Measurements and evaluation of some electrolytes concentrations in spleens of imported sheep to Sulaimani province
The aim of this study was to determine the correlation between some biometrical measurements (length and width) and some electrolytic concentration (Na <sup>+</sup>, K<sup>+</sup> and Cl<sup>-</sup>) in sheep spleen. This study was conducted on 19 spleens of male...
Main Authors: | , |
---|---|
Format: | Article |
Language: | Arabic |
Published: |
University of Mosul, College of Veterinary Medicine
2019-09-01
|
Series: | Iraqi Journal of Veterinary Sciences |
Subjects: | |
Online Access: | https://vetmedmosul.com/article_163168_b426094c096aaa6d382a21c50f6661af.pdf |
id |
doaj-7028d236b94346448231eb651f0f528c |
---|---|
record_format |
Article |
spelling |
doaj-7028d236b94346448231eb651f0f528c2020-11-25T01:31:23ZaraUniversity of Mosul, College of Veterinary MedicineIraqi Journal of Veterinary Sciences1607-38942071-12552019-09-0133241541810.33899/ijvs.2019.163168163168Measurements and evaluation of some electrolytes concentrations in spleens of imported sheep to Sulaimani provinceElham Husain0K.A. Muhammad1Iraq, IraqDepartment of Animal Science, College of Agricultural Science, University of Sulaimani, IraqThe aim of this study was to determine the correlation between some biometrical measurements (length and width) and some electrolytic concentration (Na <sup>+</sup>, K<sup>+</sup> and Cl<sup>-</sup>) in sheep spleen. This study was conducted on 19 spleens of male sheep, they were imported from Syria to Sulaimani province, aged between less than 1 year to 1.5 year. The results showed that the mean values of weight were 108 gm and mean values of length and width of the spleens were 13.72 cm and 9.05 cm, respectively. Also, the mean values of Cl<sup>-</sup>, Na<sup>+ </sup>and K<sup>+</sup> concentration were 14.17 mmol/L, 6.58 mmol/L, 32.89 mmol/L, respectively. The correlation coefficient between weight and width was (r = 0.661, P=0.002) was a higher correlation with R<sup>2</sup> = 0.437. Also It was (r= 0.932, P≤0.0001) between Na<sup>+</sup> and K<sup>+</sup> which was a high correlation, with the higher value of R<sup>2 </sup>=0.869. The results showed the negative correlation between weight and Na<sup>+</sup>, weight and K<sup>+ </sup>with (r= -0.161, P=0.509) and (r= -0.214, P=0.379), respectively. However, it showed the positive correlation between other parameters; weight, length, width , Na<sup>+</sup>, K<sup>+</sup> and Cl<sup>-</sup>, the correlation coefficient (r= 0.421, P= 0.072) between width and Cl<sup>-</sup> was the highest correlation, and the value R<sup>2</sup> = 0.177. In conclusion, our study shows the positive correlation between some parameters (weight, length and width) and some electrolytes concentration (Na<sup>+</sup>, K<sup>+</sup> and Cl<sup>-</sup>) and the highest correlation between width and Cl<sup>-</sup>, however there was a negative correlation between weight and Na<sup>+</sup> and between weight and K<sup>+</sup> in sheep spleen.https://vetmedmosul.com/article_163168_b426094c096aaa6d382a21c50f6661af.pdfspleenbiometrical parameterelectrolytessheep |
collection |
DOAJ |
language |
Arabic |
format |
Article |
sources |
DOAJ |
author |
Elham Husain K.A. Muhammad |
spellingShingle |
Elham Husain K.A. Muhammad Measurements and evaluation of some electrolytes concentrations in spleens of imported sheep to Sulaimani province Iraqi Journal of Veterinary Sciences spleen biometrical parameter electrolytes sheep |
author_facet |
Elham Husain K.A. Muhammad |
author_sort |
Elham Husain |
title |
Measurements and evaluation of some electrolytes concentrations in spleens of imported sheep to Sulaimani province |
title_short |
Measurements and evaluation of some electrolytes concentrations in spleens of imported sheep to Sulaimani province |
title_full |
Measurements and evaluation of some electrolytes concentrations in spleens of imported sheep to Sulaimani province |
title_fullStr |
Measurements and evaluation of some electrolytes concentrations in spleens of imported sheep to Sulaimani province |
title_full_unstemmed |
Measurements and evaluation of some electrolytes concentrations in spleens of imported sheep to Sulaimani province |
title_sort |
measurements and evaluation of some electrolytes concentrations in spleens of imported sheep to sulaimani province |
publisher |
University of Mosul, College of Veterinary Medicine |
series |
Iraqi Journal of Veterinary Sciences |
issn |
1607-3894 2071-1255 |
publishDate |
2019-09-01 |
description |
The aim of this study was to determine the correlation between some biometrical measurements (length and width) and some electrolytic concentration (Na <sup>+</sup>, K<sup>+</sup> and Cl<sup>-</sup>) in sheep spleen. This study was conducted on 19 spleens of male sheep, they were imported from Syria to Sulaimani province, aged between less than 1 year to 1.5 year. The results showed that the mean values of weight were 108 gm and mean values of length and width of the spleens were 13.72 cm and 9.05 cm, respectively. Also, the mean values of Cl<sup>-</sup>, Na<sup>+ </sup>and K<sup>+</sup> concentration were 14.17 mmol/L, 6.58 mmol/L, 32.89 mmol/L, respectively. The correlation coefficient between weight and width was (r = 0.661, P=0.002) was a higher correlation with R<sup>2</sup> = 0.437. Also It was (r= 0.932, P≤0.0001) between Na<sup>+</sup> and K<sup>+</sup> which was a high correlation, with the higher value of R<sup>2 </sup>=0.869. The results showed the negative correlation between weight and Na<sup>+</sup>, weight and K<sup>+ </sup>with (r= -0.161, P=0.509) and (r= -0.214, P=0.379), respectively. However, it showed the positive correlation between other parameters; weight, length, width , Na<sup>+</sup>, K<sup>+</sup> and Cl<sup>-</sup>, the correlation coefficient (r= 0.421, P= 0.072) between width and Cl<sup>-</sup> was the highest correlation, and the value R<sup>2</sup> = 0.177. In conclusion, our study shows the positive correlation between some parameters (weight, length and width) and some electrolytes concentration (Na<sup>+</sup>, K<sup>+</sup> and Cl<sup>-</sup>) and the highest correlation between width and Cl<sup>-</sup>, however there was a negative correlation between weight and Na<sup>+</sup> and between weight and K<sup>+</sup> in sheep spleen. |
topic |
spleen biometrical parameter electrolytes sheep |
url |
https://vetmedmosul.com/article_163168_b426094c096aaa6d382a21c50f6661af.pdf |
work_keys_str_mv |
AT elhamhusain measurementsandevaluationofsomeelectrolytesconcentrationsinspleensofimportedsheeptosulaimaniprovince AT kamuhammad measurementsandevaluationofsomeelectrolytesconcentrationsinspleensofimportedsheeptosulaimaniprovince |
_version_ |
1725086984571977728 |