Acute Coronary Syndrome after 17 Years of Bare Metal Stent Implantation: “Very” Very Late Stent Thrombosis

Very late stent thrombosis (VLST) is a catastrophic and life-threatening complication after percutaneous coronary intervention which presents as an acute coronary syndrome with significantly high mortality and morbidity. VLST is a rare entity with drug-eluting stents and even rarer with bare metal s...

Full description

Bibliographic Details
Main Authors: Raghavendra Rao K, S. Reddy, J. R. Kashyap, K. Vikas, Hithesh Reddy, Vadivelu Ramalingam
Format: Article
Language:English
Published: Hindawi Limited 2020-01-01
Series:Case Reports in Cardiology
Online Access:http://dx.doi.org/10.1155/2020/9628719
Description
Summary:Very late stent thrombosis (VLST) is a catastrophic and life-threatening complication after percutaneous coronary intervention which presents as an acute coronary syndrome with significantly high mortality and morbidity. VLST is a rare entity with drug-eluting stents and even rarer with bare metal stents. The exact pathophysiologic mechanism of VLST after BMS implantation is not known although various mechanisms have been proposed. Recently, in-stent neoatherosclerosis with intimal plaque rupture has been proposed as a potential mechanism of VLST after BMS. We report a rare case of VLST occurring 17 years after BMS implantation with angiographic and intravascular imaging evidence which provides insight into the mechanisms of VLST.