Does self-ligating brackets type influence the hysteresis, activation and deactivation forces of superelastic NiTi archwires?

OBJECTIVE: To compare hysteresis, activation and deactivation forces produced by first-order deformation of Contour 0.014-in NiTi wire (Aditek, Brazil) in four brands of self-ligating brackets: Damon MX, Easy Clip, Smart Clip and In-Ovation. METHODS: Activation and deactivation forces were measured...

Full description

Bibliographic Details
Main Authors: José Rino Neto, Gilberto Vilanova Queiroz, João Batista de Paiva, Rafael Yagüe Ballester
Format: Article
Language:English
Published: Dental Press Editora 2013-02-01
Series:Dental Press Journal of Orthodontics
Subjects:
Online Access:http://www.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512013000100018
Description
Summary:OBJECTIVE: To compare hysteresis, activation and deactivation forces produced by first-order deformation of Contour 0.014-in NiTi wire (Aditek, Brazil) in four brands of self-ligating brackets: Damon MX, Easy Clip, Smart Clip and In-Ovation. METHODS: Activation and deactivation forces were measured in an Instron universal tensile machine at 3 mm/minute speed to a total displacement of 4 mm. Tests were repeated eight times for each bracket/wire combination. Statistical analysis comprised ANOVA and Tukey's multiple comparisons test. RESULTS: Using a 4-mm deformation, mean activation forces increased in the following order: Damon = 222 gf, Easy Clip = 228 gf, In-Ovation = 240 gf and Smart Clip = 306 gf. The same order was observed for mean hysteresis values, i.e., 128 gf, 140 gf, 150 gf and 206 gf, respectively. The respective values of deactivation forces for the Damon, Easy Clip, In-Ovation and Smart Clip brackets were 94 gf, 88 gf, 90 gf and 100 gf. CONCLUSIONS: Brackets with higher activation forces were accompanied by higher hysteresis values, which resulted in clinically similar deactivation forces, regardless of the type of self-ligating brackets used.<br>OBJETIVO: comparar as forças de ativação, desativação e histerese produzidas por deformação de primeira ordem do fio superelástico Contour NiTi 0,014" (Aditek®) em quatro modelos de braquetes autoligáveis: Damon MX, Easy Clip, Smart Clip e In-Ovation. MÉTODOS: as forças de ativação e desativação foram medidas em máquina universal de tração Instron com velocidade de 3mm/minuto e deslocamento de 4mm. Em cada combinação braquete/fio foram executadas oito repetições. A análise estatística empregou ANOVA e o Teste de Comparações Múltiplas de Tukey. RESULTADOS: com 4mm de deformação, as forças médias de ativação foram, em ordem crescente, Damon = 222gf, Easy Clip = 228gf, In-Ovation = 240gf e Smart-Clip = 306gf; a mesma ordem foi observada nas histereses médias, cujos valores foram, respectivamente, 128gf, 140gf, 150gf e 206gf; os valores das forças de desativação foram, respectivamente, 94gf, 88gf, 90gf e 100gf. CONCLUSÃO: os braquetes com maiores valores nas forças de ativação foram acompanhados por maiores valores na histerese, o que resultou em forças de desativação clinicamente semelhantes, independentemente do tipo de braquete autoligável utilizado.
ISSN:2176-9451
2177-6709