Designing a Heart Rate and Body Temperature Measurement Tool Using Pulse Sensor and IR MLX90614 Based on ATmega328 and GSM Technology

The measurement of heart rate and body temperature are two of the five Vital Signs that indicate human health. During this time the heart rate is measured using a stethoscope or counting the heart rate through the wrist but this can cause a Human Error. So a tool is designed that can measure heart r...

Full description

Bibliographic Details
Main Authors: Husnul Hatimah, A. A. Ngurah Gunawan, Ida Bagus Alit Paramarta
Format: Article
Language:English
Published: Universitas Udayana 2018-12-01
Series:Buletin Fisika
Online Access:https://ojs.unud.ac.id/index.php/buletinfisika/article/view/43540
id doaj-700650109d83465b843cdceca7bf5d68
record_format Article
spelling doaj-700650109d83465b843cdceca7bf5d682021-04-02T14:06:26ZengUniversitas UdayanaBuletin Fisika1411-46902580-97332018-12-01192808410.24843/BF.2018.v19.i02.p0743540Designing a Heart Rate and Body Temperature Measurement Tool Using Pulse Sensor and IR MLX90614 Based on ATmega328 and GSM TechnologyHusnul Hatimah0A. A. Ngurah Gunawan1Ida Bagus Alit Paramarta2Fakultas MIPAUdayana UniversityUdayana UniversityThe measurement of heart rate and body temperature are two of the five Vital Signs that indicate human health. During this time the heart rate is measured using a stethoscope or counting the heart rate through the wrist but this can cause a Human Error. So a tool is designed that can measure heart rate and body temperature using pulse sensor and IR MLX90614 besed on ATmega328 which results can be displayed through the website with patients having their own ID so that the data is not mixed with other patient data and equipped with a database so that it can store patient data. From the results of trials on 3 subjects classified according to the age of 5, 9 and 23 years. The average accuracy of heart rate and body temperature measurements between the design tools and standard equipment is 98.54% for heart rate and 95.97% for body temperature.https://ojs.unud.ac.id/index.php/buletinfisika/article/view/43540
collection DOAJ
language English
format Article
sources DOAJ
author Husnul Hatimah
A. A. Ngurah Gunawan
Ida Bagus Alit Paramarta
spellingShingle Husnul Hatimah
A. A. Ngurah Gunawan
Ida Bagus Alit Paramarta
Designing a Heart Rate and Body Temperature Measurement Tool Using Pulse Sensor and IR MLX90614 Based on ATmega328 and GSM Technology
Buletin Fisika
author_facet Husnul Hatimah
A. A. Ngurah Gunawan
Ida Bagus Alit Paramarta
author_sort Husnul Hatimah
title Designing a Heart Rate and Body Temperature Measurement Tool Using Pulse Sensor and IR MLX90614 Based on ATmega328 and GSM Technology
title_short Designing a Heart Rate and Body Temperature Measurement Tool Using Pulse Sensor and IR MLX90614 Based on ATmega328 and GSM Technology
title_full Designing a Heart Rate and Body Temperature Measurement Tool Using Pulse Sensor and IR MLX90614 Based on ATmega328 and GSM Technology
title_fullStr Designing a Heart Rate and Body Temperature Measurement Tool Using Pulse Sensor and IR MLX90614 Based on ATmega328 and GSM Technology
title_full_unstemmed Designing a Heart Rate and Body Temperature Measurement Tool Using Pulse Sensor and IR MLX90614 Based on ATmega328 and GSM Technology
title_sort designing a heart rate and body temperature measurement tool using pulse sensor and ir mlx90614 based on atmega328 and gsm technology
publisher Universitas Udayana
series Buletin Fisika
issn 1411-4690
2580-9733
publishDate 2018-12-01
description The measurement of heart rate and body temperature are two of the five Vital Signs that indicate human health. During this time the heart rate is measured using a stethoscope or counting the heart rate through the wrist but this can cause a Human Error. So a tool is designed that can measure heart rate and body temperature using pulse sensor and IR MLX90614 besed on ATmega328 which results can be displayed through the website with patients having their own ID so that the data is not mixed with other patient data and equipped with a database so that it can store patient data. From the results of trials on 3 subjects classified according to the age of 5, 9 and 23 years. The average accuracy of heart rate and body temperature measurements between the design tools and standard equipment is 98.54% for heart rate and 95.97% for body temperature.
url https://ojs.unud.ac.id/index.php/buletinfisika/article/view/43540
work_keys_str_mv AT husnulhatimah designingaheartrateandbodytemperaturemeasurementtoolusingpulsesensorandirmlx90614basedonatmega328andgsmtechnology
AT aangurahgunawan designingaheartrateandbodytemperaturemeasurementtoolusingpulsesensorandirmlx90614basedonatmega328andgsmtechnology
AT idabagusalitparamarta designingaheartrateandbodytemperaturemeasurementtoolusingpulsesensorandirmlx90614basedonatmega328andgsmtechnology
_version_ 1721563168720814080