Radiometric cross Calibration of Gaofen-1 WFV Cameras Using Landsat-8 OLI Images: A Simple Image-Based Method

WFV (Wide Field of View) cameras on-board Gaofen-1 satellite (gaofen means high resolution) provide unparalleled global observations with both high spatial and high temporal resolutions. However, the accuracy of the radiometric calibration remains unknown. Using an improved cross calibration method,...

Full description

Bibliographic Details
Main Authors: Juan Li, Lian Feng, Xiaoping Pang, Weishu Gong, Xi Zhao
Format: Article
Language:English
Published: MDPI AG 2016-05-01
Series:Remote Sensing
Subjects:
Online Access:http://www.mdpi.com/2072-4292/8/5/411
id doaj-72db0e96c09f4e40a1797836c32fdae2
record_format Article
spelling doaj-72db0e96c09f4e40a1797836c32fdae22020-11-24T21:36:42ZengMDPI AGRemote Sensing2072-42922016-05-018541110.3390/rs8050411rs8050411Radiometric cross Calibration of Gaofen-1 WFV Cameras Using Landsat-8 OLI Images: A Simple Image-Based MethodJuan Li0Lian Feng1Xiaoping Pang2Weishu Gong3Xi Zhao4Chinese Antarctic Center of Surveying and Mapping, Wuhan University, Wuhan 430079, ChinaState Key Laboratory of Information Engineering in Surveying, Mapping and Remote Sensing, Wuhan University, Wuhan 430079, ChinaChinese Antarctic Center of Surveying and Mapping, Wuhan University, Wuhan 430079, ChinaDepartment of Geographical Sciences, University of Maryland, College Park, MD 20742, USAChinese Antarctic Center of Surveying and Mapping, Wuhan University, Wuhan 430079, ChinaWFV (Wide Field of View) cameras on-board Gaofen-1 satellite (gaofen means high resolution) provide unparalleled global observations with both high spatial and high temporal resolutions. However, the accuracy of the radiometric calibration remains unknown. Using an improved cross calibration method, the WFV cameras were re-calibrated with well-calibrated Landsat-8 OLI (Operational Land Imager) data as reference. An objective method was proposed to guarantee the homogeneity and sufficient dynamic coverage for calibration sites and reference sensors. The USGS spectral library was used to match the most appropriate hyperspectral data, based on which the spectral band differences between WFV and OLI were adjusted. The TOA (top-of-atmosphere) reflectance of the cross-calibrated WFV agreed very well with that of OLI, with the mean differences between the two sensors less than 5% for most of the reflectance ranges of the four spectral bands, after accounting for the spectral band difference between the two sensors. Given the calibration error of 3% for Landsat-8 OLI TOA reflectance, the uncertainty of the newly-calibrated WFV should be within 8%. The newly generated calibration coefficients established confidence when using Gaofen-1 WFV observations for their further quantitative applications, and the proposed simple cross calibration method here could be easily extended to other operational or planned satellite missions.http://www.mdpi.com/2072-4292/8/5/411cross calibrationGaofen-1 WFVLandsat-8 OLIrelative spectral responsespectral libraryremote sensing
collection DOAJ
language English
format Article
sources DOAJ
author Juan Li
Lian Feng
Xiaoping Pang
Weishu Gong
Xi Zhao
spellingShingle Juan Li
Lian Feng
Xiaoping Pang
Weishu Gong
Xi Zhao
Radiometric cross Calibration of Gaofen-1 WFV Cameras Using Landsat-8 OLI Images: A Simple Image-Based Method
Remote Sensing
cross calibration
Gaofen-1 WFV
Landsat-8 OLI
relative spectral response
spectral library
remote sensing
author_facet Juan Li
Lian Feng
Xiaoping Pang
Weishu Gong
Xi Zhao
author_sort Juan Li
title Radiometric cross Calibration of Gaofen-1 WFV Cameras Using Landsat-8 OLI Images: A Simple Image-Based Method
title_short Radiometric cross Calibration of Gaofen-1 WFV Cameras Using Landsat-8 OLI Images: A Simple Image-Based Method
title_full Radiometric cross Calibration of Gaofen-1 WFV Cameras Using Landsat-8 OLI Images: A Simple Image-Based Method
title_fullStr Radiometric cross Calibration of Gaofen-1 WFV Cameras Using Landsat-8 OLI Images: A Simple Image-Based Method
title_full_unstemmed Radiometric cross Calibration of Gaofen-1 WFV Cameras Using Landsat-8 OLI Images: A Simple Image-Based Method
title_sort radiometric cross calibration of gaofen-1 wfv cameras using landsat-8 oli images: a simple image-based method
publisher MDPI AG
series Remote Sensing
issn 2072-4292
publishDate 2016-05-01
description WFV (Wide Field of View) cameras on-board Gaofen-1 satellite (gaofen means high resolution) provide unparalleled global observations with both high spatial and high temporal resolutions. However, the accuracy of the radiometric calibration remains unknown. Using an improved cross calibration method, the WFV cameras were re-calibrated with well-calibrated Landsat-8 OLI (Operational Land Imager) data as reference. An objective method was proposed to guarantee the homogeneity and sufficient dynamic coverage for calibration sites and reference sensors. The USGS spectral library was used to match the most appropriate hyperspectral data, based on which the spectral band differences between WFV and OLI were adjusted. The TOA (top-of-atmosphere) reflectance of the cross-calibrated WFV agreed very well with that of OLI, with the mean differences between the two sensors less than 5% for most of the reflectance ranges of the four spectral bands, after accounting for the spectral band difference between the two sensors. Given the calibration error of 3% for Landsat-8 OLI TOA reflectance, the uncertainty of the newly-calibrated WFV should be within 8%. The newly generated calibration coefficients established confidence when using Gaofen-1 WFV observations for their further quantitative applications, and the proposed simple cross calibration method here could be easily extended to other operational or planned satellite missions.
topic cross calibration
Gaofen-1 WFV
Landsat-8 OLI
relative spectral response
spectral library
remote sensing
url http://www.mdpi.com/2072-4292/8/5/411
work_keys_str_mv AT juanli radiometriccrosscalibrationofgaofen1wfvcamerasusinglandsat8oliimagesasimpleimagebasedmethod
AT lianfeng radiometriccrosscalibrationofgaofen1wfvcamerasusinglandsat8oliimagesasimpleimagebasedmethod
AT xiaopingpang radiometriccrosscalibrationofgaofen1wfvcamerasusinglandsat8oliimagesasimpleimagebasedmethod
AT weishugong radiometriccrosscalibrationofgaofen1wfvcamerasusinglandsat8oliimagesasimpleimagebasedmethod
AT xizhao radiometriccrosscalibrationofgaofen1wfvcamerasusinglandsat8oliimagesasimpleimagebasedmethod
_version_ 1725939861971533824