Are measurements of systolic myocardial velocities and displacement with colour and spectral Tissue Doppler compatible?

<p>Abstract</p> <p>Background</p> <p>Tissue Doppler (TD) in pulsed mode (spectral TD) and colour TD are the two modalities today available in tissue velocity echocardiography (TVE). Previous studies have shown poor agreement between these two methods when measuring myoc...

Full description

Bibliographic Details
Main Authors: Winter Reidar, Shahgaldi Kambiz, Nyktari Evangelia, Shala Arben, Manouras Aristomenis, Vardas Panagiotis, Brodin Lars-Åke, Nowak Jacek
Format: Article
Language:English
Published: BMC 2009-06-01
Series:Cardiovascular Ultrasound
Online Access:http://www.cardiovascularultrasound.com/content/7/1/29
id doaj-74ea5926d321483b8fff628db0c9b71d
record_format Article
spelling doaj-74ea5926d321483b8fff628db0c9b71d2020-11-24T20:44:19ZengBMCCardiovascular Ultrasound1476-71202009-06-01712910.1186/1476-7120-7-29Are measurements of systolic myocardial velocities and displacement with colour and spectral Tissue Doppler compatible?Winter ReidarShahgaldi KambizNyktari EvangeliaShala ArbenManouras AristomenisVardas PanagiotisBrodin Lars-ÅkeNowak Jacek<p>Abstract</p> <p>Background</p> <p>Tissue Doppler (TD) in pulsed mode (spectral TD) and colour TD are the two modalities today available in tissue velocity echocardiography (TVE). Previous studies have shown poor agreement between these two methods when measuring myocardial velocities and displacement. In this study, the concordance between the myocardial velocity and displacement measurements using colour TD and different spectral TD procedures was evaluated.</p> <p>Methods</p> <p>Left ventricular (LV) longitudinal systolic myocardial velocities and displacement during ejection period were quantified at the basal septal and lateral wall in 24 healthy individuals (4 women and 20 men, 34 ± 12 years) using spectral TD, colour TD and M-mode recordings. Mean, maximal and minimal spectral TD systolic velocities and the corresponding displacement values were obtained by measurements at the outer and inner borders of the spectral velocity signal. The results were then compared with those obtained with the two other modalities used.</p> <p>Results</p> <p>Systolic myocardial velocities derived from mean spectral TD frequencies were highly concordant with corresponding colour TD measurements (mean difference 0.10 ± 0.54 cm/sec in septal and 0.09 ± 0.97 cm/sec in lateral wall). Similarly, the agreement between spectral and colour TD (mean difference 0.22 ± 0.74 mm in septal and 0.02 ± 0.86 mm in lateral wall) as well as M-mode was good when mean spectral velocities were temporally integrated and the results did not differ statistically. Conversely, displacement values from the inner or outer border of the spectral signal differed significantly from values obtained with colour TD and M-mode (p < 0.001, in both cases).</p> <p>Conclusion</p> <p>LV systolic myocardial measurements based on mean spectral TD frequencies are highly concordant with those provided by colour TD and M-mode. Hence, in order to maintain compatibility of the results, the use of this particular spectral TD procedure should be advocated in clinical praxis.</p> http://www.cardiovascularultrasound.com/content/7/1/29
collection DOAJ
language English
format Article
sources DOAJ
author Winter Reidar
Shahgaldi Kambiz
Nyktari Evangelia
Shala Arben
Manouras Aristomenis
Vardas Panagiotis
Brodin Lars-Åke
Nowak Jacek
spellingShingle Winter Reidar
Shahgaldi Kambiz
Nyktari Evangelia
Shala Arben
Manouras Aristomenis
Vardas Panagiotis
Brodin Lars-Åke
Nowak Jacek
Are measurements of systolic myocardial velocities and displacement with colour and spectral Tissue Doppler compatible?
Cardiovascular Ultrasound
author_facet Winter Reidar
Shahgaldi Kambiz
Nyktari Evangelia
Shala Arben
Manouras Aristomenis
Vardas Panagiotis
Brodin Lars-Åke
Nowak Jacek
author_sort Winter Reidar
title Are measurements of systolic myocardial velocities and displacement with colour and spectral Tissue Doppler compatible?
title_short Are measurements of systolic myocardial velocities and displacement with colour and spectral Tissue Doppler compatible?
title_full Are measurements of systolic myocardial velocities and displacement with colour and spectral Tissue Doppler compatible?
title_fullStr Are measurements of systolic myocardial velocities and displacement with colour and spectral Tissue Doppler compatible?
title_full_unstemmed Are measurements of systolic myocardial velocities and displacement with colour and spectral Tissue Doppler compatible?
title_sort are measurements of systolic myocardial velocities and displacement with colour and spectral tissue doppler compatible?
publisher BMC
series Cardiovascular Ultrasound
issn 1476-7120
publishDate 2009-06-01
description <p>Abstract</p> <p>Background</p> <p>Tissue Doppler (TD) in pulsed mode (spectral TD) and colour TD are the two modalities today available in tissue velocity echocardiography (TVE). Previous studies have shown poor agreement between these two methods when measuring myocardial velocities and displacement. In this study, the concordance between the myocardial velocity and displacement measurements using colour TD and different spectral TD procedures was evaluated.</p> <p>Methods</p> <p>Left ventricular (LV) longitudinal systolic myocardial velocities and displacement during ejection period were quantified at the basal septal and lateral wall in 24 healthy individuals (4 women and 20 men, 34 ± 12 years) using spectral TD, colour TD and M-mode recordings. Mean, maximal and minimal spectral TD systolic velocities and the corresponding displacement values were obtained by measurements at the outer and inner borders of the spectral velocity signal. The results were then compared with those obtained with the two other modalities used.</p> <p>Results</p> <p>Systolic myocardial velocities derived from mean spectral TD frequencies were highly concordant with corresponding colour TD measurements (mean difference 0.10 ± 0.54 cm/sec in septal and 0.09 ± 0.97 cm/sec in lateral wall). Similarly, the agreement between spectral and colour TD (mean difference 0.22 ± 0.74 mm in septal and 0.02 ± 0.86 mm in lateral wall) as well as M-mode was good when mean spectral velocities were temporally integrated and the results did not differ statistically. Conversely, displacement values from the inner or outer border of the spectral signal differed significantly from values obtained with colour TD and M-mode (p < 0.001, in both cases).</p> <p>Conclusion</p> <p>LV systolic myocardial measurements based on mean spectral TD frequencies are highly concordant with those provided by colour TD and M-mode. Hence, in order to maintain compatibility of the results, the use of this particular spectral TD procedure should be advocated in clinical praxis.</p>
url http://www.cardiovascularultrasound.com/content/7/1/29
work_keys_str_mv AT winterreidar aremeasurementsofsystolicmyocardialvelocitiesanddisplacementwithcolourandspectraltissuedopplercompatible
AT shahgaldikambiz aremeasurementsofsystolicmyocardialvelocitiesanddisplacementwithcolourandspectraltissuedopplercompatible
AT nyktarievangelia aremeasurementsofsystolicmyocardialvelocitiesanddisplacementwithcolourandspectraltissuedopplercompatible
AT shalaarben aremeasurementsofsystolicmyocardialvelocitiesanddisplacementwithcolourandspectraltissuedopplercompatible
AT manourasaristomenis aremeasurementsofsystolicmyocardialvelocitiesanddisplacementwithcolourandspectraltissuedopplercompatible
AT vardaspanagiotis aremeasurementsofsystolicmyocardialvelocitiesanddisplacementwithcolourandspectraltissuedopplercompatible
AT brodinlarsake aremeasurementsofsystolicmyocardialvelocitiesanddisplacementwithcolourandspectraltissuedopplercompatible
AT nowakjacek aremeasurementsofsystolicmyocardialvelocitiesanddisplacementwithcolourandspectraltissuedopplercompatible
_version_ 1716817623198466048