The Effects of Nitrogen Gas on Microstructural and Mechanical Properties of TIG Welded S32205 Duplex Stainless Steel

Duplex stainless steels are gaining greater interest due to their increasing amounts of application fields. Accordingly, there is a need for awareness of problems associated with improper microstructural distributions such as δ-ferrite (delta-ferrite), austenite and other important intermetallic pha...

Full description

Bibliographic Details
Main Authors: Aziz Barış Başyiğit, Adem Kurt
Format: Article
Language:English
Published: MDPI AG 2018-04-01
Series:Metals
Subjects:
Online Access:http://www.mdpi.com/2075-4701/8/4/226
id doaj-75962b67172345f38ae087562dc9466b
record_format Article
spelling doaj-75962b67172345f38ae087562dc9466b2020-11-24T21:04:40ZengMDPI AGMetals2075-47012018-04-018422610.3390/met8040226met8040226The Effects of Nitrogen Gas on Microstructural and Mechanical Properties of TIG Welded S32205 Duplex Stainless SteelAziz Barış Başyiğit0Adem Kurt1Faculty of Engineering, Metallurgical and Material Engineering Department, Kırıkkale University, 71450 Kırıkkale, TurkeyFaculty of Technology, Metallurgical and Material Engineering Department, Gazi University, 06500 Ankara, TurkeyDuplex stainless steels are gaining greater interest due to their increasing amounts of application fields. Accordingly, there is a need for awareness of problems associated with improper microstructural distributions such as δ-ferrite (delta-ferrite), austenite and other important intermetallic phases that may form in these steel weldments. Since δ-ferrite versus austenite ratio profoundly influences corrosion and mechanical properties, optimum δ-ferrite ratios must be kept approximately within 35–65 vol % and balance austenite to maintain satisfactory corrosion and mechanical properties on welding of these steels. Cooling rates of welds and alloying elements in base metal are the major factors that determine the final microstructure of these steels. In this work, 3 mm thickness of 2205 duplex stainless-steel plates were TIG (Tungsten Inert Gas) welded with various amounts of nitrogen gas added to argon shielding gas. Specimens were joined within the same welding parameters and cooling conditions. As nitrogen is a potential austenite stabilizer and an interstitial solid solution hardener, the effects of nitrogen on mechanical properties such as hardness profiles, grain sizes and microstructural modifications are investigated thoroughly by changing the welding shielding gas compositions. Increasing the nitrogen content in argon shielding gas also increases the amount of austenitic phase while δ-ferrite ratios decreases. Nitrogen spherodized the grains of austenitic structure much more than observed in δ-ferrite. The strength values of specimens that welded with the addition of nitrogen gas into the argon shielding gas are increased more in both austenitic and delta-ferritic structure as compared to specimens that welded with plain argon shielding gas. The addition of 1 vol % of nitrogen gas into argon shielding gas provided the optimum phase balance of austenite and δ-ferrite in S32205 duplex stainless-steel TIG-welded specimens.http://www.mdpi.com/2075-4701/8/4/226duplex stainless steelsTIG weldingnitrogen gas effects
collection DOAJ
language English
format Article
sources DOAJ
author Aziz Barış Başyiğit
Adem Kurt
spellingShingle Aziz Barış Başyiğit
Adem Kurt
The Effects of Nitrogen Gas on Microstructural and Mechanical Properties of TIG Welded S32205 Duplex Stainless Steel
Metals
duplex stainless steels
TIG welding
nitrogen gas effects
author_facet Aziz Barış Başyiğit
Adem Kurt
author_sort Aziz Barış Başyiğit
title The Effects of Nitrogen Gas on Microstructural and Mechanical Properties of TIG Welded S32205 Duplex Stainless Steel
title_short The Effects of Nitrogen Gas on Microstructural and Mechanical Properties of TIG Welded S32205 Duplex Stainless Steel
title_full The Effects of Nitrogen Gas on Microstructural and Mechanical Properties of TIG Welded S32205 Duplex Stainless Steel
title_fullStr The Effects of Nitrogen Gas on Microstructural and Mechanical Properties of TIG Welded S32205 Duplex Stainless Steel
title_full_unstemmed The Effects of Nitrogen Gas on Microstructural and Mechanical Properties of TIG Welded S32205 Duplex Stainless Steel
title_sort effects of nitrogen gas on microstructural and mechanical properties of tig welded s32205 duplex stainless steel
publisher MDPI AG
series Metals
issn 2075-4701
publishDate 2018-04-01
description Duplex stainless steels are gaining greater interest due to their increasing amounts of application fields. Accordingly, there is a need for awareness of problems associated with improper microstructural distributions such as δ-ferrite (delta-ferrite), austenite and other important intermetallic phases that may form in these steel weldments. Since δ-ferrite versus austenite ratio profoundly influences corrosion and mechanical properties, optimum δ-ferrite ratios must be kept approximately within 35–65 vol % and balance austenite to maintain satisfactory corrosion and mechanical properties on welding of these steels. Cooling rates of welds and alloying elements in base metal are the major factors that determine the final microstructure of these steels. In this work, 3 mm thickness of 2205 duplex stainless-steel plates were TIG (Tungsten Inert Gas) welded with various amounts of nitrogen gas added to argon shielding gas. Specimens were joined within the same welding parameters and cooling conditions. As nitrogen is a potential austenite stabilizer and an interstitial solid solution hardener, the effects of nitrogen on mechanical properties such as hardness profiles, grain sizes and microstructural modifications are investigated thoroughly by changing the welding shielding gas compositions. Increasing the nitrogen content in argon shielding gas also increases the amount of austenitic phase while δ-ferrite ratios decreases. Nitrogen spherodized the grains of austenitic structure much more than observed in δ-ferrite. The strength values of specimens that welded with the addition of nitrogen gas into the argon shielding gas are increased more in both austenitic and delta-ferritic structure as compared to specimens that welded with plain argon shielding gas. The addition of 1 vol % of nitrogen gas into argon shielding gas provided the optimum phase balance of austenite and δ-ferrite in S32205 duplex stainless-steel TIG-welded specimens.
topic duplex stainless steels
TIG welding
nitrogen gas effects
url http://www.mdpi.com/2075-4701/8/4/226
work_keys_str_mv AT azizbarısbasyigit theeffectsofnitrogengasonmicrostructuralandmechanicalpropertiesoftigweldeds32205duplexstainlesssteel
AT ademkurt theeffectsofnitrogengasonmicrostructuralandmechanicalpropertiesoftigweldeds32205duplexstainlesssteel
AT azizbarısbasyigit effectsofnitrogengasonmicrostructuralandmechanicalpropertiesoftigweldeds32205duplexstainlesssteel
AT ademkurt effectsofnitrogengasonmicrostructuralandmechanicalpropertiesoftigweldeds32205duplexstainlesssteel
_version_ 1716770341122998272