Insertion of a foldable hydrophobic IOL through the trabeculectomy fistula in cases with Microincision cataract surgery combined with trabeculectomy

<p>Abstract</p> <p>Background</p> <p>The use of conventional foldable hydrophobic intraocular lenses (IOLs) in microincision cataract surgery (MICS) currently requires wound enlargement. We describe a combined surgical technique of MICS and trabeculectomy with insertion...

Full description

Bibliographic Details
Main Authors: Sethi Harinder S, Muralidhar Rajamani, Dada Tanuj
Format: Article
Language:English
Published: BMC 2006-03-01
Series:BMC Ophthalmology
Online Access:http://www.biomedcentral.com/1471-2415/6/14
id doaj-64abf0802f264a9eb42628857a0fdba7
record_format Article
spelling doaj-64abf0802f264a9eb42628857a0fdba72020-11-24T23:46:38ZengBMCBMC Ophthalmology1471-24152006-03-01611410.1186/1471-2415-6-14Insertion of a foldable hydrophobic IOL through the trabeculectomy fistula in cases with Microincision cataract surgery combined with trabeculectomySethi Harinder SMuralidhar RajamaniDada Tanuj<p>Abstract</p> <p>Background</p> <p>The use of conventional foldable hydrophobic intraocular lenses (IOLs) in microincision cataract surgery (MICS) currently requires wound enlargement. We describe a combined surgical technique of MICS and trabeculectomy with insertion of a foldable IOL through the trabeculectomy fistula.</p> <p>Methods</p> <p>After completion of MICS through two side port incisions, a 3.2 mm keratome is used to enter the anterior chamber under the previously outlined scleral flap. An Acrysof multi piece IOL (Alcon labs, Fort Worth, Tx) is inserted into the capsular bag through this incision. The scleral flap is then elevated and a 2 × 2 mm fistula made with a Kelly's punch. The scleral flap and conjunctival closure is performed as usual.</p> <p>Results</p> <p>Five patients with primary open angle glaucoma with a visually significant cataract underwent the above mentioned procedure. An IOL was implated in the capsular bag in all cases with no intraperative complications. After surgery, all patients obtained a best corrected visual acuity of 20/20, IOL was well centered at 4 weeks follow up. The mean IOP (without any antiglaucoma medication) was 13.2 + 2.4 mm Hg at 12 weeks with a well formed diffuse filtering bleb in all the cases.</p> <p>Conclusion</p> <p>The technique of combining MICS with trabeculectomy and insertion of a foldable IOL through the trabeculectomy fistula is a feasible and valuable technique for cases which require combined cataract and glaucoma surgery.</p> http://www.biomedcentral.com/1471-2415/6/14
collection DOAJ
language English
format Article
sources DOAJ
author Sethi Harinder S
Muralidhar Rajamani
Dada Tanuj
spellingShingle Sethi Harinder S
Muralidhar Rajamani
Dada Tanuj
Insertion of a foldable hydrophobic IOL through the trabeculectomy fistula in cases with Microincision cataract surgery combined with trabeculectomy
BMC Ophthalmology
author_facet Sethi Harinder S
Muralidhar Rajamani
Dada Tanuj
author_sort Sethi Harinder S
title Insertion of a foldable hydrophobic IOL through the trabeculectomy fistula in cases with Microincision cataract surgery combined with trabeculectomy
title_short Insertion of a foldable hydrophobic IOL through the trabeculectomy fistula in cases with Microincision cataract surgery combined with trabeculectomy
title_full Insertion of a foldable hydrophobic IOL through the trabeculectomy fistula in cases with Microincision cataract surgery combined with trabeculectomy
title_fullStr Insertion of a foldable hydrophobic IOL through the trabeculectomy fistula in cases with Microincision cataract surgery combined with trabeculectomy
title_full_unstemmed Insertion of a foldable hydrophobic IOL through the trabeculectomy fistula in cases with Microincision cataract surgery combined with trabeculectomy
title_sort insertion of a foldable hydrophobic iol through the trabeculectomy fistula in cases with microincision cataract surgery combined with trabeculectomy
publisher BMC
series BMC Ophthalmology
issn 1471-2415
publishDate 2006-03-01
description <p>Abstract</p> <p>Background</p> <p>The use of conventional foldable hydrophobic intraocular lenses (IOLs) in microincision cataract surgery (MICS) currently requires wound enlargement. We describe a combined surgical technique of MICS and trabeculectomy with insertion of a foldable IOL through the trabeculectomy fistula.</p> <p>Methods</p> <p>After completion of MICS through two side port incisions, a 3.2 mm keratome is used to enter the anterior chamber under the previously outlined scleral flap. An Acrysof multi piece IOL (Alcon labs, Fort Worth, Tx) is inserted into the capsular bag through this incision. The scleral flap is then elevated and a 2 × 2 mm fistula made with a Kelly's punch. The scleral flap and conjunctival closure is performed as usual.</p> <p>Results</p> <p>Five patients with primary open angle glaucoma with a visually significant cataract underwent the above mentioned procedure. An IOL was implated in the capsular bag in all cases with no intraperative complications. After surgery, all patients obtained a best corrected visual acuity of 20/20, IOL was well centered at 4 weeks follow up. The mean IOP (without any antiglaucoma medication) was 13.2 + 2.4 mm Hg at 12 weeks with a well formed diffuse filtering bleb in all the cases.</p> <p>Conclusion</p> <p>The technique of combining MICS with trabeculectomy and insertion of a foldable IOL through the trabeculectomy fistula is a feasible and valuable technique for cases which require combined cataract and glaucoma surgery.</p>
url http://www.biomedcentral.com/1471-2415/6/14
work_keys_str_mv AT sethiharinders insertionofafoldablehydrophobiciolthroughthetrabeculectomyfistulaincaseswithmicroincisioncataractsurgerycombinedwithtrabeculectomy
AT muralidharrajamani insertionofafoldablehydrophobiciolthroughthetrabeculectomyfistulaincaseswithmicroincisioncataractsurgerycombinedwithtrabeculectomy
AT dadatanuj insertionofafoldablehydrophobiciolthroughthetrabeculectomyfistulaincaseswithmicroincisioncataractsurgerycombinedwithtrabeculectomy
_version_ 1725493077672460288