Designing a Heart Rate and Body Temperature Measurement Tool Using Pulse Sensor and IR MLX90614 Based on ATmega328 and GSM Technology
The measurement of heart rate and body temperature are two of the five Vital Signs that indicate human health. During this time the heart rate is measured using a stethoscope or counting the heart rate through the wrist but this can cause a Human Error. So a tool is designed that can measure heart r...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Universitas Udayana
2018-12-01
|
Series: | Buletin Fisika |
Online Access: | https://ojs.unud.ac.id/index.php/buletinfisika/article/view/43540 |
id |
doaj-700650109d83465b843cdceca7bf5d68 |
---|---|
record_format |
Article |
spelling |
doaj-700650109d83465b843cdceca7bf5d682021-04-02T14:06:26ZengUniversitas UdayanaBuletin Fisika1411-46902580-97332018-12-01192808410.24843/BF.2018.v19.i02.p0743540Designing a Heart Rate and Body Temperature Measurement Tool Using Pulse Sensor and IR MLX90614 Based on ATmega328 and GSM TechnologyHusnul Hatimah0A. A. Ngurah Gunawan1Ida Bagus Alit Paramarta2Fakultas MIPAUdayana UniversityUdayana UniversityThe measurement of heart rate and body temperature are two of the five Vital Signs that indicate human health. During this time the heart rate is measured using a stethoscope or counting the heart rate through the wrist but this can cause a Human Error. So a tool is designed that can measure heart rate and body temperature using pulse sensor and IR MLX90614 besed on ATmega328 which results can be displayed through the website with patients having their own ID so that the data is not mixed with other patient data and equipped with a database so that it can store patient data. From the results of trials on 3 subjects classified according to the age of 5, 9 and 23 years. The average accuracy of heart rate and body temperature measurements between the design tools and standard equipment is 98.54% for heart rate and 95.97% for body temperature.https://ojs.unud.ac.id/index.php/buletinfisika/article/view/43540 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Husnul Hatimah A. A. Ngurah Gunawan Ida Bagus Alit Paramarta |
spellingShingle |
Husnul Hatimah A. A. Ngurah Gunawan Ida Bagus Alit Paramarta Designing a Heart Rate and Body Temperature Measurement Tool Using Pulse Sensor and IR MLX90614 Based on ATmega328 and GSM Technology Buletin Fisika |
author_facet |
Husnul Hatimah A. A. Ngurah Gunawan Ida Bagus Alit Paramarta |
author_sort |
Husnul Hatimah |
title |
Designing a Heart Rate and Body Temperature Measurement Tool Using Pulse Sensor and IR MLX90614 Based on ATmega328 and GSM Technology |
title_short |
Designing a Heart Rate and Body Temperature Measurement Tool Using Pulse Sensor and IR MLX90614 Based on ATmega328 and GSM Technology |
title_full |
Designing a Heart Rate and Body Temperature Measurement Tool Using Pulse Sensor and IR MLX90614 Based on ATmega328 and GSM Technology |
title_fullStr |
Designing a Heart Rate and Body Temperature Measurement Tool Using Pulse Sensor and IR MLX90614 Based on ATmega328 and GSM Technology |
title_full_unstemmed |
Designing a Heart Rate and Body Temperature Measurement Tool Using Pulse Sensor and IR MLX90614 Based on ATmega328 and GSM Technology |
title_sort |
designing a heart rate and body temperature measurement tool using pulse sensor and ir mlx90614 based on atmega328 and gsm technology |
publisher |
Universitas Udayana |
series |
Buletin Fisika |
issn |
1411-4690 2580-9733 |
publishDate |
2018-12-01 |
description |
The measurement of heart rate and body temperature are two of the five Vital Signs that indicate human health. During this time the heart rate is measured using a stethoscope or counting the heart rate through the wrist but this can cause a Human Error. So a tool is designed that can measure heart rate and body temperature using pulse sensor and IR MLX90614 besed on ATmega328 which results can be displayed through the website with patients having their own ID so that the data is not mixed with other patient data and equipped with a database so that it can store patient data. From the results of trials on 3 subjects classified according to the age of 5, 9 and 23 years. The average accuracy of heart rate and body temperature measurements between the design tools and standard equipment is 98.54% for heart rate and 95.97% for body temperature. |
url |
https://ojs.unud.ac.id/index.php/buletinfisika/article/view/43540 |
work_keys_str_mv |
AT husnulhatimah designingaheartrateandbodytemperaturemeasurementtoolusingpulsesensorandirmlx90614basedonatmega328andgsmtechnology AT aangurahgunawan designingaheartrateandbodytemperaturemeasurementtoolusingpulsesensorandirmlx90614basedonatmega328andgsmtechnology AT idabagusalitparamarta designingaheartrateandbodytemperaturemeasurementtoolusingpulsesensorandirmlx90614basedonatmega328andgsmtechnology |
_version_ |
1721563168720814080 |