Development of a turn-to-turn fault detection method in the three-phase transformer's winding

THE PURPOSE. Reveal the regularities of turn-to-turn faults influence on to parameters of a three-phase network transformer in the disconnected transformer mode with the supply of control voltages and currents from an external source in the transformer linear operation. METHODS. To achieve the purpo...

Full description

Bibliographic Details
Main Authors: R. G. Mustafin, Yu. V. Piskovatsky, F. R. Sirazutdinov, D. F. Gubaev, A. N. Gavrilenko
Format: Article
Language:English
Published: Kazan State Power Engineering University 2021-05-01
Series:Известия высших учебных заведений: Проблемы энергетики
Subjects:
Online Access:https://www.energyret.ru/jour/article/view/1757
id doaj-7337401fc96a4f0b8aa6680eb1892588
record_format Article
spelling doaj-7337401fc96a4f0b8aa6680eb18925882021-07-28T13:16:33ZengKazan State Power Engineering UniversityИзвестия высших учебных заведений: Проблемы энергетики1998-99032021-05-01231465810.30724/1998-9903-2021-23-1-46-58725Development of a turn-to-turn fault detection method in the three-phase transformer's windingR. G. Mustafin0Yu. V. Piskovatsky1F. R. Sirazutdinov2D. F. Gubaev3A. N. Gavrilenko4Kazan State Power Engineering UniversityKazan State Power Engineering UniversityKazan State Power Engineering UniversityKazan State Power Engineering UniversityKazan State Power Engineering UniversityTHE PURPOSE. Reveal the regularities of turn-to-turn faults influence on to parameters of a three-phase network transformer in the disconnected transformer mode with the supply of control voltages and currents from an external source in the transformer linear operation. METHODS. To achieve the purpose, experimental studies were carried out on the power transformer (Trihal with a voltage of 20 / 0.4 kV) with an artificially created turn-to-turn fault, mathematical modeling and calculations of the three-phase transformer magnetic system parameters. RESULTS. Experimental measurements of the open circuit voltage were performed on the power transformer high voltage side by applying a three-phase positive sequence voltage to the transformer low voltage side. Similar measurements were carried out using a three-phase zero sequence current. The influence of the turn-to-turn fault on the magnetic system of the three-phase transformer with the application of voltages and currents of zero and direct sequences is investigated. A mathematical model of three-phase transformer magnetic system has been developed, which makes it possible to determine the change in the parameters of the transformer windings and to establish the relationship between the primary and secondary voltages and currents in conditions of the occurrence of а turn-to-turn fault. The parameters of the three-phase transformer magnetic system were calculated from the results of experimental measurements. CONCLUSION. An effective method for detecting turn-to-turn faults by measurements with the supply of zero sequence currents is proposed. A simplified model of the three-phase transformer magnetic system has been developed. This model allows us to qualitatively evaluate the changes in the transformer parameters when a turn-to-turn fault occurs. A model of turn-to-turn fault is proposed, which can be used to study the effect of turnto- turn fault on the transformer magnetic system.https://www.energyret.ru/jour/article/view/1757power transformersturn-to-turn faultsinsulation agingmodeling
collection DOAJ
language English
format Article
sources DOAJ
author R. G. Mustafin
Yu. V. Piskovatsky
F. R. Sirazutdinov
D. F. Gubaev
A. N. Gavrilenko
spellingShingle R. G. Mustafin
Yu. V. Piskovatsky
F. R. Sirazutdinov
D. F. Gubaev
A. N. Gavrilenko
Development of a turn-to-turn fault detection method in the three-phase transformer's winding
Известия высших учебных заведений: Проблемы энергетики
power transformers
turn-to-turn faults
insulation aging
modeling
author_facet R. G. Mustafin
Yu. V. Piskovatsky
F. R. Sirazutdinov
D. F. Gubaev
A. N. Gavrilenko
author_sort R. G. Mustafin
title Development of a turn-to-turn fault detection method in the three-phase transformer's winding
title_short Development of a turn-to-turn fault detection method in the three-phase transformer's winding
title_full Development of a turn-to-turn fault detection method in the three-phase transformer's winding
title_fullStr Development of a turn-to-turn fault detection method in the three-phase transformer's winding
title_full_unstemmed Development of a turn-to-turn fault detection method in the three-phase transformer's winding
title_sort development of a turn-to-turn fault detection method in the three-phase transformer's winding
publisher Kazan State Power Engineering University
series Известия высших учебных заведений: Проблемы энергетики
issn 1998-9903
publishDate 2021-05-01
description THE PURPOSE. Reveal the regularities of turn-to-turn faults influence on to parameters of a three-phase network transformer in the disconnected transformer mode with the supply of control voltages and currents from an external source in the transformer linear operation. METHODS. To achieve the purpose, experimental studies were carried out on the power transformer (Trihal with a voltage of 20 / 0.4 kV) with an artificially created turn-to-turn fault, mathematical modeling and calculations of the three-phase transformer magnetic system parameters. RESULTS. Experimental measurements of the open circuit voltage were performed on the power transformer high voltage side by applying a three-phase positive sequence voltage to the transformer low voltage side. Similar measurements were carried out using a three-phase zero sequence current. The influence of the turn-to-turn fault on the magnetic system of the three-phase transformer with the application of voltages and currents of zero and direct sequences is investigated. A mathematical model of three-phase transformer magnetic system has been developed, which makes it possible to determine the change in the parameters of the transformer windings and to establish the relationship between the primary and secondary voltages and currents in conditions of the occurrence of а turn-to-turn fault. The parameters of the three-phase transformer magnetic system were calculated from the results of experimental measurements. CONCLUSION. An effective method for detecting turn-to-turn faults by measurements with the supply of zero sequence currents is proposed. A simplified model of the three-phase transformer magnetic system has been developed. This model allows us to qualitatively evaluate the changes in the transformer parameters when a turn-to-turn fault occurs. A model of turn-to-turn fault is proposed, which can be used to study the effect of turnto- turn fault on the transformer magnetic system.
topic power transformers
turn-to-turn faults
insulation aging
modeling
url https://www.energyret.ru/jour/article/view/1757
work_keys_str_mv AT rgmustafin developmentofaturntoturnfaultdetectionmethodinthethreephasetransformerswinding
AT yuvpiskovatsky developmentofaturntoturnfaultdetectionmethodinthethreephasetransformerswinding
AT frsirazutdinov developmentofaturntoturnfaultdetectionmethodinthethreephasetransformerswinding
AT dfgubaev developmentofaturntoturnfaultdetectionmethodinthethreephasetransformerswinding
AT angavrilenko developmentofaturntoturnfaultdetectionmethodinthethreephasetransformerswinding
_version_ 1721275650907570176