Does self-ligating brackets type influence the hysteresis, activation and deactivation forces of superelastic NiTi archwires?

OBJECTIVE: To compare hysteresis, activation and deactivation forces produced by first-order deformation of Contour 0.014-in NiTi wire (Aditek, Brazil) in four brands of self-ligating brackets: Damon MX, Easy Clip, Smart Clip and In-Ovation. METHODS: Activation and deactivation forces were measured...

Full description

Bibliographic Details
Main Authors: José Rino Neto, Gilberto Vilanova Queiroz, João Batista de Paiva, Rafael Yagüe Ballester
Format: Article
Language:English
Published: Dental Press Editora 2013-02-01
Series:Dental Press Journal of Orthodontics
Subjects:
Online Access:http://www.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512013000100018
id doaj-638524dd65024d5d8db5f2fe5eeb998f
record_format Article
spelling doaj-638524dd65024d5d8db5f2fe5eeb998f2020-11-25T00:54:28ZengDental Press Editora Dental Press Journal of Orthodontics 2176-94512177-67092013-02-011818185Does self-ligating brackets type influence the hysteresis, activation and deactivation forces of superelastic NiTi archwires?José Rino NetoGilberto Vilanova QueirozJoão Batista de PaivaRafael Yagüe BallesterOBJECTIVE: To compare hysteresis, activation and deactivation forces produced by first-order deformation of Contour 0.014-in NiTi wire (Aditek, Brazil) in four brands of self-ligating brackets: Damon MX, Easy Clip, Smart Clip and In-Ovation. METHODS: Activation and deactivation forces were measured in an Instron universal tensile machine at 3 mm/minute speed to a total displacement of 4 mm. Tests were repeated eight times for each bracket/wire combination. Statistical analysis comprised ANOVA and Tukey's multiple comparisons test. RESULTS: Using a 4-mm deformation, mean activation forces increased in the following order: Damon = 222 gf, Easy Clip = 228 gf, In-Ovation = 240 gf and Smart Clip = 306 gf. The same order was observed for mean hysteresis values, i.e., 128 gf, 140 gf, 150 gf and 206 gf, respectively. The respective values of deactivation forces for the Damon, Easy Clip, In-Ovation and Smart Clip brackets were 94 gf, 88 gf, 90 gf and 100 gf. CONCLUSIONS: Brackets with higher activation forces were accompanied by higher hysteresis values, which resulted in clinically similar deactivation forces, regardless of the type of self-ligating brackets used.<br>OBJETIVO: comparar as forças de ativação, desativação e histerese produzidas por deformação de primeira ordem do fio superelástico Contour NiTi 0,014" (Aditek®) em quatro modelos de braquetes autoligáveis: Damon MX, Easy Clip, Smart Clip e In-Ovation. MÉTODOS: as forças de ativação e desativação foram medidas em máquina universal de tração Instron com velocidade de 3mm/minuto e deslocamento de 4mm. Em cada combinação braquete/fio foram executadas oito repetições. A análise estatística empregou ANOVA e o Teste de Comparações Múltiplas de Tukey. RESULTADOS: com 4mm de deformação, as forças médias de ativação foram, em ordem crescente, Damon = 222gf, Easy Clip = 228gf, In-Ovation = 240gf e Smart-Clip = 306gf; a mesma ordem foi observada nas histereses médias, cujos valores foram, respectivamente, 128gf, 140gf, 150gf e 206gf; os valores das forças de desativação foram, respectivamente, 94gf, 88gf, 90gf e 100gf. CONCLUSÃO: os braquetes com maiores valores nas forças de ativação foram acompanhados por maiores valores na histerese, o que resultou em forças de desativação clinicamente semelhantes, independentemente do tipo de braquete autoligável utilizado.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512013000100018Ortodontia corretivaFios ortodônticosAparelhos ortodônticosCorrective orthodonticsOrthodontic bracketsOrthodontic wires
collection DOAJ
language English
format Article
sources DOAJ
author José Rino Neto
Gilberto Vilanova Queiroz
João Batista de Paiva
Rafael Yagüe Ballester
spellingShingle José Rino Neto
Gilberto Vilanova Queiroz
João Batista de Paiva
Rafael Yagüe Ballester
Does self-ligating brackets type influence the hysteresis, activation and deactivation forces of superelastic NiTi archwires?
Dental Press Journal of Orthodontics
Ortodontia corretiva
Fios ortodônticos
Aparelhos ortodônticos
Corrective orthodontics
Orthodontic brackets
Orthodontic wires
author_facet José Rino Neto
Gilberto Vilanova Queiroz
João Batista de Paiva
Rafael Yagüe Ballester
author_sort José Rino Neto
title Does self-ligating brackets type influence the hysteresis, activation and deactivation forces of superelastic NiTi archwires?
title_short Does self-ligating brackets type influence the hysteresis, activation and deactivation forces of superelastic NiTi archwires?
title_full Does self-ligating brackets type influence the hysteresis, activation and deactivation forces of superelastic NiTi archwires?
title_fullStr Does self-ligating brackets type influence the hysteresis, activation and deactivation forces of superelastic NiTi archwires?
title_full_unstemmed Does self-ligating brackets type influence the hysteresis, activation and deactivation forces of superelastic NiTi archwires?
title_sort does self-ligating brackets type influence the hysteresis, activation and deactivation forces of superelastic niti archwires?
publisher Dental Press Editora
series Dental Press Journal of Orthodontics
issn 2176-9451
2177-6709
publishDate 2013-02-01
description OBJECTIVE: To compare hysteresis, activation and deactivation forces produced by first-order deformation of Contour 0.014-in NiTi wire (Aditek, Brazil) in four brands of self-ligating brackets: Damon MX, Easy Clip, Smart Clip and In-Ovation. METHODS: Activation and deactivation forces were measured in an Instron universal tensile machine at 3 mm/minute speed to a total displacement of 4 mm. Tests were repeated eight times for each bracket/wire combination. Statistical analysis comprised ANOVA and Tukey's multiple comparisons test. RESULTS: Using a 4-mm deformation, mean activation forces increased in the following order: Damon = 222 gf, Easy Clip = 228 gf, In-Ovation = 240 gf and Smart Clip = 306 gf. The same order was observed for mean hysteresis values, i.e., 128 gf, 140 gf, 150 gf and 206 gf, respectively. The respective values of deactivation forces for the Damon, Easy Clip, In-Ovation and Smart Clip brackets were 94 gf, 88 gf, 90 gf and 100 gf. CONCLUSIONS: Brackets with higher activation forces were accompanied by higher hysteresis values, which resulted in clinically similar deactivation forces, regardless of the type of self-ligating brackets used.<br>OBJETIVO: comparar as forças de ativação, desativação e histerese produzidas por deformação de primeira ordem do fio superelástico Contour NiTi 0,014" (Aditek®) em quatro modelos de braquetes autoligáveis: Damon MX, Easy Clip, Smart Clip e In-Ovation. MÉTODOS: as forças de ativação e desativação foram medidas em máquina universal de tração Instron com velocidade de 3mm/minuto e deslocamento de 4mm. Em cada combinação braquete/fio foram executadas oito repetições. A análise estatística empregou ANOVA e o Teste de Comparações Múltiplas de Tukey. RESULTADOS: com 4mm de deformação, as forças médias de ativação foram, em ordem crescente, Damon = 222gf, Easy Clip = 228gf, In-Ovation = 240gf e Smart-Clip = 306gf; a mesma ordem foi observada nas histereses médias, cujos valores foram, respectivamente, 128gf, 140gf, 150gf e 206gf; os valores das forças de desativação foram, respectivamente, 94gf, 88gf, 90gf e 100gf. CONCLUSÃO: os braquetes com maiores valores nas forças de ativação foram acompanhados por maiores valores na histerese, o que resultou em forças de desativação clinicamente semelhantes, independentemente do tipo de braquete autoligável utilizado.
topic Ortodontia corretiva
Fios ortodônticos
Aparelhos ortodônticos
Corrective orthodontics
Orthodontic brackets
Orthodontic wires
url http://www.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512013000100018
work_keys_str_mv AT joserinoneto doesselfligatingbracketstypeinfluencethehysteresisactivationanddeactivationforcesofsuperelasticnitiarchwires
AT gilbertovilanovaqueiroz doesselfligatingbracketstypeinfluencethehysteresisactivationanddeactivationforcesofsuperelasticnitiarchwires
AT joaobatistadepaiva doesselfligatingbracketstypeinfluencethehysteresisactivationanddeactivationforcesofsuperelasticnitiarchwires
AT rafaelyagueballester doesselfligatingbracketstypeinfluencethehysteresisactivationanddeactivationforcesofsuperelasticnitiarchwires
_version_ 1725234192229335040