Influence of balloon pressure inflation in patients undergoing primary coronary stent implantation during acute myocardial infarction: a quantitative coronary angiography analysis

OBJECTIVE:To verify the influence of moderate- or high-pressure balloon inflation during primary coronary stent implantation for acute myocardial infarction. METHODS: After successful coronary stent implantation, 82 patients were divided into 2 groups according to the last balloon inflation pressure...

Full description

Bibliographic Details
Main Authors: Luiz Alberto Mattos, Amanda G.M.R. Sousa, Áurea Chaves, Fausto Feres, Ibraim Pinto, Luiz Tanajura, Marinella Centemero, Alexandre Abizaid, Ana C. Seixas, Andréa Abizaid, Galo Maldonado, Rodolfo Staico, J. Eduardo M.R. Sousa
Format: Article
Language:English
Published: Sociedade Brasileira de Cardiologia (SBC) 2003-03-01
Series:Arquivos Brasileiros de Cardiologia
Subjects:
Online Access:http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0066-782X2003000300002
id doaj-7332f72339cd41d097c98268c2a090e8
record_format Article
spelling doaj-7332f72339cd41d097c98268c2a090e82020-11-24T23:16:30ZengSociedade Brasileira de Cardiologia (SBC)Arquivos Brasileiros de Cardiologia0066-782X1678-41702003-03-0180326026810.1590/S0066-782X2003000300002Influence of balloon pressure inflation in patients undergoing primary coronary stent implantation during acute myocardial infarction: a quantitative coronary angiography analysisLuiz Alberto MattosAmanda G.M.R. SousaÁurea ChavesFausto FeresIbraim PintoLuiz TanajuraMarinella CentemeroAlexandre AbizaidAna C. SeixasAndréa AbizaidGalo MaldonadoRodolfo StaicoJ. Eduardo M.R. SousaOBJECTIVE:To verify the influence of moderate- or high-pressure balloon inflation during primary coronary stent implantation for acute myocardial infarction. METHODS: After successful coronary stent implantation, 82 patients were divided into 2 groups according to the last balloon inflation pressure: group 1 (<FONT FACE=Symbol>&sup3;</FONT>12 to <16 atm) and group 2 (<FONT FACE=Symbol>&sup3;</FONT>16 to 20 atm), each with 41 cases. All patients underwent late coronary angiography. RESULTS: In group 1, the mean stent deployment pressure was 13.58±0.92 atm, and in the group 2 it was 18.15±1.66 atm. Stents implanted with moderate pressures (<FONT FACE=Symbol>&sup3;</FONT>12 to <16 atm) had a significantly smaller postprocedural minimal lumen diameter, compared to with those with higher pressure, with lesser acute gain (2.7± 0.4 mm vs 2.9±04 mm; p=0.004), but the late lumen loss (0,9±0,8 mm vs 0,9±0,6 mm) and the restenosis (22% vs. 17.1%) and target-vessel revascularization rates (9.8% vs 7.3%) were similar between the groups. CONCLUSION: During AMI stenting, the use of high pressures (<FONT FACE=Symbol>&sup3;</FONT>16 atm) did not cause a measurable improvement in late outcome, either in the late loss, its index, and the net gain, or in clinical and angiographic restenosis rates.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0066-782X2003000300002acute myocardial infarctionstentsrestenosis
collection DOAJ
language English
format Article
sources DOAJ
author Luiz Alberto Mattos
Amanda G.M.R. Sousa
Áurea Chaves
Fausto Feres
Ibraim Pinto
Luiz Tanajura
Marinella Centemero
Alexandre Abizaid
Ana C. Seixas
Andréa Abizaid
Galo Maldonado
Rodolfo Staico
J. Eduardo M.R. Sousa
spellingShingle Luiz Alberto Mattos
Amanda G.M.R. Sousa
Áurea Chaves
Fausto Feres
Ibraim Pinto
Luiz Tanajura
Marinella Centemero
Alexandre Abizaid
Ana C. Seixas
Andréa Abizaid
Galo Maldonado
Rodolfo Staico
J. Eduardo M.R. Sousa
Influence of balloon pressure inflation in patients undergoing primary coronary stent implantation during acute myocardial infarction: a quantitative coronary angiography analysis
Arquivos Brasileiros de Cardiologia
acute myocardial infarction
stents
restenosis
author_facet Luiz Alberto Mattos
Amanda G.M.R. Sousa
Áurea Chaves
Fausto Feres
Ibraim Pinto
Luiz Tanajura
Marinella Centemero
Alexandre Abizaid
Ana C. Seixas
Andréa Abizaid
Galo Maldonado
Rodolfo Staico
J. Eduardo M.R. Sousa
author_sort Luiz Alberto Mattos
title Influence of balloon pressure inflation in patients undergoing primary coronary stent implantation during acute myocardial infarction: a quantitative coronary angiography analysis
title_short Influence of balloon pressure inflation in patients undergoing primary coronary stent implantation during acute myocardial infarction: a quantitative coronary angiography analysis
title_full Influence of balloon pressure inflation in patients undergoing primary coronary stent implantation during acute myocardial infarction: a quantitative coronary angiography analysis
title_fullStr Influence of balloon pressure inflation in patients undergoing primary coronary stent implantation during acute myocardial infarction: a quantitative coronary angiography analysis
title_full_unstemmed Influence of balloon pressure inflation in patients undergoing primary coronary stent implantation during acute myocardial infarction: a quantitative coronary angiography analysis
title_sort influence of balloon pressure inflation in patients undergoing primary coronary stent implantation during acute myocardial infarction: a quantitative coronary angiography analysis
publisher Sociedade Brasileira de Cardiologia (SBC)
series Arquivos Brasileiros de Cardiologia
issn 0066-782X
1678-4170
publishDate 2003-03-01
description OBJECTIVE:To verify the influence of moderate- or high-pressure balloon inflation during primary coronary stent implantation for acute myocardial infarction. METHODS: After successful coronary stent implantation, 82 patients were divided into 2 groups according to the last balloon inflation pressure: group 1 (<FONT FACE=Symbol>&sup3;</FONT>12 to <16 atm) and group 2 (<FONT FACE=Symbol>&sup3;</FONT>16 to 20 atm), each with 41 cases. All patients underwent late coronary angiography. RESULTS: In group 1, the mean stent deployment pressure was 13.58±0.92 atm, and in the group 2 it was 18.15±1.66 atm. Stents implanted with moderate pressures (<FONT FACE=Symbol>&sup3;</FONT>12 to <16 atm) had a significantly smaller postprocedural minimal lumen diameter, compared to with those with higher pressure, with lesser acute gain (2.7± 0.4 mm vs 2.9±04 mm; p=0.004), but the late lumen loss (0,9±0,8 mm vs 0,9±0,6 mm) and the restenosis (22% vs. 17.1%) and target-vessel revascularization rates (9.8% vs 7.3%) were similar between the groups. CONCLUSION: During AMI stenting, the use of high pressures (<FONT FACE=Symbol>&sup3;</FONT>16 atm) did not cause a measurable improvement in late outcome, either in the late loss, its index, and the net gain, or in clinical and angiographic restenosis rates.
topic acute myocardial infarction
stents
restenosis
url http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0066-782X2003000300002
work_keys_str_mv AT luizalbertomattos influenceofballoonpressureinflationinpatientsundergoingprimarycoronarystentimplantationduringacutemyocardialinfarctionaquantitativecoronaryangiographyanalysis
AT amandagmrsousa influenceofballoonpressureinflationinpatientsundergoingprimarycoronarystentimplantationduringacutemyocardialinfarctionaquantitativecoronaryangiographyanalysis
AT aureachaves influenceofballoonpressureinflationinpatientsundergoingprimarycoronarystentimplantationduringacutemyocardialinfarctionaquantitativecoronaryangiographyanalysis
AT faustoferes influenceofballoonpressureinflationinpatientsundergoingprimarycoronarystentimplantationduringacutemyocardialinfarctionaquantitativecoronaryangiographyanalysis
AT ibraimpinto influenceofballoonpressureinflationinpatientsundergoingprimarycoronarystentimplantationduringacutemyocardialinfarctionaquantitativecoronaryangiographyanalysis
AT luiztanajura influenceofballoonpressureinflationinpatientsundergoingprimarycoronarystentimplantationduringacutemyocardialinfarctionaquantitativecoronaryangiographyanalysis
AT marinellacentemero influenceofballoonpressureinflationinpatientsundergoingprimarycoronarystentimplantationduringacutemyocardialinfarctionaquantitativecoronaryangiographyanalysis
AT alexandreabizaid influenceofballoonpressureinflationinpatientsundergoingprimarycoronarystentimplantationduringacutemyocardialinfarctionaquantitativecoronaryangiographyanalysis
AT anacseixas influenceofballoonpressureinflationinpatientsundergoingprimarycoronarystentimplantationduringacutemyocardialinfarctionaquantitativecoronaryangiographyanalysis
AT andreaabizaid influenceofballoonpressureinflationinpatientsundergoingprimarycoronarystentimplantationduringacutemyocardialinfarctionaquantitativecoronaryangiographyanalysis
AT galomaldonado influenceofballoonpressureinflationinpatientsundergoingprimarycoronarystentimplantationduringacutemyocardialinfarctionaquantitativecoronaryangiographyanalysis
AT rodolfostaico influenceofballoonpressureinflationinpatientsundergoingprimarycoronarystentimplantationduringacutemyocardialinfarctionaquantitativecoronaryangiographyanalysis
AT jeduardomrsousa influenceofballoonpressureinflationinpatientsundergoingprimarycoronarystentimplantationduringacutemyocardialinfarctionaquantitativecoronaryangiographyanalysis
_version_ 1725586942661230592