Iatrogenic Left Main Bronchus Injury following Atraumatic Double Lumen Endotracheal Tube Placement

Tracheobronchial disruption is an uncommon but severe complication of double lumen endotracheal tube placement. The physical properties of a double lumen tube (large external diameter and length) make tracheobronchial injury more common than that associated with smaller single lumen endotracheal tu...

Full description

Bibliographic Details
Main Authors: William R. Hartman, Michael Brown, James Hannon
Format: Article
Language:English
Published: Hindawi Limited 2013-01-01
Series:Case Reports in Anesthesiology
Online Access:http://dx.doi.org/10.1155/2013/524348
Description
Summary:Tracheobronchial disruption is an uncommon but severe complication of double lumen endotracheal tube placement. The physical properties of a double lumen tube (large external diameter and length) make tracheobronchial injury more common than that associated with smaller single lumen endotracheal tubes. Here we present the case of an iatrogenic left main bronchus injury caused by placement of a double lumen tube in an otherwise unremarkable airway.
ISSN:2090-6382