Biodistribution and radiation dosimetry of the novel hypoxia PET probe [18F]DiFA and comparison with [18F]FMISO
Abstract Background To facilitate hypoxia imaging in a clinical setting, we developed 1-(2,2-dihydroxymethyl-3-[18F]-fluoropropyl)-2-nitroimidazole ([18F]DiFA) as a new tracer that targets tumor hypoxia with its lower lipophilicity and efficient radiosynthesis. Here, we evaluated the radiation dosag...
Main Authors: | , , , , , , , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
SpringerOpen
2019-07-01
|
Series: | EJNMMI Research |
Subjects: | |
Online Access: | http://link.springer.com/article/10.1186/s13550-019-0525-6 |
id |
doaj-681f36a3288643ba9df1fbbb1bbee786 |
---|---|
record_format |
Article |
spelling |
doaj-681f36a3288643ba9df1fbbb1bbee7862020-11-25T02:50:13ZengSpringerOpenEJNMMI Research2191-219X2019-07-019111110.1186/s13550-019-0525-6Biodistribution and radiation dosimetry of the novel hypoxia PET probe [18F]DiFA and comparison with [18F]FMISOShiro Watanabe0Tohru Shiga1Kenji Hirata2Keiichi Magota3Shozo Okamoto4Takuya Toyonaga5Kei Higashikawa6Hironobu Yasui7Jun Kobayashi8Ken-ichi Nishijima9Ken Iseki10Hiroki Matsumoto11Yuji Kuge12Nagara Tamaki13Department of Nuclear Medicine, Graduate School of Medicine, Hokkaido UniversityDepartment of Nuclear Medicine, Graduate School of Medicine, Hokkaido UniversityDepartment of Nuclear Medicine, Graduate School of Medicine, Hokkaido UniversityDivision of Medical Imaging and Technology, Hokkaido University HospitalDepartment of Nuclear Medicine, Graduate School of Medicine, Hokkaido UniversityDepartment of Nuclear Medicine, Graduate School of Medicine, Hokkaido UniversityCentral Institute of Isotope Science, Hokkaido UniversityCentral Institute of Isotope Science, Hokkaido UniversityDepartment of Pharmacy, Hokkaido University HospitalCentral Institute of Isotope Science, Hokkaido UniversityDepartment of Pharmacy, Hokkaido University HospitalResearch Centre, Nihon Medi-Physics Co., Ltd.Department of Nuclear Medicine, Graduate School of Medicine, Hokkaido UniversityDepartment of Nuclear Medicine, Graduate School of Medicine, Hokkaido UniversityAbstract Background To facilitate hypoxia imaging in a clinical setting, we developed 1-(2,2-dihydroxymethyl-3-[18F]-fluoropropyl)-2-nitroimidazole ([18F]DiFA) as a new tracer that targets tumor hypoxia with its lower lipophilicity and efficient radiosynthesis. Here, we evaluated the radiation dosage, biodistribution, human safety, tolerability, and early elimination after the injection of [18F]DiFA in healthy subjects, and we performed a preliminary clinical study of patients with malignant tumors in a comparison with [18F]fluoromisonidazole ([18F]FMISO). Results The single administration of [18F]DiFA in 8 healthy male adults caused neither adverse events nor abnormal clinical findings. Dynamic and sequential whole-body scans showed that [18F]DiFA was rapidly cleared from all of the organs via the hepatobiliary and urinary systems. The whole-body mean effective dose of [18F]DiFA estimated by using the medical internal radiation dose (MIRD) schema with organ level internal dose assessment/exponential modeling (OLINDA/EXM) computer software 1.1 was 14.4 ± 0.7 μSv/MBq. Among the organs, the urinary bladder received the largest absorbed dose (94.7 ± 13.6 μSv/MBq). The mean absorbed doses of the other organs were equal to or less than those from other hypoxia tracers. The excretion of radioactivity via the urinary system was very rapid, reaching 86.4 ± 7.1% of the administered dose. For the preliminary clinical study, seven patients were subjected to [18F]FMISO and [18F]DiFA positron emission tomography (PET) at 48-h intervals to compare the two tracers’ diagnostic ability for tumor hypoxia. The results of the tumor hypoxia evaluation by [18F]DiFA PET at 1 h and 2 h were not significantly different from those obtained with [18F]FMISO PET at 4 h ([18F]DiFA at 1 h, p = 0.32; [18F]DiFA at 2 h, p = 0.08). Moreover, [18F]DiFA PET at both 1 h (k = 0.68) and 2 h (k = 1.00) showed better inter-observer reproducibility than [18F]FMISO PET at 4 h (k = 0.59). Conclusion [18F]DiFA is well tolerated, and its radiation dose is comparable to those of other hypoxia tracers. [18F]DiFA is very rapidly cleared via the urinary system. [18F]DiFA PET generated comparable images to [18F]FMISO PET in hypoxia imaging with shorter waiting time, demonstrating the promising potential of [18F]DiFA PET for hypoxia imaging and for a multicenter trial.http://link.springer.com/article/10.1186/s13550-019-0525-6HypoxiaPETNew tracerDosimetry |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Shiro Watanabe Tohru Shiga Kenji Hirata Keiichi Magota Shozo Okamoto Takuya Toyonaga Kei Higashikawa Hironobu Yasui Jun Kobayashi Ken-ichi Nishijima Ken Iseki Hiroki Matsumoto Yuji Kuge Nagara Tamaki |
spellingShingle |
Shiro Watanabe Tohru Shiga Kenji Hirata Keiichi Magota Shozo Okamoto Takuya Toyonaga Kei Higashikawa Hironobu Yasui Jun Kobayashi Ken-ichi Nishijima Ken Iseki Hiroki Matsumoto Yuji Kuge Nagara Tamaki Biodistribution and radiation dosimetry of the novel hypoxia PET probe [18F]DiFA and comparison with [18F]FMISO EJNMMI Research Hypoxia PET New tracer Dosimetry |
author_facet |
Shiro Watanabe Tohru Shiga Kenji Hirata Keiichi Magota Shozo Okamoto Takuya Toyonaga Kei Higashikawa Hironobu Yasui Jun Kobayashi Ken-ichi Nishijima Ken Iseki Hiroki Matsumoto Yuji Kuge Nagara Tamaki |
author_sort |
Shiro Watanabe |
title |
Biodistribution and radiation dosimetry of the novel hypoxia PET probe [18F]DiFA and comparison with [18F]FMISO |
title_short |
Biodistribution and radiation dosimetry of the novel hypoxia PET probe [18F]DiFA and comparison with [18F]FMISO |
title_full |
Biodistribution and radiation dosimetry of the novel hypoxia PET probe [18F]DiFA and comparison with [18F]FMISO |
title_fullStr |
Biodistribution and radiation dosimetry of the novel hypoxia PET probe [18F]DiFA and comparison with [18F]FMISO |
title_full_unstemmed |
Biodistribution and radiation dosimetry of the novel hypoxia PET probe [18F]DiFA and comparison with [18F]FMISO |
title_sort |
biodistribution and radiation dosimetry of the novel hypoxia pet probe [18f]difa and comparison with [18f]fmiso |
publisher |
SpringerOpen |
series |
EJNMMI Research |
issn |
2191-219X |
publishDate |
2019-07-01 |
description |
Abstract Background To facilitate hypoxia imaging in a clinical setting, we developed 1-(2,2-dihydroxymethyl-3-[18F]-fluoropropyl)-2-nitroimidazole ([18F]DiFA) as a new tracer that targets tumor hypoxia with its lower lipophilicity and efficient radiosynthesis. Here, we evaluated the radiation dosage, biodistribution, human safety, tolerability, and early elimination after the injection of [18F]DiFA in healthy subjects, and we performed a preliminary clinical study of patients with malignant tumors in a comparison with [18F]fluoromisonidazole ([18F]FMISO). Results The single administration of [18F]DiFA in 8 healthy male adults caused neither adverse events nor abnormal clinical findings. Dynamic and sequential whole-body scans showed that [18F]DiFA was rapidly cleared from all of the organs via the hepatobiliary and urinary systems. The whole-body mean effective dose of [18F]DiFA estimated by using the medical internal radiation dose (MIRD) schema with organ level internal dose assessment/exponential modeling (OLINDA/EXM) computer software 1.1 was 14.4 ± 0.7 μSv/MBq. Among the organs, the urinary bladder received the largest absorbed dose (94.7 ± 13.6 μSv/MBq). The mean absorbed doses of the other organs were equal to or less than those from other hypoxia tracers. The excretion of radioactivity via the urinary system was very rapid, reaching 86.4 ± 7.1% of the administered dose. For the preliminary clinical study, seven patients were subjected to [18F]FMISO and [18F]DiFA positron emission tomography (PET) at 48-h intervals to compare the two tracers’ diagnostic ability for tumor hypoxia. The results of the tumor hypoxia evaluation by [18F]DiFA PET at 1 h and 2 h were not significantly different from those obtained with [18F]FMISO PET at 4 h ([18F]DiFA at 1 h, p = 0.32; [18F]DiFA at 2 h, p = 0.08). Moreover, [18F]DiFA PET at both 1 h (k = 0.68) and 2 h (k = 1.00) showed better inter-observer reproducibility than [18F]FMISO PET at 4 h (k = 0.59). Conclusion [18F]DiFA is well tolerated, and its radiation dose is comparable to those of other hypoxia tracers. [18F]DiFA is very rapidly cleared via the urinary system. [18F]DiFA PET generated comparable images to [18F]FMISO PET in hypoxia imaging with shorter waiting time, demonstrating the promising potential of [18F]DiFA PET for hypoxia imaging and for a multicenter trial. |
topic |
Hypoxia PET New tracer Dosimetry |
url |
http://link.springer.com/article/10.1186/s13550-019-0525-6 |
work_keys_str_mv |
AT shirowatanabe biodistributionandradiationdosimetryofthenovelhypoxiapetprobe18fdifaandcomparisonwith18ffmiso AT tohrushiga biodistributionandradiationdosimetryofthenovelhypoxiapetprobe18fdifaandcomparisonwith18ffmiso AT kenjihirata biodistributionandradiationdosimetryofthenovelhypoxiapetprobe18fdifaandcomparisonwith18ffmiso AT keiichimagota biodistributionandradiationdosimetryofthenovelhypoxiapetprobe18fdifaandcomparisonwith18ffmiso AT shozookamoto biodistributionandradiationdosimetryofthenovelhypoxiapetprobe18fdifaandcomparisonwith18ffmiso AT takuyatoyonaga biodistributionandradiationdosimetryofthenovelhypoxiapetprobe18fdifaandcomparisonwith18ffmiso AT keihigashikawa biodistributionandradiationdosimetryofthenovelhypoxiapetprobe18fdifaandcomparisonwith18ffmiso AT hironobuyasui biodistributionandradiationdosimetryofthenovelhypoxiapetprobe18fdifaandcomparisonwith18ffmiso AT junkobayashi biodistributionandradiationdosimetryofthenovelhypoxiapetprobe18fdifaandcomparisonwith18ffmiso AT kenichinishijima biodistributionandradiationdosimetryofthenovelhypoxiapetprobe18fdifaandcomparisonwith18ffmiso AT keniseki biodistributionandradiationdosimetryofthenovelhypoxiapetprobe18fdifaandcomparisonwith18ffmiso AT hirokimatsumoto biodistributionandradiationdosimetryofthenovelhypoxiapetprobe18fdifaandcomparisonwith18ffmiso AT yujikuge biodistributionandradiationdosimetryofthenovelhypoxiapetprobe18fdifaandcomparisonwith18ffmiso AT nagaratamaki biodistributionandradiationdosimetryofthenovelhypoxiapetprobe18fdifaandcomparisonwith18ffmiso |
_version_ |
1724739133605150720 |