Zotarolimus-eluting stent fracture at initial implantation diagnosed with StentBoost

Stent fracture is a rare complication of drug-eluting stent implantation with a reported rate of 0.84%–3.2% in various clinical studies with first-generation drug-eluting stents and 29% in autopsy studies. Sirolimus-eluting stents with their closed cell design were reported to be more prone to fract...

Full description

Bibliographic Details
Main Authors: Alev Arat Ozkan, Umit Yasar Sinan, Aziz T Gurmen
Format: Article
Language:English
Published: SAGE Publishing 2016-05-01
Series:SAGE Open Medical Case Reports
Online Access:https://doi.org/10.1177/2050313X16645754
id doaj-6c7cd837fb664ab5858140dc67c7d82d
record_format Article
spelling doaj-6c7cd837fb664ab5858140dc67c7d82d2020-11-25T02:34:07ZengSAGE PublishingSAGE Open Medical Case Reports2050-313X2016-05-01410.1177/2050313X1664575410.1177_2050313X16645754Zotarolimus-eluting stent fracture at initial implantation diagnosed with StentBoostAlev Arat OzkanUmit Yasar SinanAziz T GurmenStent fracture is a rare complication of drug-eluting stent implantation with a reported rate of 0.84%–3.2% in various clinical studies with first-generation drug-eluting stents and 29% in autopsy studies. Sirolimus-eluting stents with their closed cell design were reported to be more prone to fracture compared to paclitaxel-eluting stents. Other risk factors for stent fracture are multiple stenting, longer stent length, chronic renal failure, right coronary artery intervention, and a higher maximal inflation pressure. The role of angiography in diagnosing stent fracture is limited, a fact also questioning the reliability of angiographic data. Image enhancement techniques like StentBoost are widely available in new-generation angiography systems and are used to assess stent expansion, overlap size, or to localize the postdilation balloon. Here, we report a case of zotarolimus-eluting stent fracture at initial implantation diagnosed with StentBoost.https://doi.org/10.1177/2050313X16645754
collection DOAJ
language English
format Article
sources DOAJ
author Alev Arat Ozkan
Umit Yasar Sinan
Aziz T Gurmen
spellingShingle Alev Arat Ozkan
Umit Yasar Sinan
Aziz T Gurmen
Zotarolimus-eluting stent fracture at initial implantation diagnosed with StentBoost
SAGE Open Medical Case Reports
author_facet Alev Arat Ozkan
Umit Yasar Sinan
Aziz T Gurmen
author_sort Alev Arat Ozkan
title Zotarolimus-eluting stent fracture at initial implantation diagnosed with StentBoost
title_short Zotarolimus-eluting stent fracture at initial implantation diagnosed with StentBoost
title_full Zotarolimus-eluting stent fracture at initial implantation diagnosed with StentBoost
title_fullStr Zotarolimus-eluting stent fracture at initial implantation diagnosed with StentBoost
title_full_unstemmed Zotarolimus-eluting stent fracture at initial implantation diagnosed with StentBoost
title_sort zotarolimus-eluting stent fracture at initial implantation diagnosed with stentboost
publisher SAGE Publishing
series SAGE Open Medical Case Reports
issn 2050-313X
publishDate 2016-05-01
description Stent fracture is a rare complication of drug-eluting stent implantation with a reported rate of 0.84%–3.2% in various clinical studies with first-generation drug-eluting stents and 29% in autopsy studies. Sirolimus-eluting stents with their closed cell design were reported to be more prone to fracture compared to paclitaxel-eluting stents. Other risk factors for stent fracture are multiple stenting, longer stent length, chronic renal failure, right coronary artery intervention, and a higher maximal inflation pressure. The role of angiography in diagnosing stent fracture is limited, a fact also questioning the reliability of angiographic data. Image enhancement techniques like StentBoost are widely available in new-generation angiography systems and are used to assess stent expansion, overlap size, or to localize the postdilation balloon. Here, we report a case of zotarolimus-eluting stent fracture at initial implantation diagnosed with StentBoost.
url https://doi.org/10.1177/2050313X16645754
work_keys_str_mv AT alevaratozkan zotarolimuselutingstentfractureatinitialimplantationdiagnosedwithstentboost
AT umityasarsinan zotarolimuselutingstentfractureatinitialimplantationdiagnosedwithstentboost
AT aziztgurmen zotarolimuselutingstentfractureatinitialimplantationdiagnosedwithstentboost
_version_ 1724810015343116288