Optimization of the prescription isodose line for Gamma Knife radiosurgery using the shot within shot technique

Abstract Background This work explores how the choice of prescription isodose line (IDL) affects the dose gradient, target coverage, and treatment time for Gamma Knife radiosurgery when a smaller shot is encompassed within a larger shot at the same stereotactic coordinates (shot within shot techniqu...

Full description

Bibliographic Details
Main Authors: Perry B. Johnson, Maria I. Monterroso, Fei Yang, Eric Mellon
Format: Article
Language:English
Published: BMC 2017-11-01
Series:Radiation Oncology
Subjects:
Online Access:http://link.springer.com/article/10.1186/s13014-017-0919-4
id doaj-6421e05393b045e1a732580276dd92e8
record_format Article
spelling doaj-6421e05393b045e1a732580276dd92e82020-11-24T20:57:44ZengBMCRadiation Oncology1748-717X2017-11-011211910.1186/s13014-017-0919-4Optimization of the prescription isodose line for Gamma Knife radiosurgery using the shot within shot techniquePerry B. Johnson0Maria I. Monterroso1Fei Yang2Eric Mellon3Radiation Oncology / Biomedical Engineering, University of MiamiRadiation Oncology, University of MiamiRadiation Oncology, University of MiamiRadiation Oncology, University of MiamiAbstract Background This work explores how the choice of prescription isodose line (IDL) affects the dose gradient, target coverage, and treatment time for Gamma Knife radiosurgery when a smaller shot is encompassed within a larger shot at the same stereotactic coordinates (shot within shot technique). Methods Beam profiles for the 4, 8, and 16 mm collimator settings were extracted from the treatment planning system and characterized using Gaussian fits. The characterized data were used to create over 10,000 shot within shot configurations by systematically changing collimator weighting and choice of prescription IDL. Each configuration was quantified in terms of the dose gradient, target coverage, and beam-on time. By analyzing these configurations, it was found that there are regions of overlap in target size where a higher prescription IDL provides equivalent dose fall-off to a plan prescribed at the 50% IDL. Furthermore, the data indicate that treatment times within these regions can be reduced by up to 40%. An optimization strategy was devised to realize these gains. The strategy was tested for seven patients treated for 1–4 brain metastases (20 lesions total). Results For a single collimator setting, the gradient in the axial plane was steepest when prescribed to the 56–63% (4 mm), 62–70% (8 mm), and 77–84% (16 mm) IDL, respectively. Through utilization of the optimization technique, beam-on time was reduced by more than 15% in 16/20 lesions. The volume of normal brain receiving 12 Gy or above also decreased in many cases, and in only one instance increased by more than 0.5 cm3. Conclusions This work demonstrates that IDL optimization using the shot within shot technique can reduce treatment times without degrading treatment plan quality.http://link.springer.com/article/10.1186/s13014-017-0919-4RadiosurgeryGamma KnifeGradient indexOptimizationMetastases
collection DOAJ
language English
format Article
sources DOAJ
author Perry B. Johnson
Maria I. Monterroso
Fei Yang
Eric Mellon
spellingShingle Perry B. Johnson
Maria I. Monterroso
Fei Yang
Eric Mellon
Optimization of the prescription isodose line for Gamma Knife radiosurgery using the shot within shot technique
Radiation Oncology
Radiosurgery
Gamma Knife
Gradient index
Optimization
Metastases
author_facet Perry B. Johnson
Maria I. Monterroso
Fei Yang
Eric Mellon
author_sort Perry B. Johnson
title Optimization of the prescription isodose line for Gamma Knife radiosurgery using the shot within shot technique
title_short Optimization of the prescription isodose line for Gamma Knife radiosurgery using the shot within shot technique
title_full Optimization of the prescription isodose line for Gamma Knife radiosurgery using the shot within shot technique
title_fullStr Optimization of the prescription isodose line for Gamma Knife radiosurgery using the shot within shot technique
title_full_unstemmed Optimization of the prescription isodose line for Gamma Knife radiosurgery using the shot within shot technique
title_sort optimization of the prescription isodose line for gamma knife radiosurgery using the shot within shot technique
publisher BMC
series Radiation Oncology
issn 1748-717X
publishDate 2017-11-01
description Abstract Background This work explores how the choice of prescription isodose line (IDL) affects the dose gradient, target coverage, and treatment time for Gamma Knife radiosurgery when a smaller shot is encompassed within a larger shot at the same stereotactic coordinates (shot within shot technique). Methods Beam profiles for the 4, 8, and 16 mm collimator settings were extracted from the treatment planning system and characterized using Gaussian fits. The characterized data were used to create over 10,000 shot within shot configurations by systematically changing collimator weighting and choice of prescription IDL. Each configuration was quantified in terms of the dose gradient, target coverage, and beam-on time. By analyzing these configurations, it was found that there are regions of overlap in target size where a higher prescription IDL provides equivalent dose fall-off to a plan prescribed at the 50% IDL. Furthermore, the data indicate that treatment times within these regions can be reduced by up to 40%. An optimization strategy was devised to realize these gains. The strategy was tested for seven patients treated for 1–4 brain metastases (20 lesions total). Results For a single collimator setting, the gradient in the axial plane was steepest when prescribed to the 56–63% (4 mm), 62–70% (8 mm), and 77–84% (16 mm) IDL, respectively. Through utilization of the optimization technique, beam-on time was reduced by more than 15% in 16/20 lesions. The volume of normal brain receiving 12 Gy or above also decreased in many cases, and in only one instance increased by more than 0.5 cm3. Conclusions This work demonstrates that IDL optimization using the shot within shot technique can reduce treatment times without degrading treatment plan quality.
topic Radiosurgery
Gamma Knife
Gradient index
Optimization
Metastases
url http://link.springer.com/article/10.1186/s13014-017-0919-4
work_keys_str_mv AT perrybjohnson optimizationoftheprescriptionisodoselineforgammakniferadiosurgeryusingtheshotwithinshottechnique
AT mariaimonterroso optimizationoftheprescriptionisodoselineforgammakniferadiosurgeryusingtheshotwithinshottechnique
AT feiyang optimizationoftheprescriptionisodoselineforgammakniferadiosurgeryusingtheshotwithinshottechnique
AT ericmellon optimizationoftheprescriptionisodoselineforgammakniferadiosurgeryusingtheshotwithinshottechnique
_version_ 1716787706880589824