Experimental Investigation and Performance Evaluation of a Closed Loop Pulsating Heat Pipe

Pulsating heat pipe (PHP) cooling is the new and emerging technique in the field of thermal management of electronics. In the present work, transient and steady state experiments are conducted on a single turn closed loop PHP. Evaporator and condenser wall temperatures are measured. Copper is used a...

Full description

Bibliographic Details
Main Authors: R. Naik, V Varadarajan, G Pundarika, K. R. Narasimha
Format: Article
Language:English
Published: Isfahan University of Technology 2013-01-01
Series:Journal of Applied Fluid Mechanics
Subjects:
Online Access:http://jafmonline.net/JournalArchive/download?file_ID=27016&issue_ID=212
id doaj-74c7677457ab4797ba0dbed5ef6978e9
record_format Article
spelling doaj-74c7677457ab4797ba0dbed5ef6978e92020-11-25T00:59:37ZengIsfahan University of Technology Journal of Applied Fluid Mechanics1735-36452013-01-0162267275.Experimental Investigation and Performance Evaluation of a Closed Loop Pulsating Heat PipeR. Naik0V Varadarajan1G Pundarika2K. R. Narasimha3Department of Mechanical Engineering, BM S College of Engineering, IndiaDepartment of Mechanical Engineering, BM S College of Engineering, IndiaPrincipal, Government Engineering College Ramanagara, IndiaJain UniversityPulsating heat pipe (PHP) cooling is the new and emerging technique in the field of thermal management of electronics. In the present work, transient and steady state experiments are conducted on a single turn closed loop PHP. Evaporator and condenser wall temperatures are measured. Copper is used as the capillary tube material in the evaporator and condenser sections with inner diameter of 1.95 mm and outer diameter of 3 mm. The total length of the closed loop pulsating heat pipe is 540 mm. The evaporator and condenser sections are 185 mm and 195 mm respectively. The experiments are conducted both in the horizontal as well as in vertical orientations for different heat loads varying from 9 W to 15 W in steps of 2 W. The PHP is tested with different working fluids viz., Acetone, Methanol and Ethanol for different fill ratios from 60% to 80% in steps of 10%. The performance parameters such as temperature difference between evaporator and condenser, thermal resistance and the overall heat transfer coefficient are evaluated. The experimental results demonstrate that Acetone is the better working fluid among the working fluids considered in terms of lower thermal resistance and higher heat transfer coefficient. The heat transfer characteristics of PHP are found to be better at a fill ratio of 60%. The single loop PHP is found to perform better with horizontal orientation for all heat loads, working fluids and fill ratios consideredhttp://jafmonline.net/JournalArchive/download?file_ID=27016&issue_ID=212Pulsating heat pipe Fill ratio Orientation Working fluids
collection DOAJ
language English
format Article
sources DOAJ
author R. Naik
V Varadarajan
G Pundarika
K. R. Narasimha
spellingShingle R. Naik
V Varadarajan
G Pundarika
K. R. Narasimha
Experimental Investigation and Performance Evaluation of a Closed Loop Pulsating Heat Pipe
Journal of Applied Fluid Mechanics
Pulsating heat pipe
Fill ratio
Orientation
Working fluids
author_facet R. Naik
V Varadarajan
G Pundarika
K. R. Narasimha
author_sort R. Naik
title Experimental Investigation and Performance Evaluation of a Closed Loop Pulsating Heat Pipe
title_short Experimental Investigation and Performance Evaluation of a Closed Loop Pulsating Heat Pipe
title_full Experimental Investigation and Performance Evaluation of a Closed Loop Pulsating Heat Pipe
title_fullStr Experimental Investigation and Performance Evaluation of a Closed Loop Pulsating Heat Pipe
title_full_unstemmed Experimental Investigation and Performance Evaluation of a Closed Loop Pulsating Heat Pipe
title_sort experimental investigation and performance evaluation of a closed loop pulsating heat pipe
publisher Isfahan University of Technology
series Journal of Applied Fluid Mechanics
issn 1735-3645
publishDate 2013-01-01
description Pulsating heat pipe (PHP) cooling is the new and emerging technique in the field of thermal management of electronics. In the present work, transient and steady state experiments are conducted on a single turn closed loop PHP. Evaporator and condenser wall temperatures are measured. Copper is used as the capillary tube material in the evaporator and condenser sections with inner diameter of 1.95 mm and outer diameter of 3 mm. The total length of the closed loop pulsating heat pipe is 540 mm. The evaporator and condenser sections are 185 mm and 195 mm respectively. The experiments are conducted both in the horizontal as well as in vertical orientations for different heat loads varying from 9 W to 15 W in steps of 2 W. The PHP is tested with different working fluids viz., Acetone, Methanol and Ethanol for different fill ratios from 60% to 80% in steps of 10%. The performance parameters such as temperature difference between evaporator and condenser, thermal resistance and the overall heat transfer coefficient are evaluated. The experimental results demonstrate that Acetone is the better working fluid among the working fluids considered in terms of lower thermal resistance and higher heat transfer coefficient. The heat transfer characteristics of PHP are found to be better at a fill ratio of 60%. The single loop PHP is found to perform better with horizontal orientation for all heat loads, working fluids and fill ratios considered
topic Pulsating heat pipe
Fill ratio
Orientation
Working fluids
url http://jafmonline.net/JournalArchive/download?file_ID=27016&issue_ID=212
work_keys_str_mv AT rnaik experimentalinvestigationandperformanceevaluationofaclosedlooppulsatingheatpipe
AT vvaradarajan experimentalinvestigationandperformanceevaluationofaclosedlooppulsatingheatpipe
AT gpundarika experimentalinvestigationandperformanceevaluationofaclosedlooppulsatingheatpipe
AT krnarasimha experimentalinvestigationandperformanceevaluationofaclosedlooppulsatingheatpipe
_version_ 1725217291805655040