Multi-modes Fiber Ring Laser Sensor Combining One Fiber Bragg Grating Reflector

A multi-longitudinal-mode fiber ring laser sensor is firstly proposed and experimentally demonstrated. Beat frequencies between any two longitudinal modes are used as sensing signal. The core component of the system is a multi-longitudinal-mode fiber ring cavity laser sensor based on beat frequency...

Full description

Bibliographic Details
Main Authors: Jintao ZHANG, Youlong YU, Yunlong ZHANG, Kun LI, Xiangchun XI
Format: Article
Language:English
Published: IFSA Publishing, S.L. 2014-01-01
Series:Sensors & Transducers
Subjects:
Online Access:http://www.sensorsportal.com/HTML/DIGEST/january_2014/Vol_162/P_1746.pdf
id doaj-750b8bd55f124532ae6d820642f5c2f9
record_format Article
spelling doaj-750b8bd55f124532ae6d820642f5c2f92020-11-24T23:39:25ZengIFSA Publishing, S.L.Sensors & Transducers2306-85151726-54792014-01-0116213841Multi-modes Fiber Ring Laser Sensor Combining One Fiber Bragg Grating ReflectorJintao ZHANG0Youlong YU1Yunlong ZHANG2 Kun LI3Xiangchun XI4 School of Instrument Science and Optic-Electronics Engineering, Heifei Univeristy of Technology, Hefei, 230009, China School of Instrument Science and Optic-Electronics Engineering, Heifei Univeristy of Technology, Hefei, 230009, ChinaInstitute of Fiber Optics, Heilongjiang University, Harbin 150080, P. R. ChinaInstitute of Fiber Optics, Heilongjiang University, Harbin 150080, P. R. ChinaInstitute of Fiber Optics, Heilongjiang University, Harbin 150080, P. R. ChinaA multi-longitudinal-mode fiber ring laser sensor is firstly proposed and experimentally demonstrated. Beat frequencies between any two longitudinal modes are used as sensing signal. The core component of the system is a multi-longitudinal-mode fiber ring cavity laser sensor based on beat frequency demodulation method. The theory of beat signal generation and strain measurement are discussed in detail. The beat frequency shift caused by the strain applied on the cavity is demodulated using spectrum analyze. Experimental results shown the strain accuracy of the laser sensor is 1.3 ?? and the resolution of the strain is 1.6 kHz/?? at measuring frequency of 2019 MHz. The noise effect of self-heating in the cavity is 0.149 kHz/mW. The SNR of the sensor system is higher than 61 dB. The simple laser sensor has ultra-stable signal. The usage of only one fiber laser and one demodulation system makes the system simple, cost-effective and portable. http://www.sensorsportal.com/HTML/DIGEST/january_2014/Vol_162/P_1746.pdfFiber optics sensorsLaserBeat frequency modulatedMulti-longitudinal-modeFiber Bragg grating.
collection DOAJ
language English
format Article
sources DOAJ
author Jintao ZHANG
Youlong YU
Yunlong ZHANG
Kun LI
Xiangchun XI
spellingShingle Jintao ZHANG
Youlong YU
Yunlong ZHANG
Kun LI
Xiangchun XI
Multi-modes Fiber Ring Laser Sensor Combining One Fiber Bragg Grating Reflector
Sensors & Transducers
Fiber optics sensors
Laser
Beat frequency modulated
Multi-longitudinal-mode
Fiber Bragg grating.
author_facet Jintao ZHANG
Youlong YU
Yunlong ZHANG
Kun LI
Xiangchun XI
author_sort Jintao ZHANG
title Multi-modes Fiber Ring Laser Sensor Combining One Fiber Bragg Grating Reflector
title_short Multi-modes Fiber Ring Laser Sensor Combining One Fiber Bragg Grating Reflector
title_full Multi-modes Fiber Ring Laser Sensor Combining One Fiber Bragg Grating Reflector
title_fullStr Multi-modes Fiber Ring Laser Sensor Combining One Fiber Bragg Grating Reflector
title_full_unstemmed Multi-modes Fiber Ring Laser Sensor Combining One Fiber Bragg Grating Reflector
title_sort multi-modes fiber ring laser sensor combining one fiber bragg grating reflector
publisher IFSA Publishing, S.L.
series Sensors & Transducers
issn 2306-8515
1726-5479
publishDate 2014-01-01
description A multi-longitudinal-mode fiber ring laser sensor is firstly proposed and experimentally demonstrated. Beat frequencies between any two longitudinal modes are used as sensing signal. The core component of the system is a multi-longitudinal-mode fiber ring cavity laser sensor based on beat frequency demodulation method. The theory of beat signal generation and strain measurement are discussed in detail. The beat frequency shift caused by the strain applied on the cavity is demodulated using spectrum analyze. Experimental results shown the strain accuracy of the laser sensor is 1.3 ?? and the resolution of the strain is 1.6 kHz/?? at measuring frequency of 2019 MHz. The noise effect of self-heating in the cavity is 0.149 kHz/mW. The SNR of the sensor system is higher than 61 dB. The simple laser sensor has ultra-stable signal. The usage of only one fiber laser and one demodulation system makes the system simple, cost-effective and portable.
topic Fiber optics sensors
Laser
Beat frequency modulated
Multi-longitudinal-mode
Fiber Bragg grating.
url http://www.sensorsportal.com/HTML/DIGEST/january_2014/Vol_162/P_1746.pdf
work_keys_str_mv AT jintaozhang multimodesfiberringlasersensorcombiningonefiberbragggratingreflector
AT youlongyu multimodesfiberringlasersensorcombiningonefiberbragggratingreflector
AT yunlongzhang multimodesfiberringlasersensorcombiningonefiberbragggratingreflector
AT kunli multimodesfiberringlasersensorcombiningonefiberbragggratingreflector
AT xiangchunxi multimodesfiberringlasersensorcombiningonefiberbragggratingreflector
_version_ 1725513610317266944