anaesthesia induction (11.3 (2.8-92.5) and 16.6 (4.4-45.4) in the ETT and PLMA groups, respectively) in both groups (p = 0.001). Conclusion: PLMA usage is a suitable, effective and safe alternative to ETT in laparoscopic cholecystectomy patients with lower metabolic stress.
topic Endotracheal Tube
Proseal Laryngeal Mask Airway (PLMA)
Hemodynamic Response
Metabolic Response
url http://www.jmsjournal.net/article.asp?issn=1735-1995;year=2012;volume=17;issue=2;spage=148;epage=153;aulast=Güleç
work_keys_str_mv AT handangulec comparisonofhemodynamicandmetabolicstressresponsescausedbyendotrachealtubeandproseallaryngealmaskairwayinlaparoscopiccholecystectomy
AT turkaycakan comparisonofhemodynamicandmetabolicstressresponsescausedbyendotrachealtubeandproseallaryngealmaskairwayinlaparoscopiccholecystectomy
AT halilyaman comparisonofhemodynamicandmetabolicstressresponsescausedbyendotrachealtubeandproseallaryngealmaskairwayinlaparoscopiccholecystectomy
AT aytulsadankilinc comparisonofhemodynamicandmetabolicstressresponsescausedbyendotrachealtubeandproseallaryngealmaskairwayinlaparoscopiccholecystectomy
AT hulyabasar comparisonofhemodynamicandmetabolicstressresponsescausedbyendotrachealtubeandproseallaryngealmaskairwayinlaparoscopiccholecystectomy
_version_ 1725880051494289408